Ir Receiver Connection - Russound UNO-TS2 Instruction Manual

Hide thumbs Also See for UNO-TS2:
Table of Contents

Advertisement

The UNO-TS2 has an External IR Receiver In ter-
minal for connecting an external IR Receiver
such as the Russound 858, SaphIR 862 Eye, or
SaphIR 860 Phantom.
If you plan to use an additional IR receiver with
the UNO-TS2, first determine the location of the
IR receiver, then measure the distance from the
intended location to the UNO touchscreen loca-
tion. Incorporating optional IR receivers will
require additional wire. Consult the selected IR
Back of
858 IR
Receiver
receiver model's manual for the specific wire
needs.
Use 2 twisted pair wire with one pair connecting
GND (GROUND) and IR (SIGNAL) and the other
pair connecting ST (STATUS) and V+ (+12VDC).
Connect the shield or drain to ground at the
UNO-TS2 only.
Note: Installing an external IR receiver and
UNO-TS2 in the same room, with visibility to
both may cause poor IR performance.
RNET
NEWMARKET, NH USA
+12V
+12V
GND
STATUS IN
UNO-TS2
GND
IR OUT
COM A
COM B
EXTERNAL IR
RECEIVER IN
DESIGNED IN USA MADE IN KOREA
3
110 PUNCHDOWN CONNECTOR - Termination for
1
RNET CAT-5 connection between the UNO-TS2
Keypad and the CAV6.6/CAM6.6 controller
RESET BUTTON - Reset touchscreen after
2
firmware updates
(same as reset button on front)
EXTERNAL IR RECEIVER IN CONNECTOR -
3
Connection for an external IR Receiver
INSTALLER GUIDE
UNO-TS2 IR Receiver Connection
BR
BR/W
GR
GR/W
OR
OR/W
BL
BL/W
Back of
UNO-TS2
1
2
19

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Russound UNO-TS2

Table of Contents