Introduction and Inspection
Product Inspection
Inspect the product carefully for damage during shipping, checking panel switches and connectors.
Accessories Included
Lists the items included with the product, such as manuals, batteries, and cables.
Safety and Usage Notes
Safety Notes and Symbols
Details safety standards, warnings, and symbols used in the manual for safe operation.
Notes on Product Use
Provides crucial precautions for safe operation, including voltage limits and environmental conditions.
Preliminary Checks
Verify the product's normal operation before first use and contact dealer if damage is found.
Product Overview and Controls
Major Product Features
Highlights key features like color LCD, measurement functions, trigger capabilities, and connectivity.
Identification of Controls and Indicators
Locates and describes all front panel buttons, terminals, and indicators for user interaction.
Product Connectivity Ports
Details the PC card slot, RS-232C terminal, and logic probe connectors on the device.
Installation and Preparation
Product Installation Environment
Specifies optimal ambient conditions and locations to avoid for product installation.
Power Supply and Ground Connection
Explains how to connect the AC adapter and install batteries for power supply.
Connecting Input and Accessory Cables
Details the connection procedures for various cords, probes, and external units.
Basic Button Operation
Screen Navigation and Display Buttons
Describes buttons for switching between different display screens like Environment and Waveform.
Input Channel Configuration Buttons
Explains buttons for setting voltage axis, coupling, and other input parameters for each channel.
Measurement Start and Stop Controls
Details the START and STOP buttons for initiating and terminating measurements.
Memory Recorder Function Overview
Memory Recorder Features
Highlights features like high-speed saving, multi-channel recording, and numerical calculation functions.
Memory Recorder Operation Sequence
Provides a step-by-step guide for setting up and performing measurements using the memory recorder.
Setting Items for Memory Recorder
Details how to configure function mode, time axis, recording length, and other parameters.
Recorder and RMS Recorder Functions
Recorder Function Overview
Describes the real-time display, continuous recording, and waveform storage capabilities.
RMS Recorder Function Overview
Explains RMS value recording for power supplies and DC signals, including instantaneous waveform capture.
Setting Items for Recorder and RMS
Covers configuration for function mode, time axis, recording length, and display layout.
Input Channel Settings
Channel Setting Overview
Details settings available for analog and logic channels, including display and scaling.
Operation Sequence for Channel Setup
Guides users through setting waveform color, axis range, coupling, and filters for channels.
Waveform Display Color and Graph Settings
Explains how to set the display color and position for waveforms on the channel screen.
Voltage Axis Range and Input Coupling
Covers setting the voltage scale per division and selecting input coupling (DC, GND, CLAMP).
Trigger Functions
Trigger Function Overview
Defines trigger terms and lists available trigger sources like analog, logic, and external triggers.
Trigger Mode and Pre-trigger Settings
Explains trigger modes (Single, Repeat, Auto) and pre-trigger functionality for waveform capture.
Internal Trigger Types
Details various internal trigger types including Level, Window, Voltage Drop, and Waveform Detection triggers.
Timer and External Trigger Functions
Describes setting timed triggers and using external signals for synchronization and triggering.
Waveform Screen Operation
Waveform Display and Measurement Settings
Covers setting input channels, trigger conditions, and display parameters on the waveform screen.
Using A/B Cursors for Analysis
Explains how to use cursors to measure time difference, frequency, and voltage on waveforms.
Waveform Scrolling and Zooming
Details how to scroll waveforms horizontally and adjust magnification/compression ratios.
System Settings
Environment Screen Settings
Configures general system parameters like START button activation, backup, and display settings.
Setting Screen for Saving Configurations
Allows saving, loading, deleting, and autosetting of system configurations.
Initialize Screen for System Reset
Covers setting the clock, clearing data, performing system reset, and self-checks.
Printout of Measurement Data
Printing Procedures Overview
Outlines printing formats (waveform, numeric) and methods (manual, auto, real-time).
Printer Environment and Comment Settings
Details print settings like grid type, time value, list/gauge, channel markers, and density.
Manual, Auto, and Real-Time Printing
Explains how to perform manual printing, automatic printing, and real-time continuous printing.
Storing the Measurement Data
PC Card Usage and Options
Describes PC card types, capacity, data formats (binary, text), and auto-setup.
File Screen Operations
Covers loading, saving, deleting, renaming files, creating directories, and formatting PC cards.
File Configuration and Sorting
Details settings for sorting files on the PC card and performing self-checks.
Communication Function
RS-232C Interface Overview
Explains the RS-232C serial communication standard and its application for remote control.
Connecting and Setting the RS-232C Interface
Provides instructions for connecting the cable and configuring communication parameters.
Specifications
General Product Specifications
Lists basic specifications including measurement functions, channels, memory, sampling rate, and power.
Trigger System Specifications
Details trigger methods, modes, sources, types, filter settings, and timing.
Memory Recorder Function Specifications
Provides specific technical details for the Memory Recorder function's time axis, storage, and printing.
Logic and Analog Inputs
Logic Input Connections and Probes
Explains how to connect logic probes and their specifications for measuring digital signals.
Analog Input Specifications
Details analog input measurement ranges, accuracy, frequency response, and input voltage limits.
Maintenance and Service
Changing the Product Battery
Provides instructions for safely replacing the device's batteries and handling battery packs.
Troubleshooting Common Issues
Offers solutions for common problems like screen not lighting, no waveform, or faint printouts.
Appendix 1: Messages
Error Message Reference
Lists and explains error codes displayed during operation and their remedies.
Warning Message Reference
Lists and explains warning messages and how they can be cleared.
Appendix 3: WaveViewer Software
WaveViewer System Requirements and Installation
Details the PC system requirements and the procedure for installing the waveform viewer software.
Using the Waveform Viewer Application
Explains how to start the viewer, use the toolbar, and interpret the status bar information.
Converting Waveform Data to CSV Format
Guides on converting displayed waveform data into CSV files for spreadsheet analysis.