Summarization of Contents

Calibration Preparation
Introduction to Calibration
Overview of calibration period, methods, and environment requirements.
General Equipment Required
Lists essential equipment for calibrating the 3000A series calibrators.
Optional Equipment
Mentions additional equipment needed for full calibration.
Specific Equipment Requirements
Oscilloscope Option Equipment
Lists equipment needed for calibrating the Oscilloscope output function.
Power Option Equipment
Lists equipment needed for calibrating Power output functions.
Managing Calibration Password
Changing the Calibration Password
Step-by-step guide to changing the calibrator's password.
Set New Password
Procedure for setting a new calibration password on the instrument.
Manual Calibration Guide
Front Panel Controls Overview
Explains the function of various controls on the calibrator's front panel.
Entering Calibration Mode
Steps to navigate the calibrator to enter calibration mode.
Exiting Calibration Mode
Procedure for safely ending the calibration program.
Calibration Parameters Selection
How to select different calibration parameters after entering calibration mode.
Calibration Connections and Setup
Output Connections Diagram
Illustrates how to connect the calibrator outputs for calibration.
Calibration of Measurement Ranges
D.C. Voltage Calibration
Detailed procedure for calibrating DC Voltage outputs.
D.C. Current Calibration
Steps to calibrate the DC Current outputs of the calibrator.
A.C. Voltage Calibration
Procedure for calibrating AC Voltage outputs.
A.C. Current Calibration
Steps to calibrate the AC Current outputs.
2-Wire Resistance Calibration
Procedure for calibrating the 2-wire resistance output.
4-Wire Resistance Calibration
Procedure for calibrating the 4-wire resistance output.
Active Resistance Calibration
Steps to calibrate the Active Resistance output.
Capacitance Calibration
Procedure for calibrating the Capacitance outputs.
Inductance Calibration
Steps to calibrate the Inductance outputs.
PRT (Temperature) Calibration
Procedure for calibrating the PRT (temperature) output.
Oscilloscope Amplitude Calibration
Steps to calibrate the Oscilloscope Amplitude output.
Oscilloscope Bandwidth Calibration
Procedure for calibrating the Oscilloscope Bandwidth output.
AC Power Output Calibration
Steps to calibrate the AC Power output function.
DC Power Output Calibration
Procedure for calibrating the DC Power output function.
A/D Input Calibration
Steps to calibrate the A/D Input function.