Drive Cache: Specify the drive cache policy:
◊ NoChange: Leave the current drive cache policy unchanged. This is
the default.
◊ Enable: Enable the drive cache.
◊ Disable: Disable the drive cache.
Disable BGI: Specify the background initialization status:
◊ No: Leave background initialization enabled. This means that a
new configuration can be initialized in the background while you use
WebBIOS to do other configuration tasks. This is the default.
◊ Yes: Select Yes if you do not want to allow background initializations
for configurations on this controller.
Select Size: Specify the size of the virtual drive in megabytes. Normally,
this would be the full size for RAID 0 shown in the Configuration panel
on the right. You may specify a smaller size if you want to create other
virtual drives on the same drive group.
Click Accept to accept the changes to the virtual drive definition, or click
7.
Reclaim to return to the previous settings.
Click Yes to confirm to select the Write Through mode.
8.
Click Next when you are finished
9.
defining virtual drives. The
configuration preview screen
appears, as shown in the right figure.
10. Check the information in the
configuration preview.
11. If the virtual drive configuration is
acceptable, click Accept to save the
configuration. Otherwise, click Back
to return to the previous screens and
change the configuration.
12. If you accept the configuration, click Yes at the prompt to save the
configuration.
13. Click Yes at the prompt to start initialization.