TO ADJUST
THE CLEARANCE
BETWEEN
THE NEEDLES
AND
THE FIXED NEEDLE
GUARD
CORRECT SETTING:
THE CLEARANCE BETWEEN NEEDLE AND THE FIXED NEEDLE GUARD SHOULD BE 0.1 TO 0.4 MM.
TO ADJUST:
1. REMOVE THE PRESSER FOOT AND THE NEEDLE PLATE AND LOWER THE NEEDLE TO ITS
LOWEST POSITION.
2. LOOSEN SETSCREW (A) AND ADJUSTTHE POSITION OFTHE FIXED NEEDLE GUARD.
3. TIGHTEN SETSCREW (A).
4. ATTACH THE NEEDLE PLATE AND THE PRESSER FOOT.
NEEDLE PLATE SETTING KNOB
SHOULD BE SET AT "S"
THE CLEARANCE BETWEEN THE
NEEDLE
AND FIXED NEEDLE GUARD
FIXED NEEDLE GUARD
CHAINING FINGER
O.E!OUO o \
/
FIXED NEEDLE GUARD
SETSC_,
NEEDLE #14
NEEDLE PLATE SETTING
KNOB SHOULD BE SET AT
_S _
NEEDLE PLATE SETTING KNOB