Additional Drivers; Miniroot - HP Dl180 - G6 E5504 2X2gb 4Lff Svr Deployment Manual

Sun solaris 10 deployment guide for hp proliant servers
Hide thumbs Also See for Dl180 - G6 E5504 2X2gb 4Lff Svr:
Table of Contents

Advertisement

Additional drivers

Every new ProLiant generation is enhanced with newer device technologies, and ProLiant servers often
include some devices specific to HP. Frequently, drivers for one or more devices are not available on
the Solaris media. The following section describes the current set of drivers not available on the
Solaris media.
The following drivers are available for download from
Drivers" page associated with each ProLiant server model:
Smart Array Driver—Most ProLiant servers are equipped with an HP Smart Array RAID controller.
This driver for this RAID controller is not currently included on the Solaris media. To install Solaris
to disks attached to the controller, the cpqary3 driver must be loadable at installation time. To
boot from the controller, the driver must be installed on the system during deployment. For more
information, see "Miniroot" and "JumpStart."
NOTE:
Update (DU) for Solaris (x86) 10."
Broadcom NetXtreme II driver—Current ProLiant generations use newer Broadcom NIC chipsets
for embedded NICs. The driver for these chipsets does not currently ship on the Solaris media.
To perform network deployments using these NICs, the bnx driver must be loadable at
installation time. To use the NICs after installation is complete, the driver must be installed on the
system. For more information, see "Miniroot" and "JumpStart."
The following NIC models require the bnx driver:
NC370x
NC371x
NC373x
NC374x
NC380x

Miniroot

All device drivers required during installation, such as the disk driver for targeted storage, must be
loaded into the miniroot. You can load the device drivers manually at run-time. Alternatively, you can
install the driver into the miniroot before booting the client for automated deployments or ease of
interactive installations.
When loading device drivers into the miniroot, follow these guidelines:
For most ProLiant servers, the Smart Array driver, cpqary3, is installed into the miniroot so that
the Solaris software can be installed onto disks attached to a Smart Array controller.
For network-based deployments, the miniroot must have a driver for the network interface to be
used. For current ProLiant generations, the Broadcom NetXtreme II driver, bnx, must be installed
into the miniroot.
For network-based deployments that do not boot from the network, such as those that are
initiated by Rapid Deployment Pack, or those that boot from a custom CD ISO, the
HPQnetstrategy package must be installed into the miniroot. For more information about the
HPQnetstrategy package, see "Deployment resource kit."
For more information about preparing a miniroot for use in deploying ProLiant server and blades, see
"Miniroot preparation."
On the "Software and Drivers" load page, the cpqary3 driver is listed as "HP Driver
http://www.hp.com
on the "Software and
Architecture of an installation 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents