Fireplace Installation - Desa (V)CB36P(E) Installation And Owner's Operation Manual

4" b-vent decorative vented gas fireplace
Table of Contents

Advertisement

FIREPLACE INSTALLATION

CHECK GAS TYPE
Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas
type, do not install fireplace. See dealer where
you purchased your fireplace for proper gas type
fireplace or tro purchase gas conversion kit (see
Accessories, page 34).
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
CAUTION: For propane/LP
units, never connect fireplace
directly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between the
fireplace and propane/LP supply.
Installation Items Needed
Before installing fireplace, make sure you have
the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connector
(if allowed by local codes)
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable alterna-
tive to test gauge connection. Purchase the CSA
design-certified equipment shutoff valve from
your retailer.
For propane/LP connection only, the installer must
supply an external regulator. The external regula-
tor will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11" and
14" of water. If you do not reduce incoming gas
pressure, fireplace regulator damage could occur.
Install external regulator with the vent pointing
down as shown in Figure 22. Pointing the vent
down protects it from freezing rain or sleet.
14
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to fireplace.
If pipe is too small, undue loss
of volume will occur.
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up. NPT
tap must be upstream from fireplace (see Figure
23, page 15).
IMPORTANT: Install main gas valve (equipment
shutoff valve) in an accessible location. The main
gas valve is for turning on or shutting off the gas
to the appliance.
Check your building codes for any special re-
quirements for locating equipment shutoff valve
to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged fireplace valves.
sealant that is resistant to liquid
petroleum (LP) gas.
Propane/LP
Supply Tank
Figure 22 - External Regulator with Vent
Pointing Down (Propane/LP Only)
www.desatech.com
CAUTION: Use only new,
WARNING: Use pipe joint
External
Regulator
Vent
Pointing
Down
117437-01B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vcb36neCb36pCb36n

Table of Contents

Save Article as PDF