OPERATING FIREPLACE

MANUAL IGNITION SySTEM
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the knob
will not push in or turn by hand, don't try to
repair it, call a qualified service technician.
Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Open lower louver panel.
3. Turn off all electric power to the fireplace.
4. Push in gas control knob slightly and turn
clockwise
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information above. If you don't smell
gas go to the next step.
117437-01B
to OFF (see Figure 33).
www.desatech.com
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT.
8. Push in gas control knob all the way and
hold. Immediately light the pilot by re-
peatedly pressing the piezo ignitor until a
flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release
gas control knob and it will pop up. Pilot
should remain lit. If it goes out, repeat steps
5 through 8.
• If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If the pilot will not stay lit after several
tries, turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to fireplace.
10. Turn gas control knob counterclockwise
to ON.
11. Close lower louver panel.
Regulator Cap
Gas Control Knob
Figure 33 - Control Valve Millivolt
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set the wall switch to "OFF" position or
the HRC selector switch (when equipped)
to prevent draining the battery.
3. Turn off all electric power to the appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot
lit by doing one of the following:
1. Turn gas control knob clockwise
the PILOT position.
2. Set the wall switch to the OFF position or
the HRC selector switch (when equipped)
to prevent draining the battery.
Piezo Ignitor
to OFF.
to