Single Camera Connection

Note
Do not remove the 120 Ohm termination
resistor provided with the camera.

Multiple Camera Connections

For installations of more than one HCU484 camera in a
daisychain configuration, keep the 120 Ohm termination
resistor (provided with the camera) only in the last camera in
the series (see
daisychain, remove the 120 Ohm termination resistor.
Note
Up to 254 cameras can be daisychained.
Figure 6
HJZTP
Keyboard
Remove the 120 Ohm termination resistor
from all cameras except the last one.

Mounting the Camera

Mounting points are provided on the top and bottom of the
camera and are used to mount the camera on a bracket or
tripod. They are designed to accept standard sized mounting
bolts. The mounting bracket must be capable of supporting
the weight of the camera and its lens.
Caution
Some installation codes dictate that the
mounting bracket must be capable of
supporting up to four times the combined
weight of the camera and lens.

Making Final Adjustments

Adjust the focus in your field of view; that is, until you see a
clear image. If necessary, adjust the brightness using the OSD
menu controls (see
exposure on the monitor screen.
Rev 1.01
Figure
6). For all other cameras in the
Multiple Camera System
>BRIGHTNESS
1 - 254 cameras
on page 12). Confirm the
5
Last camera in
daisychain must have
the 120 Ohm termination
resistor installed.