Warnings Installation and servicing should be performed only by qualified and experienced personnel to conform to all local codes and to maintain your warranty. WARNING! 12 VDC/24 VAC models require the use of CSA Certified/UL Listed Class 2 power adapters to ensure compliance with electrical safety standards.
FCC Compliance Statement Information to the User: This equipment has been tested and found to comply with the limits for a Class A digital device. Pursuant to Part 15 of the FCC Rules, these limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Important Safety Information • Read and keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with dry cloth. • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Introduction The Honeywell HCD95534 Color IR camera is designed for exceptional value and performance and is ideally suited for use in day-to-day surveillance applications. The off-the-shelf feature set is designed for high picture quality in standard applications and the HCD95534 requires little to no adjustment after installation.
Note installation. Installation The HCD95534 camera is designed for installation on a wall or ceiling. The HCD95534 is weather sealed for indoor or outdoor locations. Attaching the Camera Position the camera to the desired mounting location on a wall or ceiling.
To ensure a waterproof installation, the notch in the camera base Note that the power and video connections exit through should be facing down. If the power and video connections exit the top of the base (wall mounted only), water may pool in the camera base. To minimize moisture entering the base, apply appropriate sealant around the notches and any other gaps between the camera base and the mounting surface.
Camera Settings Camera Functions Figure 3 Camera Controller VIDEO-TEST 1 STEP LUX LEVEL 2 STEP LEFT RIGHT 3 STEP DOWN SETUP (MENU) PUSH DOWN 4 STEP LED-LEVEL Legend # Description Video-test monitor output connector LUX-level adjustment DIP switches. Only one switch should be on at a time.
Legend # Description Press this control To do this … UP, DOWN Select a new item LEFT, RIGHT Select a menu item SETUP (MENU) Access a submenu Connecting the Camera Connect the BNC video output connector to the video-in connector on your monitor or video recorder.
Programming Setup Menu The HCD95534 menu system consists of one main Setup menu (see Figure 5) for easy camera programming. Press down on the SETUP (MENU) control (see Figure 3) to display the Setup menu. Figure 5 Setup Menu <<SETUP MENU>>...
Page 13
Menu Item Option Description SHUTTER Adjusts shutter settings. FLK = Flickerless mode reduces on-screen MANUAL flickering. This is the only option available when the camera lens is set to DC mode (recommended). ESC = Electronic Shutter Control adjusts brightness level on screen. MANUAL = Allows you to adjust the shutter speed from 1/60-1/120,000 of a second (NTSC), or 1/50-1/120,000 (PAL).
Menu Item Option Description Automatically provides a clear image under AUTO low-light conditions. You can control the (Digital Slow maximum low-light magnification from 2x to Shutter) 128x (increasing magnification may cause noise/distortion). DSS is deactivated when SHUTTER is set to FLK mode. SPECIAL Opens the SPECIAL menu (see next section).
SPECIAL Menu Functions Menu Item Option Description CAMERA Sets a name to be displayed on the monitor. Adding a Camera Title Display. COLOR AUTO Sets the camera to either automatic color/ black and white or full-time color mode. SYNC Synchronizes the vertical interval sync pulse of your camera with other equipment to reduce the effect of picture roll on the monitor.
Adding a Camera Title Display To add a camera title: On the Special menu, select CAMERA ID and then press SETUP MENU). Figure 7 Adding Camera Title <<CAMERA ID>> A B C D E F G H I J K L M N O P R Q S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z...
Configuring Sync Control/Line-lock Use this screen to synchronize the vertical interval sync pulse of your camera with other equipment to reduce the effect of picture roll on the monitor. Line-lock mode is only available when using 24 VAC power. Note Figure 8 Sync Control Setup <<SYNC.
Setting Up Motion Detection Use this screen to set up to four areas of the screen to detect moving objects. The screen displays along with the number of MOTION DETECTED movements counted. Figure 9 Motion Detection Setup <<MOTION DETECTION>> AREA SEL AREA 1 AREA STATE |..|....| 10...
Configuring Privacy Zones Use this screen to set up to four areas of the screen for privacy mode; that is, the camera does not record video in these areas. Figure 10 Privacy Mode Setup <<PRIVACY>> AREA SEL AREA 1 AREA STATE AREA TONE |....|...| 80 |..|....| 10...
Warranty and Service Subject to the terms and conditions listed on the Product warranty, during the warranty period Honeywell will repair or replace, at its sole option, free of charge, any defective product returned prepaid. In the event you have a problem with any Honeywell product, please call Customer Service at 1.800.796.CCTV (North America only) for assistance or...
Page 21
HCD95534 (NTSC) HCD95534X (PAL) Lens Type: 5-50 mm Vari-focal Auto Iris, IR corrected, F1.6 Horizontal Field of 51.3°–5.5° View: White Balance: ATW/AWC/Manual BLC: Off/On, selectable Gamma: 0.45 Line Lock Phase Adjustable Line lock vertical phase Adjustment: IR LEDs: 850 nm, 26 LEDs IR Illumination 125 ft (40 m)–150 ft (47 m), depending on scene...
Mounting Template Figure 11 Mounting Template Scale 1:1 Mounting screw holes (8/32 inch diameter) See “Attaching the Camera” on page 8 for information on using the mounting template. The camera enclosure should be mounted on a flat, smooth surface. Note Document 800-01802 Rev B 02/09...