Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
auer Manuals
Heat Pump
HRC70 25
Installation and operating instructions manual
auer HRC70 25 Installation And Operating Instructions Manual
High-temperature, modulating heat pump and pilot energy effi cient
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
page
of
84
Go
/
84
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Please Read Immediately
Important Information
Safety Instructions and Advice
Delivery Terms and Conditions
Storage and Transport
General Information
Transporting with a Forklift Truck
Transporting Manually
Introduction
Standard Confi Guration
Operating
Heat Pump Operation
Pilot Operation
Accessories (Included)
Accessories Available to Order
Installation
Installing the HRC
Installation Site
1- Heat Pump Installation Site
Condensates Drainage
Heater Cable for External Condensate Drainage
Protection Grid for the Fi Nned Heat Exchanger
Installing the Pilot
Installation Site
Fitting the Pilot to the Wall
Fitting and Placement
Plumbing Connections
Hydraulic Connections for the Installation
Hydraulic Connection : Heat Pump Circuit
Heat Pump and Pilot Relief Valve
Desludging
Heat Pump Water Inlet Fi Lter (Supplied)
Heating Circuit
Heating Circuit Fl Ow Rate
Backfl Ow Prevention Device
Degassing the Heating Circuit
Insulating the Piping
Expansion Vessel
Frost Protection and Water Treatment
Installation Advice for Diff Erent Types of Transmitters and Diff Erent Uses
For Radiator / Fan Coil Unit Circuits
For Underfl Oor Heating Circuits
For Domestic Hot Water
For Swimming Pools
Electrical Control Connections
Connecting the Heat Pump Control
2-Core Sheathed Cable
Connecting the Pilot
Temperature Controls
Installation Precautions
Room Thermostat
Outdoor Temperature Sensor
Connecting to Power Supply
Recommendations for Connecting the System to the Power Supply
Connecting the Pilot to the Power Supply
Pilot: 230V Single Phase Connection
Pilot: 400V Three Phase Connection
Connecting the HRC
Heat Pump to the Power Supply
Hrc
Hrc
Electrical Protection for the Compressors
Appliance Configuration
Control Box
Display Screen: Symbols and What They Mean
Commonly Displayed Symbols
Unlocking
Language
Installer Menu
Selecting the Right Back-Up for the Installation
Configuration of the HRC
Heat Pump and Circuits
Confi Guring Circuit 1
Circuit 1 Temperature Control
Confi Guring Circuit 2
Circuit 2 Temperature Control
Setting Operating Parametres
Setting the Heating Curve
Maintaining the Target Temperature (Comfort Mode)
Target Temperature in 'Eco' Mode
Target Temperature in Frost Protection Mode
Resetting Installer Parametres 205 to 230
Selecting the HRC
Forced Command of the System
Use
Setting the Date and Time
Displaying the Control Values
User Menu
Setting Target Temperatures
Setting the Ambience Target Temperature
Setting the Eco Target Temperature
Setting the Anti Freez Target Temperature
Setting the Domestic Hot Water Temperature
Setting the Swim. Pool Temperature
Setting a Vacation Period
Temporary Override of the Programmed Heating Mode
Boost Function
Selecting Summer / Winter Mode
Selecting the Language
Beep Alert
Accessing the INST. MENU
Maintenance and Repairs
General Information
Hydraulic Circuit Maintenance
Water Circuit Condensate Drainage
HRC Pilot
Heating Circuit Maintenance
Heat Pump Maintenance
Electrical Components Maintenance
Checking Operating Temperatures
Accessing Control Readings and Internal / External Controls
Accessing Calculated Data
Accessing the Meters
Errors Which Are Not Signalled by Error Message or Alert
Compressor Start-Up Faults
Alerts and Errors Which Are Signalled by the Appliance
Error Messages
Errors and Solutions
Operating in Case of Error
Sensor Data Curve Charts
Water Inlet and Outlet HRC
Sensors Fi Tted to Compressors 1 and 2
Swimming Pool Sensor - DHW Sensor
Outdoor Sensor
Notes / Maintenance
Decommissioning and Disposal
Parts
HRC 70 Heat Pump
Electrical Boxes
HRC Pilot
Warranty
Warranty Limits
General Information
Cases (Non Limited) for Exclusion from Warranty
Heating Circuit Water
Handling
Installation Site
Electrical Connections
Hydraulic Connections
Accessories
Maintenance
Appendices
A1 - Dimensions
A1.1 -HRC 70 Heat Pump
A1.2 - HRC Pilot
A2 - Technical Data
A2.1 -HRC 70 Heat Pump
A2.2 - HRC 70 Pilot
A3 - Frost Protection
A4 - Sizing the Expansion Vessel
A5 - Programming Heating Modes
A5.1 - Creating a New Programme
A5.2 - Copying Existing Programmes
A5.3 - Changing a Programme
A5.4 - View Programme
A6 - Heating Circuit Water Treatment
A6.1 - Preparing the Hydraulic Circuit (Rinsing)
A6.2 - Water for Fi Lling
A6.3 - Heating Circuit Treatment
A6.4 - Frost Protection
A7 - Performance Tables
A7.1 - HRC Heat Pump, 17Kw
A7.2 - HRC 70 Heat Pump, 20Kw
A7.3 - HRC 70 Heat Pump, 25Kw
RADIATOR CIRCUIT- -Swimming Pool Possible
UNDERFLOOR HEATING CIRCUIT- - Pool Possible
RADIATOR CIRCUITS- -Pool Possible
UNDERFLOOR CIRCUITS - -Pool Possible
RADIATOR CIRCUIT/ + DHW- -Pool Possible
Radiator Circuit + Pool
Pool Circuit + Dhw
DIRECT CIRCUIT and 1 MIXED CIRCUIT with Optional
Nd Circuit
At Lower Temperature (Ref.751014) -Pool Possible
DIRECT CIRCUITS and
Nd Circuit at a Lower Temperature (Ref.751014) and Optional
Possible
HRC Heat Pump - 17Kw Single Phase
Heat Pump and HRC 70 Pilot De-Icing Sensor
HRC Heat Pump- 17Kw Three Phase
HRC Heat Pump- 20Kw Three Phase
HRC Heat Pump- 25Kw Three Phase
Hrc
HRC 70 Pilot Internal Wiring Diagram
A8 - Electricity Provider Information Form
Advertisement
Quick Links
Download this manual
HRC
High-temperature, modulating
70
HRC
Heat Pump and Pilot
Energy Effi cient
Installation and operating instructions
Manual ref: 1871442
Edition n°: 15.356
The information contained in this document is non-contractual. Auer reserves the right to modify all technical data and equipment of our products without prior notice.
70
HRC
Pilot
70
High-temperature
HRC
70
modulating
heat pump
70
HRC
17 single phase
Ref.151201
HRC
70
17 three phase
Ref.151211
70
HRC
20 three phase
Ref.151271
HRC
70
25 three phase
Ref. 151221
Made
in France
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the HRC70 25 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for auer HRC70 25
Heat Pump auer HRC70 35/2 t Installation And User Manual
High temperature, modulating 35kw (24 pages)
Heat Pump auer HRC70 17 Installation And Operating Instructions Manual
High-temperature, modulating heat pump and pilot energy effi cient (84 pages)
Heat Pump auer HRC70 20 Installation And Operating Instructions Manual
High-temperature, modulating heat pump and pilot energy effi cient (84 pages)
Heat Pump auer HRC70 Installation And Operating Instructions Manual
High temperature heat pump and energy efficient (76 pages)
Heat Pump auer HRC70 Installation And User Manual
High temperature heat pumps from 17 to 25 kw (44 pages)
Heat Pump auer HRC 70 PILOT-PREMIUM Installation And User Manual
For high temperature heat pump from 7 kw to 25 kw three-phase (60 pages)
Heat Pump auer HTi70 6 Installation And User Manual
High temperature, ultra modulating heat pump (28 pages)
Heat Pump auer HTi70 6 mono Installation And User Manual
High temperature, ultra modulating heat pump (32 pages)
Heat Pump auer HTi70 11 Installation And User Manual
High temperature, ultra modulating heat pump (32 pages)
Heat Pump auer HTi70 14 Installation And User Manual
High temperature, ultra modulating heat pump (32 pages)
Heat Pump auer DS170 d Installation Manual
Pilot for hrc70 & hti70 heat pumps (40 pages)
Heat Pump auer PRIMO pilot Technical Installation Manual
Pilot for hrc70 & hti70 heat pumps (36 pages)
Heat Pump auer HRC 70 32 three-phase /3 Installation And User Manual
High temperature, modulating heat pump (28 pages)
Heat Pump auer Premium+ Installation Manual
(44 pages)
Heat Pump auer Edel 100 AIR Installation Manual
Domestic hot water heat pump 100 and 150 litres wall mounted (36 pages)
Summarization of Contents
Important Safety and Initial Information
Important Information
Details crucial notes for warranty validity and manual usage. Essential reading before appliance use.
Safety Instructions and Advice
Provides critical safety warnings and recommendations for installation and operation of the heat pump.
Delivery Terms and Conditions
Outlines that material is transported at the recipient's risk and the need to check for damage.
Storage and Transport Guidelines
Covers general, forklift, and manual transport requirements and precautions for the appliances.
Introduction to the HRC70 System
Standard Configuration Overview
Describes the typical setup comprising an outdoor Heat Pump unit and an indoor Pilot unit.
System Operating Principles
Explains how the Heat Pump and Pilot units function and interact for heating purposes.
Included Accessories
Lists components that are supplied with the Pilot but require assembly.
Available Accessories
Details optional components that can be ordered to enhance system functionality.
Installation Procedures and Guidelines
Installing the HRC70 Heat Pump Unit
Covers the physical installation of the outdoor heat pump unit.
Heat Pump Installation Site Requirements
Specifies the correct outdoor location, minimum distances, and environmental considerations.
Condensate Drainage Setup
Details methods for draining condensate water, including options for external heater cables.
Installing the HRC70 Pilot Unit
Covers the installation of the indoor pilot unit, including site selection and mounting.
Plumbing and Hydraulic Connections
Guides on making all necessary water and hydraulic connections for the system.
Heating Circuit Installation Advice
Details for heating circuits, flow rates, backflow prevention, degassing, insulation, and frost protection.
Installation Advice for Different Uses
Specific installation guidance for radiator, underfloor, domestic hot water, and pool systems.
Electrical Control Connections
Covers connecting the heat pump control, pilot, and temperature sensors.
Connecting to Power Supply
Provides recommendations and diagrams for connecting the heat pump and pilot to the electrical supply.
Electrical Protection for Compressors
Details on electrical protection devices to prevent compressor damage from voltage or current issues.
Appliance Configuration and Settings
Control Box Interface
Explains the symbols, display, and basic operations of the control box interface.
Installer Menu Navigation
Guides on accessing and navigating the installer menu for system configuration.
Selecting Installation Back-up
Details how to choose the appropriate back-up system (HP only, HP+Boiler, HP+Electric).
Configuring Heat Pump and Circuits
Steps for selecting the heat pump model and configuring heating circuits and their temperature controls.
Setting Operating Parameters
Instructions for adjusting heating curves, target temperatures for Comfort, Eco, and Frost Protection modes.
Forced Command System Operations
Allows manual engagement of components for diagnosis or temporary control.
Using the HRC70 System
Setting Date and Time
Guides on setting the system's date and time for automatic heating mode adaptation.
Displaying Control Values
Explains how to access and view system data like temperatures, pressure, and sensor readings.
User Menu Operations
Covers accessing settings for heating modes, operating the appliance, and viewing temperatures.
Setting Target Temperatures
Instructions for setting target temperatures for Ambient, Eco, Anti-Freeze, DHW, and Pool modes.
Vacation Mode Setting
Enables setting a vacation period to put the appliance on standby while maintaining frost protection.
Temporary Override of Heating Mode
Allows manual adjustment of the heating mode for specific periods, overriding the programmed schedule.
BOOST Functionality
Temporarily forces the heat pump and back-up to speed up temperature rise.
Summer/Winter Mode Selection
Allows manual switching between summer and winter modes or automatic switching based on temperature.
Accessing Installer Menu from User Menu
Procedure to access the installer menu from the user menu for advanced settings.
Maintenance and Repair Procedures
General Maintenance Information
Provides general advice on checking water circuits, condensates, and environmental protection.
Hydraulic Circuit Maintenance
Covers cleaning filters, checking for leaks, and maintaining the water circuit.
Heat Pump Maintenance
Specific maintenance tasks for the heat pump unit, including cleaning fins.
Electrical Components Maintenance
Guidance on safely checking and maintaining electrical connections and components.
Checking Operating Temperatures
Explains how to access and interpret sensor readings for operating temperatures.
Error Handling and Troubleshooting
Details errors not signalled by messages and lists compressor start-up faults and alerts.
Detailed Error Messages and Solutions
Provides a comprehensive list of error codes, their nature, and solutions for rectification.
Operating in Case of Error
Describes system behavior and error removal procedures when specific faults occur.
Sensor Data Curve Charts
Presents charts showing resistance values for various sensors at different temperatures.
Decommissioning and Disposal
Outlines procedures for safely decommissioning and disposing of the appliance.
System Components and Parts
HRC70 Heat Pump Parts List
Lists all individual components of the HRC70 Heat Pump with their references.
Electrical Boxes Identification
Identifies the components within the electrical boxes for different heat pump models.
HRC70 Pilot Parts Identification
Lists and identifies the various components and connections on the HRC70 Pilot unit.
Warranty Information and Limits
General Warranty Terms
Details the warranty period, coverage, and conditions for appliance guarantee.
Exclusions from Warranty Coverage
Lists specific cases and conditions that void the appliance warranty.
Appendices and Technical Data
Appliance Dimensions
Provides detailed physical dimensions for the HRC70 Heat Pump and Pilot units.
Technical Data Specifications
Lists key technical specifications for both the Heat Pump and Pilot units.
Frost Protection Guidelines
Explains measures to protect the system from frost, especially when a back-up source is unavailable.
Expansion Vessel Sizing
Provides guidance on calculating and sizing the expansion vessel based on installation height and volume.
Programming Heating Modes
Details on programming daily heating schedules, copying programs, and viewing current settings.
Heating Circuit Water Treatment
Covers preparing the circuit, water quality, treatment products, and frost protection with glycol.
Performance Data Tables
Presents performance tables for different models under various operating conditions.
Electricity Provider Information Form
A form to provide to electricity providers for preliminary studies on heat pump installation.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the HRC70 25 and is the answer not in the manual?
Questions and answers