Questions and answers

Summarization of Contents

General Information and Safety Instructions
Intended Use
Specifies the intended applications and network for the room control unit.
Improper Use
Details prohibited applications and conditions for the room control units.
Limitation of Liability
Outlines the manufacturer's liability for damages due to misuse or improper installation.
Support
Provides contact information for technical assistance and product support.
Product Features Overview
Device Versions
Presents the different physical models of the NOVOS and thanos EVO room control units.
Assembly and Commissioning Guide
Device Connection
Covers the physical connection of devices, including wiring and power supply requirements.
RS485 Wiring Specifications
Details the specifications and limitations for RS485 bus wiring, including cable length and termination.
AC Power Supply Connection
Explains the correct procedure for connecting devices to an AC power supply.
Electrical Connection Details
Illustrates the electrical connections for power supply and RS485 bus interface.
RS485 BUS Configuration
Describes how to assign unique addresses and configure the RS485 bus parameters for devices.
Device Configuration Process
Introduces the methods and tools available for device configuration, such as software applications.
Modbus Register Data Structure
Explains the organization of configuration and communication data within Modbus registers.
Display and User Operation
Display and Operating Elements
Details the physical interface elements and user interaction methods for different device models.
Home Screen Navigation
Describes the default display screen, its customizable elements, and status indicators.
Status Bar Information
Explains the various icons and information displayed in the header of the main screen.
Main Menu Navigation
Outlines the navigation structure and access to different functional menus on the device.
Climate Menu Operations
Details the controls for temperature adjustment, ECO mode, and room occupancy.
Scene Menu Configuration
Explains how to configure and activate predefined scenes for room ambiance and control.
Light Menu Control
Covers the management and control of lighting groups, including dimming and icon selection.
Color Picker Functions
Describes the interface for adjusting RGB(W) colors and color temperature for lighting.
RS485 Modbus Register Specification
Data Block "Favourites"
Defines how to use favorite registers for custom project-specific data structuring and faster access.
Data Block "Room Climate"
Specifies registers for room occupancy, ECO mode, setpoints, and fan stage control.
Data Block "Lighting"
Details registers for controlling lighting states, color values, and dimming settings.
Data Block "Shading"
Provides register specifications for controlling blinds, shutters, and curtains, including slat angle.
Data Block "Status Display and Special Functions"
Covers registers for display status, LED control, and device restart functions.
Data Block "Sensors"
Lists registers for reading sensor values like temperature, humidity, CO2, and VOC.
Configuration Data Blocks
Configuration Data Block "Device"
Contains parameters related to device identification, production date, and firmware versions.
Configuration Data Block "General"
Includes general settings such as measurement unit, language, date/time formats, and maintenance countdowns.
Configuration Data Block "Display"
Specifies parameters for controlling display brightness, standby behavior, screensavers, and icons.
Configuration Data Block "Climate"
Details settings for climate control, including setpoint definition, ECO button, and room occupancy display.
Configuration Data Block "Lighting"
Covers configuration settings for lighting menus, number of circuits, and graphical representation.
Configuration Data Block "Shading"
Provides configuration options for shading menus, number of circuits, and graphical representation.
Configuration Data Block "Scenes"
Details settings for scene menus, number of scenes, and icon selection for each scene.
Configuration Data Block "Sensors"
Specifies configuration parameters for displaying and setting thresholds for various sensors.
Configuration Data Block "Favourites"
Defines configuration parameters for setting up favorite buttons on the home screen.
Coil Data Blocks
Coil Data Block "Lighting"
Lists coils for controlling the ON/OFF state of lighting circuits and their status.
Coil Data Block "Scenes"
Details coils for activating or deactivating specific scenes and their status.
Coil Data Block "Display" (Icons)
Specifies coils for controlling the visibility of various status icons on the display.
AUTO Mode Coils for Lighting 1-8
Defines coils for enabling/disabling AUTO mode for individual lighting circuits.
AUTO Mode Coils for Shading 1-8
Details coils for enabling/disabling AUTO mode for individual shading circuits.
Scheduler Time Channels
Explains the configuration of time channels for automated, time-controlled actions.
Modbus Protocol
Supported Control Commands
Lists the MODBUS function codes supported by the device for communication.
Data Transmission Details
Describes the Master/Slave protocol and the structure of data frames used in Modbus communication.
Transmission Mode RTU
Explains the RTU transmission mode, telegram structure, and CRC checksum calculation.