Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
BEKA Manuals
Measuring Instruments
BA328C
Manual
BEKA BA328C Manual
Intrinsically safe loop-powered 4 1/2 digit panel mounting indicators
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
page
of
32
Go
/
32
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Description
2 Operation
Controls
3 Intrinsic Safety Certification
ATEX Certificate
4/20Ma Input
Zones, Gas Groups & T Rating
Certification Label Information
4 System Design for Hazardous Areas
Transmitter Loops
Remote Indication
5 Installation
Location
Installation Procedure
Emc
6 Programming and Calibration
Summary of Programmable Functions
Root Extractor
Calibration Using an External
Current Source
Calibration Using Internal References
Conditioning Sub-Menu
AC Rejection
Calibration of Internal References
Function of the P Push-Button
Security Code
Over and Under-Range
7 Calibration Example
Using an External Calibrator
Using the Internal Calibrator
8 Maintenance
Fault Finding During Commissioning
Fault Finding after Commissioning
Servicing
Routine Maintenance
Guarantee
Customer Comments
9 Accessories
Scale Card
Tag Strip
Alarms
Solid State Output
Intrinsic Safety
Programming and Adjustment
Alarm Enable
Alarm Silence Time
Access Setpoint
Adjusting Alarm Setpoints from Display Mode
Lineariser
Calibration Using an External Source
Calibration Using Internal
Tare Function
Display Backlight
Separately Powered Backlight
Loop Powered Backlight
Appendix 1 FM & Cfm Approval for Installation in USA and Canada
Appendix 2 Iecex Certification
Advertisement
Quick Links
1
Controls
2
Programming and Calibration
3
Calibration Using an External
4
Calibration Using Internal References
Download this manual
BA327C & BA328C
intrinsically safe
loop-powered
4½ digit panel
mounting indicators
issue 11
Issue: 11
rd
3
November 2009
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the BA328C and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for BEKA BA328C
Measuring Instruments BEKA BA307E Instruction Manual
(2 pages)
Measuring Instruments BEKA BA304NE Manual
Type n loop-powered field mounting indicators (28 pages)
Measuring Instruments BEKA BA324ND Manual
Type nl certified loop-powered 4.5 digit field mounting indicator (27 pages)
Measuring Instruments BEKA BA304NE Quick Start Manual
(2 pages)
Measuring Instruments BEKA BA327E-SS Manual
Intrinsically safe loop-powered rugged panel mounting indicators (42 pages)
Measuring Instruments BEKA BA327NE Manual
Ex na & ex tc loop-powered panel mounting indicators (31 pages)
Measuring Instruments BEKA BA324G Manual
Intrinsically safe loop-powered field mounting indicators (39 pages)
Measuring Instruments BEKA BA304G Manual
Intrinsically safe loop-powered field mounting indicators (39 pages)
Measuring Instruments BEKA BA304NG Manual
Ex na & ex tc loop-powered field mounting indicators (29 pages)
Measuring Instruments BEKA BA324D Manual
Intrinsically safe loop-powered 4 1/2 digit field mounting indicator (30 pages)
Measuring Instruments BEKA BA304SG Quick Start Manual
(2 pages)
Measuring Instruments BEKA BA304SG Manual
Increased safety ex eb and dust ignition protection by enclosure ex tb loop-powered field mounting indicators (21 pages)
Measuring Instruments BEKA BA327C Manual
Intrinsically safe loop-powered 4 1/2 digit panel mounting indicators (32 pages)
Measuring Instruments BEKA BA304E Manual
Intrinsically safe loop-powered field mounting indicators (40 pages)
Measuring Instruments BEKA BA327SE Application Manual
(28 pages)
Measuring Instruments BEKA BA329 Series Manual
Intrinsically safe 8 input 4/20ma panel mounting indicators (21 pages)
Summarization of Contents
Description of BA327C & BA328C Indicators
Operation of BA327C & BA328C Indicators
Controls Overview
Details the functions of the four front panel push-buttons in display mode.
Intrinsic Safety Certification
ATEX Certificate Details
Outlines the EC-Type Examination Certificate details and compliance with ATEX Directive.
4/20mA Input Parameters
Specifies output parameters for intrinsic safety and equivalent capacitance/inductance.
Hazardous Zone Classification
Details the certification EEx ia IIC T5 for installation in hazardous zones.
Certification Label Information
Describes information found on the instrument's certification label.
System Design for Hazardous Areas
Transmitter Loop Connections
Explains how indicators connect in series with intrinsically safe 4/20mA current loops.
Remote Indication Setup
Describes using intrinsically safe interfaces for remote indication in hazardous areas.
Installation Guide
Location and Mounting
Discusses instrument housing, IP65 protection, and panel mounting considerations.
Installation Procedure Steps
Step-by-step guide for inserting the indicator and securing it with mounting clips.
EMC Compliance
Details compliance with EMC Directive and recommended wiring practices for immunity.
Programming and Calibration
Programmable Functions Summary
Overview of main programmable functions like root extraction, resolution, and calibration.
Root Extractor Function
Explains how to activate the square root extractor for linearizing differential flowmeters.
Display Resolution Settings
Defines how to select the display resolution for the least significant digit.
Decimal Point Positioning
Describes how to position or remove the dummy decimal point on the display.
External Calibration Procedure
Details calibrating zero and span using an external current source.
Internal Calibration Procedure
Explains how to adjust zero and span using internal references without an external source.
Conditioning Sub-menu
Provides access to sub-menu for calibrating internal references and selecting mains frequency rejection.
P Push-button Function Definition
Defines the P push-button function to display input current in mA or percentage.
Security Code Management
Describes setting a four-digit code to protect access to programmable functions.
Over and Under-Range Indicators
Explains indicator behavior for over/under-range conditions and input current thresholds.
Calibration Examples
External Calibrator Usage
Step-by-step guide for calibrating the indicator using an external current source.
Internal Calibrator Usage
Step-by-step guide for calibrating the indicator using its internal references.
Maintenance Procedures
Fault Finding During Commissioning
Procedure for diagnosing and resolving issues during initial setup.
Fault Finding After Commissioning
Procedure for diagnosing and resolving issues after the instrument is operational.
Servicing and Repair
Information on replacing or repairing instruments and recommendations for returns.
Routine Maintenance Schedule
Recommendations for regular checks of mechanical condition and electrical calibration.
Guarantee Information
Guidance on returning instruments that fail within the guarantee period.
Customer Feedback
Encourages customer feedback for product improvement.
Accessories for BA327C & BA328C
Scale Card Installation
Describes how to mark and install scale cards for displaying measurement units.
Tag Strip Identification
Mentions thermally printed tag numbers on the rear panel for identification.
Alarm System Overview
Details the capabilities and programming of the two solid-state alarm outputs.
Solid State Alarm Output
Explains the galvanically isolated single pole solid state switch output for alarms.
Alarm Intrinsic Safety
Covers intrinsic safety certification for alarm outputs as simple apparatus.
Alarm Programming and Adjustment
Describes how alarm functions extend the main program menu and lists alarm parameters.
Lineariser Functionality
Explains the sixteen-point lineariser for compensating non-linear variables.
Tare Functionality
Describes the software accessory for zeroing the display, often used with weighing systems.
Display Backlight Options
Discusses the two types of backlights: loop powered and separately powered.
Separately Powered Backlight
Details the separately powered backlight, its certification, and power requirements.
Loop Powered Backlight
Explains the loop-powered backlight, its connection, and cost reduction benefits.
Appendix 1: FM & cFM Approval for USA and Canada
Factory Mutual Approval Overview
Covers Factory Mutual approval for intrinsic safety and nonincendive use in hazardous locations.
4/20mA Input in Intrinsically Safe Circuits
Details entity parameters for 4/20mA input in intrinsically safe circuits.
4/20mA Input in Nonincendive Circuits
Describes FM approval as nonincendive for Class I, Division 2 locations.
Accessory Approval
Mentions approval for accessories like alarms and backlight with external connections.
Alarm System Approval
Discusses FM approval for alarm cards with two independent alarms.
Display Backlight Approval
Covers approval for both separately powered and loop powered backlights.
Appendix 2: IECEx Certification
IECEx Certification Scheme
Provides information on the IECEx global certification scheme for explosion protected products.
IECEx Certificate of Conformity
Specifies the IECEx Certificate of Conformity number and marking for the indicators.
IECEx Installation Requirements
Confirms identical safety parameters and installation requirements for IECEx and ATEX approvals.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the BA328C and is the answer not in the manual?
Questions and answers