• Remove all other loose objects from the area that could be drawn into the machine. • Follow the recommended Kodak cleaning procedures. Do not use air, liquid or gas spray cleaners. These cleaners only displace the dust, dirt or debris to another location within the Check Scanner, which could cause the Check Scanner to malfunction.
UL 60950-1 CFR 47 Part 15 Subpart B FCC Class A Environmental • The Kodak i6000 Series Check Scanners are designed to meet worldwide environmental requirements. information • Guidelines are available for the disposal of consumable items that are replaced during maintenance or service; follow local regulations or contact Kodak locally for more information.
Acoustic emission Maschinenlärminformationsverordnung – 3, GSGV Der arbeitsplatzbezogene Emissionswert beträgt <70 db(A). [Machine Noise Information Ordinance — 3, GSGV The operator-position noise emission value is <70 dB(A).] EMC statements United States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules.
USB connection to your PC for viewing. The following models are available: • Kodak i6015 Check Scanner — automatically scans the front and/or back of a document one document at a time. • Kodak i6060 Check Scanner — automatically scans the front and/or back of documents at up to 65 documents per minute.
2 Getting Started What’s in the box Before you begin, open the box and check the contents: • Kodak i6000 Series Check Scanner or Kodak i6000 Series Check Scanner with Inkjet Printer • USB 2.0 cable • Power supply • Inkjet cartridge (if printer is included) •...
• Make sure that the power outlet is located within 1.52 metres (5 feet) of the scanner and is easily accessible. • Use only the power supply that was provided with the Kodak i6000 Series Check Scanners. Do not substitute another power supply model or another manufacturer’s power supply.
Installing the drivers Windows 2000 1. Logon to the PC with an account that has system administrative privileges. 2. Place the Installation CD in your CD-ROM drive. The installation utility will start up automatically. 3. Click Next to display the Destination Folder window. A-61557 December 2006...
Page 10
4. Click Next to select the type of setup. 5. Select the Typical installation and click Next . A-61557 December 2006...
Page 11
6. Click Install to begin the installation. When finished, the following window will be displayed: 7. Click Finish . The Kodak ScanTest Software icon will be placed on your desktop. 8. Remove the installation CD from the CD drive. 9. When finished with the installation, turn on the scanner.
Page 12
If the PC does not recognize the Kodak i6000 Series Check Scanner: 1. Go to Start>My Computer, right mouse click and select Properties. The Properties dialog box will be displayed. 2. Select the Hardware tab and click Device Manager to display the Device Manager window .
Page 13
The Update Device Driver Wizard window is displayed: 5. Click Next . 6. Select Search for a suitable driver for my device (recommended) and click Next . A-61557 December 2006...
Page 14
7. Select CD-ROM drives and click Next . 8. Click Finish . The Kodak ScanTest Software icon will be placed on your desktop. A-61557 December 2006...
Windows XP 1. Logon to the PC with an account that has system administrative privileges. 2. Place the Installation CD in your CD-ROM drive. The installation utility will start up automatically. 3. Click Next to display the Destination Folder window. A-61557 December 2006...
Page 16
4. Click Next to select the type of setup. 5. Select the Typical installation and click Next . A-61557 December 2006...
Page 17
6. Click Install to begin the installation. When finished, the following window will be displayed: 7. Click Finish . The Kodak ScanTest Software icon will be placed on your desktop. 8. Remove the installation CD from the CD drive. 9. When finished with the installation, turn on the scanner.
Page 18
If the PC does not recognize the Kodak i6000 Series Check Scanner: 1. Go to Start>My Computer, right mouse click and select Properties. The Properties dialog box will be displayed. 2. Select the Hardware tab and click Device Manager to display the Device Manager window .
Page 19
5. Click Next . 6. Select Install from a list or specific location (Advanced) and click Next . 7. Select Search removable media (floppy, CD-ROM...) and click Next . A-61557 December 2006...
Page 20
8. Click Finish . The Kodak ScanTest Software icon will be placed on your desktop. A-61557 December 2006...
Scanner components Front view Back Scanner top cover cover Indicator lights Exit Side cover stop wire Exit tray Automatic feeder Input tray Automatic feeder and input tray — depending on the document thickness and condition, holds up to 50 documents. Place documents in the input tray for scanning ( i6060 and i6090 Scanners only) .
Page 22
Inside view Inkjet printer Entry separation drive roller Entry separation drive roller — feeds checks into the scanner ( i6060 and i6090 Scanners only ). Main drive rollers (1 - 4) — these rollers along the scanner path, provide smooth document feeding of various sizes, thicknesses and textures of documents.
3 Using the Scanner Turning the scanner • Toggle the power switch on the back of the scanner to turn the scanner on or off. on and off After you turn on the scanner, wait for it to complete the self-test. When completed, the red LED will remain on and constant.
Scanning your 1. Place the documents into the input tray of the scanner until the left documents LED is lit. Be sure to slide the documents far enough forward so the scanner can detect the documents. NOTE: If checks do not sit flat in the paper path, the Paper Detect LED may not recognize their presence.
• Cleaning frequency can be reduced if you allow the ink on the check to completely dry before scanning. • Videos demonstrating proper cleaning techniques can be found on the PC, under Start>Programs>Kodak , if the installation CD that came in the Welcome Folio has been run. Daily cleaning 1.
Page 26
Steps 6 through 8 remove the residual dirt on the four drive rollers. 9. When finished, discard the cleaning card and shut down the Kodak ScanTest Software. A-61557 December 2006...
Weekly cleaning A weekly cleaning should be performed approximately every fourth procedure regular cleaning cycle. 1. Before starting this procedure, perform the daily cleaning procedure as outlined in the previous section. 2. Turn the scanner off. 3. Remove the scanner top cover. 4.
Page 28
6. Lift and remove the back cover. NOTE: If the back cover does not easily lift up, be sure that the exit stop wire is pulled out approximately 4 inches. 7. Loosen and remove the thumbscrew that holds the scan tower door in place.
Page 29
12. Launch the Kodak ScanTest Software. 13. Clean each drive roller by selecting Eject on the Kodak ScanTest Software window. Selecting Eject will turn the drive rollers for about 5 seconds. 14. Thoroughly clean all of the drive rollers (black and white) with the swab.
Replacing the ink If you are using the Inkjet Printer, periodically you will need to change cartridge the ink cartridge. The ink cartridge should be changed when the endorsement print is light and difficult to read. Replacement cartridge: Hewlett-Packard Inkjet Cartridge hp c6602a (CAT No.
Right LED on - red Scanner is powered-on. Right LED on - green Scanner is ready for operation and has detected the Kodak t6000 Client Software. Left LED on Scanner detects the presence of documents in the input tray. Flashing An error has been encountered.
If a document jam occurs, try one of the following methods to clear the document path: • If you are using the Kodak ScanTest Software, select the Eject button. • If the document does not clear the paper path, grasp the document with both hands and carefully wiggle it back and forth as you lift it out of the paper path.
Problem solving Use the chart below as a guide to check possible solutions to problems you may encounter when using the Kodak i6000 Series Check Scanners. Periodic and scheduled cleanings should be performed before determining if any further problem resolution is needed. Refer to Chapter 4, Maintenance for complete cleaning procedures.
Problem Possible Solution 553 No print head The check scanner may not be recognizing the ink cartridge for one of the following reasons. Refer to the procedures in “Replacing the ink cartridge” earlier in the chapter for proper installation procedures. •...
Appendix A Specifications Scanning device 2 x 850 cell, 108 mm Contact Image Sensor (CIS) Light source Tri-color LED Scanning method Concurrent, duplex (front and rear) Document size Height: 56 to 106 mm (2.12 to 4.17 in.) 99 to 228 mm (3.91 to 8.97 in. Length: Weight: 60 to 120 g/m (16 to 32 lbs.)
Page 36
MICR recognition Recognition algorithm for E13B, CMC7 or CMC0 standards performed by the API MICR data transmission Analog waveform through the USB port Temperature Operating: 60 - 90°F (15 - 32°C) Storage: 32 - 104°F (0 - 40°C) Humidity 35 to 85% non-condensing Scanner Dimensions Height: 6.8 in.
Page 37
MICR recognition Recognition algorithm for E13B, CMC7 or CMC0 standards performed by the API MICR data transmission Analog waveform through the USB port Temperature Operating: 60 - 90°F (15 - 32°C) Storage: 32 - 104°F (0 - 40°C) Humidity 35 to 85% non-condensing Scanner Dimensions Height: 6.8 in.
Need help?
Do you have a question about the I6060 - Check Scanner and is the answer not in the manual?
Questions and answers