BANDELIN Sonorex Super 510 User Instructions

BANDELIN Sonorex Super 510 User Instructions

Ultrasonic baths for aqueous fluids

Advertisement

User instructions
3 6
Ultrasonic baths for aqueous fl uids
Valid for:
RK 31, RK 31 H, RK 52, RK 52 H
RK 100, RK 100 H, RK 102 H, RK 103 H, RK 106
RK 156, RK 156 BH
RK 170 H
RK 255, RK 255 H
RK 510, RK 510 H, RK 512 H
RK 514, RK 514 H, RK 514 BH
RK 1028, RK 1028 H, RK 1028 C, RK 1028 CH
RK 1040, RK 1050, RK 1050 CH
1556g GB/2019-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sonorex Super 510 and is the answer not in the manual?

Questions and answers

Summary of Contents for BANDELIN Sonorex Super 510

  • Page 1 User instructions Ultrasonic baths for aqueous fl uids Valid for: RK 31, RK 31 H, RK 52, RK 52 H RK 100, RK 100 H, RK 102 H, RK 103 H, RK 106 RK 156, RK 156 BH RK 170 H RK 255, RK 255 H RK 510, RK 510 H, RK 512 H RK 514, RK 514 H, RK 514 BH...
  • Page 2 Copyright & limitation of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any difference in the translation is not binding and has no legal effect.
  • Page 3 Operating sequence Identifi es instructions that are to be followed in the described  instructions sequence. 1556g GB/2019-02 3 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 4: Table Of Contents

    Cleaning and maintenance of the ultrasonic bath ............21 Cleaning and care ......................21 Disinfection for medical applications ................21 Warehousing / storing ....................21 4 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 5 Required accessories ....................24 Preparations ......................... 24 Taking the unit out of service ..................25 Informative appendices Accessories Foil test Dosing table 1556g GB/2019-02 5 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 6: Product Description

    This produces an especially homogeneous and uniform ultrasound fi eld in the bath volume for constantly reproducible results. 6 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 7: Purpose

    In Germany: Empfehlung der Kommission für Krankenhaushygiene und Infektionsprävention (KRINKO) beim Robert Koch-Institut (RKI) und des Bundesinstitutes für Arzneimittel und Medizinprodukte (BfArM); Bundesgesundheitsblatt - 2012•55:1244-1310. Exception: see "Technical data" overview 1556g GB/2019-02 7 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 8: Technical Data

    300 × 240 × 150 G ½ 640 / 160 RK 510 H 300 × 240 × 150 G ½ 640 / 160 8 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 9: Electromagnetic Ambient Conditions (Emc)

    1556g GB/2019-02 9 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 10: Warnings And Safety Precautions

    • Ultrasound cleaning is especially suited for instruments made of stainless steel and hard plastics. Do not treat lenses, camera systems or light cables with ultrasound. 10 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 11: Preparation

    This test is to be saved for later comparison, see appendix for information. If applicable, hang accessories in the ultrasonic bath and place lid on top. 1556g GB/2019-02 11 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 12: Operation

    • An “engaging” of the time switch is barely felt if mains voltage is not present, e. g. if the mains plug is disconnected or the fuse is blown. The time switch only works if mains voltage is present. 12 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 13: 3.1.2 Heating

    (with and without a fl ashpoint), the bath temperature can increase to >120 °C due to the energy input of the ultrasound. This leads to irreparable damage to the ultrasonic bath. 1556g GB/2019-02 13 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 14: Use

    • When using preparations, the safety instructions included in the product leafl ets are to be fundamentally adhered to. • Replace used sonication fl uids, do not refresh by adding fl uids. 14 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 15 • Prepare the disinfectant with cold water, operate the ultrasonic bath without heating and avoid temperatures above 40 °C. MILLNER, R.: Wissenspeicher Ultraschalltechnik, Fachbuchverlag publishing house, Leipzig 1987 1556g GB/2019-02 15 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 16: General Use

     For an even warming of fl uids, stir the fl uids or switch on the ultrasound for a few minutes now and then, otherwise there will be a retardation of boiling - risk of scalding! 16 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 17 In the case of stubborn residue, conduct sonication for a longer time if necessary.  Place lid on top.  Using the turning knob, set the desired sonication time, see chapter 3.1.1. 1556g GB/2019-02 17 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 18  After emptying the oscillating tank, thoroughly rinse it. Rub dry with a soft cloth. For additional care instructions, see chapter 5. 18 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 19: Treatment Of Medical And Dental Instruments

    In Germany: Empfehlung der Kommission für Krankenhaushygiene und Infektionsprävention (KRINKO) beim Robert Koch-Institut (RKI) und des Bundesinstitutes für Arzneimittel und Medizinprodukte (BfArM); Bundesgesundheitsblatt - 2012•55:1244-1310. 1556g GB/2019-02 19 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 20: Further Information

    In every case, the statutory provisions and regulations of municipal wastewater plants must be adhered to. Information is provided by municipal wastewater plants as well as by environmental agencies. 20 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 21: Cleaning And Maintenance Of The Ultrasonic Bath

    During long periods of non-use, the ultrasonic bath is to be stored in a cool, dry location. The lid should be placed on top in order to protect the oscillating tank from outside contamination. 1556g GB/2019-02 21 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 22: Maintenance And Repair

     Emergence of light erosion on the bottom of the  Natural wear. tank? Ultrasonic bath OK. Any malfunctions are to be communicated in writing to the manufacturer. 22 / 36 1556g GB/2019-02 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 23: Repairs And Service

    The form can be downloaded from the Internet as a PDF fi le: www.bandelin.com / Download ... 1556g GB/2019-02 23 / 36 1 electronic GmbH & Co. KG • Heinrichstraße 3-4 • 12207 Berlin • Deutschland • info@bandelin.com...
  • Page 24: Accessories

    Exceptions to this rule are special baskets and basket holders (e.g. K 6 and SH 7) that have been designed by BANDELIN in such a manner that they are not located in the cavitation fi eld and do not damage the tank bottom.
  • Page 25: Taking The Unit Out Of Service

    Taking the unit out of service If the ultrasonic bath no longer works, it must be disposed of appropriately. BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifi ziert nach Heinrichstraße 3 – 4 info@bandelin.com ISO 9001 12207 Berlin  +49 30 768 80-0...
  • Page 26 Accessories Insert basket K ..., made of stainless steel, sieve cloth. Protects objects to be cleaned and prevents damages to the tank bottom. Optimum ultrasound transmission. Utensil holder GH ..., made of stainless steel, mesh size 12 x 12 mm, for larger components.
  • Page 27 Accessories Insert Utensil Insert Basket Lid D ... Insert tub basket holder basket holder D ... T Ultrasonic bath RK 31 /H K 08 D 08 RK 52 /H K 1 C GH 1 D 52 D 1 T RK 100 /H, K 3 C GH 1 D 100...
  • Page 28 Inset baskets KD ..., PD ..., Sieve cloth. Compatible with inset beakers. Cleaning of small parts. KD 0 Stainless steel Ø interior 75 mm PD 04 Plastic Ø interior 60 mm KD 0 PD 04 Inset beakers SD ... (glass), EB ... (stainless steel), PD ... (plastic) for indirect cleaning of small parts, compatible with positioning lid and beaker holder Ø...
  • Page 29 Accessories Positioning Injection Impression Insert basket Inset beaker lid / beaker Insert basket valve tray holder holders holder Ultrasonic bath RK 31 /H PD 04 KB 04, SD 05 DE 08 SD 06, SD 09, RK 52 /H KD 0, PD 04 DE 52 PK 1 C ED 0...
  • Page 30 Spring clamps EK ..., made of stainless steel, for laboratory fl asks. Prevent them from buoying upwards. To be screwed into insert baskets and utensil holders. EK 10 – 10 ml – max. Ø 31 mm EK 25 – 25 ml – max. Ø 42 mm EK 50 –...
  • Page 31 Accessories Test Silicone Holding clamps for Handle Tabletting Sieve Fixation tube knob laboratory fl asks adjustment punch holder holder clamps holder Ultrasonic bath RK 31 /H EK 10, EK 25, EK 50, RK 52 /H GV 3 RG 2 EK 100, EK 250 RK 100 /H, EK 10, EK 25, EK 50, GV 3...
  • Page 32 Aluminium household foil is also required to conduct the test and is not included in the delivery. Film: http:/ /bandelin.com/folientest/. Example Investigations on test procedures for ultrasonic cleaners. IEC/TR 60886 (1987-03)
  • Page 33 FT 45 600 × 400 × 200 600 × 400 × 200 3204 RK 1050/CH 939x GB/2018-09 2 / 2 BANDELIN electronic GmbH & Co. KG www.bandelin.com Zertifiziert nach Heinrichstraße 3–4 info@bandelin.com ISO 9001 12207 Berlin + 49 30 768 80 - 0...
  • Page 35 Dosing table The dosing table can be requested free of charge in DIN A4 format, or may be downloaded from the Internet as a PDF fi le. http://www.bandelin.com/dosier.htm Fill Bath type Dosage Dosage Dosage Dosage Dosage quantity RK 31 /H 0.6 l...
  • Page 36 Note: These and further languages of this user instructions, as well as further information are to be found on the enclosed CD.

Table of Contents