Riello Steel Pro Power 230-2 P Installation, Technical Assistance Service And System Management Manual
Riello Steel Pro Power 230-2 P Installation, Technical Assistance Service And System Management Manual

Riello Steel Pro Power 230-2 P Installation, Technical Assistance Service And System Management Manual

Table of Contents

Advertisement

Steel Pro Power
EN INSTALLATION, TECHNICAL ASSISTANCE SERVICE AND SYSTEM MANAGEMENT MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Steel Pro Power 230-2 P and is the answer not in the manual?

Questions and answers

Summarization of Contents

Steel Pro Power
Manual Scope
Describes installation, technical assistance, service, and system management.
1 GENERAL INFORMATION
1.1 General Safety Information
Provides essential safety information for installation, operation, and maintenance.
1.2 Precautions
Lists fundamental safety precautions to be respected during appliance operation.
2 INSTALLATION
2.1 Unpacking the product
Guides on unpacking the thermal module and identifying supplied materials.
2.1.1 Positioning of labels
Shows the location of the packing label on the product.
2.3 Installation premises
2.3.1 Recommended minimum distances
Specifies minimum clearances required for assembly and maintenance.
2.7 Typical water system schematics
Block Diagram 1 Connections
Details electrical power and sensor connections for Block Diagram 1.
2.9 Discharge of combustion products
2.9.1 Preparation for the condensate drain
Provides instructions for preparing and installing the condensate drain system.
2.14 Electronic control
2.14.1 Menu structure
Illustrates the multi-level menu navigation of the electronic control interface.
3 COMMISSIONING AND MAINTENANCE
3.1 Initial startup
Guides through the initial startup process, including switching on/off and settings.
3.1.2 Date and time setting
Explains how to set the date, time, and display characteristics.
3.1.3 Password access
Details how to access parameters using different user levels and passwords.
3.1.4 Setting the heating parameters
Explains how to set heating parameters, including operating modes and setpoints.
3.3 Error List
3.3.1 Permanent Errors
Lists permanent errors, their causes, and required actions.
3.3.2 Temporary Errors
Lists temporary errors, their causes, and required actions.
3.9 Maintenance
3.9.1 "Service reminder" function
Explains the service reminder function for planned maintenance alerts.
4 CASCADE CONNECTION
4.1 Preliminary operations
Details preliminary operations required before connecting thermal modules in cascade.
4.1.1 I/O assignment
Explains how to assign I/O management for dependent modules in a cascade.
4.3 Setting the main parameters
4.3.1 Par. 73 – Managing, Stand-alone mode
Defines module addressing and secondary sensor recognition for cascade operation.
4.6 Parameter 148: operating mode of the cascade
4.6.1 Par 148 = 0
Details the start-up/shutdown law for cascade modules in Mode 0.
5 ZONE DEPENDING
5.1 Zone control with Depending module
Explains how to configure thermal elements as zones for system management.
5.2 Setting zone parameters (accessible only with installer password)
Details how to set parameters for connected zones, requiring installer access.
6 MANAGING ADDITIONAL ZONE
6.1 Controlling zone with additional zone accessory
Explains the use of an accessory module for controlling additional heating zones.
7 SYSTEM MANAGER
7.1 Putting into service
Guides the system manager through the initial commissioning and startup procedure.
7.5 Maintenance
3.9.1 "Service reminder" function
Explains the service reminder function for planned maintenance alerts.
8 MODBUS CONNECTION
Registers
Explains Modbus registers for remote management and adjustment.
Control register
Details the function of the control register for enabling writes and resetting the board.
Measurement unit selection register
Explains the register used to change data format for temperature and pressure values.

Table of Contents