Distinctive™ 30” wide wall mount range hood
Hide thumbs Also See for DH3006:

Advertisement

Document # PG07-007
All tolerances: ±1/16" (±1.6 mm), unless otherwise stated
11 7/8 "
(30.2 cm)
OvERALL DIMENSIONS
Filters
2 mesh (baffle type optional, order kit # AHBF2)
Exhaust
8-inch
Total Connect
120 Vac, 60 Hz, 2 Amp. Max. (10.0 Amp Max. surge)
Load
Lights
2, 120 Vac, 75 W each halogen
Fan Rating
600 CFM*
Weight
31 lbs. (14.1 kg)
* A zero inches static pressure
Standard 8" duct
connection
1 1/2"
(3.8 cm)
4 1/8"
3"
(7.6 cm)
(10.5 cm)
All specifications subject to change without notice.
Distinctive™ 30" Wide
Wall Mount Range Hood
29 7/8"
(75.9 cm)
6"
(15.2 cm)
23 5/8"
(60.0 cm)
Specifications
Front of
hood
C L
6 1/8 "
(15.6 cm)
Electrical access holes,
7/8" dia. (5.1 cm)
TOP DIMENSIONS
DH3006S
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
*
25" min.
(63.5 cm)
* Height above cooking surface. The minimum specified distance may be
higher for the particular range or cooktop in use. Check the manufacturers
specifications for the cooktop or range.
Maximum cooking appliance width: 30 inches.
The exhaust duct and electrical wiring are connected from the top of
the hood.
The hood must be centered horizontally over the cooktop/range.
Cabinet storage space located directly above the range should be
avoided.
www.dacor.com
Revised 05/30/12 Page 1/2
PLANNING
GUIDE
warning
30"
(76.2 cm)
Electrical
access
CAbINET LAyOUT