  • Page 1 Installation Instructions Millennia Wall Mount Range Hoods ® Models: DHW301, DHW361, DHW421 and DHW482 ® Approved for use with All dAcor rAnges And cooktops. Part No. 101743 Rev. F...
  • Page 2: Table Of Contents

    ■ The label is located inside the hood chassis behind the filter(s). Remove the filter(s) to view it. All specifications subject to change without notice. dacor assumes no liability for changes to specifications. © 2008 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    Hazards or unsafe practices that could result in ■ Always contact the Dacor Customer Service Team severe personal injury or death. about problems and conditions that you don’t under- stand. cAution Hazards or unsafe practices that could result in minor personal injury or property damage.
  • Page 4: General Safety Precautions

    Important Safety Instructions General Safety Precautions to reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safe- ty precautions, including the following: wArning • If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 5: Installation Specifications

    * At zero inches static pressure Model Specific Maximum Model Blowers lights filters current draw 24” DHW301 3.4 Amp. 30” - 36” - 42” - 48” DHW361 3.4 Amp. DHW421 3.6 Amp. DHW482 6.8 Amp. * 18” 1/4 on model DHW482 with exhaust cowling...
  • Page 6: Planning And Installing The Duct Work

    Installation Specifications Planning and Installing the Duct Calculating the Maximum Duct Run Length The maximum straight duct length for the hood is 50 feet. Work To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from wArning 50 feet.
  • Page 7: Installation Instructions

    In addition, Dacor strongly recommends that you Top of mounting install a reinforced mounting block...
  • Page 8: Installing Chimney Mounting Bracket

    Installation Instructions Installing the Mounting Bracket if mounting the hood to drywall: ■ Drill three appropriate sized pilot holes for the (Continued) mounting hardware being used. The drywall mounting hardware must be purchased sepa- Locate the verti- rately. Hood center cal center line for line the hood mount-...
  • Page 9: Hanging The Range Hood

    Installation Instructions Hanging the Range Hood On models with two blowers: Put the exhaust cowling over the blower outlets on the top of the hood. Fasten the cowling in place with 14 machine screws. Attach the hood junction box to the top of the hood using two machine screws as shown.
  • Page 10: Connecting The Duct Work

    Installation Instructions Connecting the Duct Work Final Chimney Assembly wArning wArning Do not use screws to attach the duct work to the hood Be careful not to pinch the electrical wires while exhaust outlet. Use duct tape only. Screws may prevent assembling the chimney.
  • Page 11: Verifying Proper Operation

    ■ Repeat the above test. ■ If the hood still does not work, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. If you need service, be sure to have the model and serial numbers avail- able when you call.
  • Page 12: Wiring Diagrams

    LIGHT FIXTURES EXTERNAL BLOWER CONNECTION Please note—the layout on the PC Board shown above may vary— however all wires are coded and the connections on the PC Board are also coded with the same number/letters. single Blower Models: dhw301, dhw361, dhw421...
  • Page 13 Wiring Diagrams YELLOW/GREEN MAIN POWER TO BLOWER SWITCH MOTOR TO BLOWER MOTOR TRANSFORMER LIGHT FIXTURES TRANSFORMER LIGHT FIXTURES EXTERNAL BLOWER CONNECTION Please note—the layout on the PC Board shown above may vary— however all wires are coded and the connections on the PC Board are also coded with the same number/letters.