IFM OY422S Operating Instructions Manual
IFM OY422S Operating Instructions Manual

IFM OY422S Operating Instructions Manual

Photoelectric safety sensors (safety light curtain/safety light grid) with ip69k protective tube

Advertisement

Quick Links

Original operating instructions
Photoelectric safety sensors
(safety light curtain / safety light grid)
UK
with IP69K protective tube
Protected area width (range) 0...15 m
OY4xxS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OY422S and is the answer not in the manual?

Questions and answers

Summarization of Contents

Preliminary Note
Symbols Used
Explains the symbols used in the operating instructions.
Warning Signs Used
Details the warning signs and their implications.
Safety Instructions
Safety-Related Application Requirements
Specifies safety requirements for the application of the sensors.
Installation
Installation Instructions
Provides detailed instructions for installing the safety sensors.
Calculation of Minimum Safety Distance
Explains how to calculate the minimum safe distance.
Vertical Installation
Details for vertical installation of safety light curtains/grids.
Safety Light Curtains: 30 mm Resolution
Details for vertical installation of 30 mm resolution safety light curtains.
Safety Light Grids: 2, 3, and 4 Beams
Details for vertical installation of 2, 3, and 4 beam safety light grids.
Horizontal Installation of Safety Light Curtains
Guidance for installing safety light curtains horizontally.
Fixing and Optical Alignment
Covers mounting and aligning the safety sensors.
Optical Alignment
Describes the process of optical alignment for the sensors.
Distance of Reflective Surfaces
Specifies the minimum distance required from reflective surfaces.
Multiple Systems
Guidance on installing multiple safety light systems to avoid interference.
Use of Corner Mirrors
Instructions for using corner mirrors as accessories for U-shaped protection.
Electrical Connection
Wiring Diagram Transmitter
Shows the wiring connections for the transmitter unit.
Wiring Diagram Receiver
Shows the wiring connections for the receiver unit.
Operating Modes
Automatic Operation
Explains the automatic operating mode of the safety light curtains.
Manual Operation
Explains the manual operating mode, including start/restart procedures.
Connection of External Feedback Contacts
How to connect external feedback contacts for operating modes.
Test Function
Details on performing functional tests on the safety light curtains.
Internal Test Function
Describes the internal self-testing capabilities of the sensors.
Operating and Display Elements
LED Indicators for Optical Alignment
Information on using receiver LEDs for correct sensor alignment.
Alignment in the Automatic Mode
How to align sensors in automatic mode using LEDs.
Alignment in the Manual Mode
How to align sensors in manual mode using LEDs.
LED States
Detailed table of LED states for transmitter and receiver.
Operation
Switching State of the Outputs
Describes the binary states of the OSSD outputs.
The Safe State
Defines the safe state for the OSSD outputs.
The Switched State
Describes the switched state of the OSSD outputs.
Interface Classification
Details the interface type and classification of the device.
Functional Test of Safety Light Curtains
Instructions for performing a functional test before operation.
Scale Drawing
Safety Light Curtain Scale Drawing
Provides dimensional drawings for the safety light curtain.
Safety Light Grid Scale Drawing
Provides dimensional drawings for the safety light grid.
Position of Light Beams
Details the position of light beams for different safety light grid models.
Technical Data
Heating
Information regarding heating aspects of the device.
Safety Light Curtains: 30 mm Resolution
Technical data for safety light curtains with 30 mm resolution.
Safety Light Curtains: 40 mm Resolution
Technical data for safety light curtains with 40 mm resolution.
Safety Light Grids: 2, 3, and 4 Beams
Technical data for safety light grids with 2, 3, and 4 beams.
Troubleshooting
Fault Diagnosis Transmitter
Diagnosing faults on the transmitter using LED indicators.
Fault Diagnosis Receiver
Diagnosing faults on the receiver using LED indicators.
Annex
Checklist
A checklist to help with setting up the safety light curtains/grids.

Table of Contents