Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Seametrics Manuals
Measuring Instruments
EX100 Series
Instructions manual
Seametrics EX100 Series Instructions Manual
Insertion magnetic flow meter
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
page
of
20
Go
/
20
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
General Information
Features
Specifications
Installation
Positioning the Meter
Immersion
Chemical Injection or Fertigation
Ex11X/21X Installation
Ex15X/25X Installation
Depth Setting
Pipe Wall Thickness
Straight Pipe Recommendations
Full Pipe Recommendations
Electrical Connections
General Electrical Guidelines
Power
Output
Grounding Guidelines
Connection Diagrams
Counter or PLC
A055 4-20 Ma Output
FT520 Controller
FT430/440 Display & Proportional Feed
FT440 & 4-20 Ma Output
Dual FT430/440 Displays
DL76 Data Logger
Ft440/Dl76
Operation & Maintenance
Zero Adjustment
Minimum Flow
Filtering
Electrode Coating
Calibration ("K-Factor")
Flow Rates in Gallons Per Minute
Parts List
Troubleshooting
Probable Causes
Things to Try
Warranty
Problems
Seametrics Limited Warranty
Advertisement
Quick Links
Download this manual
EX11x
EX21x
PROUDLY
ISO
MADE
IN THE
USA
9001:2008
EX100/200 Series
Insertion Magnetic Flow Meter
EX15x
EX25x
Instructions
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the EX100 Series and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Seametrics EX100 Series
Measuring Instruments SeaMetrics EX11 Series Instructions Manual
Insertion magnetic flow meter (20 pages)
Measuring Instruments SeaMetrics EM 100 Series Instructions
Low-flow magnetic flow meter (4 pages)
Measuring Instruments Seametrics AG90 Quick Start Manual
New meter installation (4 pages)
Measuring Instruments Seametrics EX80 Series Instructions Manual
Electromagnetic flow senso (12 pages)
Measuring Instruments Seametrics EX800 Series Instructions Manual
Electromagnetic flow sensor (16 pages)
Measuring Instruments Seametrics EX Series Manual
(3 pages)
Measuring Instruments Seametrics EM101 Instructions Manual
Low flow magnetic flowmeter (8 pages)
Measuring Instruments SeaMetrics WMP-Series Instructions Manual
Plastic-bodied magmeter (8 pages)
Measuring Instruments SeaMetrics IP100 Series Instructions Manual
Adjustable depth insertion paddlewheel (16 pages)
Measuring Instruments SeaMetrics AG2000 Instructions Manual
Irrigation magmeter (9 pages)
Measuring Instruments SeaMetrics PE202 Instructions Manual
Low flow magmeter (8 pages)
Measuring Instruments Seametrics AG3000 Series Instructions Manual
Irrigation magmeter (24 pages)
Measuring Instruments Seametrics FT440 Instructions Manual
Rate/total indicator (16 pages)
Measuring Instruments SeaMetrics FT420 Manual
(4 pages)
Measuring Instruments Seametrics AG90 Quick Start Manual
(4 pages)
Measuring Instruments Seametrics iMAG 4700r Instructions Manual
Municipal/industrial magmeter (24 pages)
Summarization of Contents
General Information
Product Features
Highlights the key physical components and design aspects of the EX100/200 Series flow meters.
Technical Specifications
Details the technical specifications of the EX100/200 Series, including pipe size, materials, and operating conditions.
Installation
Positioning the Meter
Guidance on optimal placement and orientation of the flow sensor for accurate readings and performance.
Immersion
Information regarding the sensor's limitation for underwater operation and optional immersion features.
Chemical Injection or Fertigation
Recommendations for installing the meter when used with chemical injection or fertigation systems.
EX11x/21x Installation
Detailed steps for installing the EX11x/21x insertion flow meter with 1-1/2 inch FNPT fittings.
EX15x/25x Installation
Procedure for installing the EX15x/25x 'hot tap' models, including pressure installation.
Depth Setting
Instructions on correctly setting the insertion depth (Dimension D) for accurate flow measurement.
Pipe Wall Thickness
Table providing nominal pipe wall thickness for various pipe types and sizes, used for depth setting.
Straight Pipe Recommendations
Diagrams illustrating required upstream and downstream straight pipe lengths for different flow conditions.
Full Pipe Recommendations
Visual examples of pipe configurations to avoid air pockets and ensure full pipe flow for accurate measurement.
Electrical Connections
General Electrical Guidelines
Best practices for wiring, grounding, and avoiding electrical noise for reliable sensor operation.
Power
Details on the required DC power supply specifications for the EX100/200 Series meters.
Output
Explanation of the sensor's pulse output signal characteristics and limitations.
Grounding Guidelines
Instructions for proper grounding of the flow sensor for optimal performance and noise reduction.
Connections Diagrams
Counter or PLC
Wiring diagram showing how to connect the EX-Series sensor to a Counter or PLC digital input.
AO55 4-20 mA Output
Diagram illustrating the connection of the EX-Series sensor to an AO55 for 4-20 mA output.
FT520 Controller
Wiring diagram for connecting the EX-Series sensor to an FT520 controller.
FT430/440 Display and Proportional Feed
Diagram for connecting the EX-Series sensor to an FT430/440 for display and proportional feed.
FT440 Display and 4-20 mA Output
Wiring diagram showing connection of EX-Series sensor to FT440 for display and 4-20 mA output.
Dual FT430/440 Displays
Example of a bidirectional connection diagram for dual FT430/440 displays.
DL76 Data Logger
Diagram illustrating the connection of the EX-Series sensor to a DL76 data logger.
FT430/440 and DL76
Wiring diagram for connecting the EX-Series sensor to both FT430/440 and DL76.
Operation & Maintenance
Zero Adjustment
Procedure for adjusting the sensor's zero point when there is no flow.
Minimum Flow
Information on the minimum flow rate detectable by the sensor for various pipe sizes.
Presence of Flow Indication
Explanation of the 'Status LED' blinking modes for indicating flow presence or absence.
Filtering
How the sensor software filters electrical noise and averages flow variations for a smooth output.
Electrode Coating
Guidance on cleaning electrodes if they become coated with grease or other adhering materials.
Calibration ('K-Factor')
Explanation of the K-factor and how to obtain and enter it for accurate pulse processing.
EX 11x/21x Parts
List of replacement parts for the EX 11x/21x series, including part numbers and housing options.
EX 15x/25x Parts (Hot Tap)
List of replacement parts specific to the EX 15x/25x 'Hot Tap' models, including part numbers.
Troubleshooting
No pulse output
Common causes and solutions for the issue of the flow meter not producing any output pulses.
Output pulses incorrect
Troubleshooting steps for when the flow meter's output pulses are not accurate or are missing.
Jumpy readings
Causes and remedies for fluctuating or unstable flow readings, often related to conductivity changes.
Seametrics Limited Warranty
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the EX100 Series and is the answer not in the manual?
Questions and answers