Troubleshooting; Please Read The Following Carefully - Chicago Electric Power Systems 96706 Set Up And Operating Instructions Manual

5000w continuous/10,000w surge power inverter
Table of Contents

Advertisement

Problem
LO
HI
OL
OH
No output voltage.
Output voltage is
incorrect
Could not drive load
Picture is full of static
or speakers make a
buzz

Please read the FolloWing CareFullY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED AN ASSEMBLy DIAGRAM IN THIS
MANUAL AS A REFERENCE TOOL ONLy. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANy REPRESENTATION OR WARRANTy OF ANy KIND TO THE BUyER THAT HE OR SHE
IS qUALIFIED TO MAKE ANy REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS qUALIFIED TO
REPLACE ANy PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR
ExPRESSLy STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN
By CERTIFIED AND LICENSED TECHNICIANS, AND NOT By THE BUyER. THE BUyER ASSUMES
ALL RISK AND LIABILITy ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT
OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF
REPLACEMENT PARTS THERETO.
SKU 96706
For technical questions, please call 1-800-444-3353.

troubleshooting

Possible Causes
Low input voltage
High input voltage
Overload
Overheat
Cords not connected properly
Input voltage is too high or too
low
1.
Load power is too large
2.
Load is actually larger than
rated
3.
The AWG of the wire is too
low
4.
Start power of an appliance
is up to twice the rated
power.
Television or radio
interference
Probable solutions
Recharge or Replace Battery
Battery voltage is too high. Remove charging
source and make sure correct battery is being
used.
Excessive load at AC output. Reduce load to
less than rated power.
Internal temperature is too high. Let the
Inverter cool down for at least 30 minutes.
Make sure that the fan is not blocked and that
the Inverter has sufficient ventilation.
Check connections and secure
Check all devices and maintain voltage at
required level
1.
Lower load level
2.
Lower load level
3.
Use 00 AWG wire connections
4.
Reduce load, or change appliances
Move Inverter away from antenna and/or use a
shielded antenna cable.