Eaton HotSwap MBP Series Installation And User Manual
Eaton HotSwap MBP Series Installation And User Manual

Eaton HotSwap MBP Series Installation And User Manual

Maintenance bypass
Hide thumbs Also See for HotSwap MBP Series:

Advertisement

Copyright © 2012 EATON
All rights reserved.
Service and support:
Call your local service representative
SK-90610-Y4_EN
HotSwap MBP
Maintenance Bypass
MBP6K208
MBP11K208
Installation
and user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HotSwap MBP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton HotSwap MBP Series

  • Page 1 HotSwap MBP Maintenance Bypass MBP6K208 MBP11K208 Installation and user manual Copyright © 2012 EATON All rights reserved. Service and support: Call your local service representative SK-90610-Y4_EN...
  • Page 2 SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the MBP and UPS. The Hotswap MBP models that are covered in this manual are intended for installation in an environment within 0 to 40°C, free of conductive contaminant. This equipment has been tested and found to comply with Class A UPS,pursuant to Part 15 of the FCC Rules.
  • Page 3 The admissible storage temperature range is -15ºC to +60ºC. Special precautions p The Hotswap MBP is designed to work with approved EATON UPS (contact your Eaton reseller for more information) p All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY.
  • Page 4: Table Of Contents

    3.4 Mechanical Mounting ...................... 10 3.5 Installation requirements ....................10 4. Power cables connection ..............11 4.1 MBP6K208 ........................11 4.2 MBP11K208 ........................12 5. Operations ..................14 5.1 UPS start-up with HotSwap MBP ..................14 5.2 UPS replacement with HotSwap MBP ................15 5.3 UPS maintenance with HotSwap MBP ................
  • Page 5: Introduction

    Before installing your HotSwap MBP with your UPS, please read first the safety instructions. Then follow the indications in this manual, which completes the UPS Installation and User Manual. To discover the entire range of EATON products, we invite you to visit our web site at www.eaton.com/ powerquality or contact your EATON representative.
  • Page 6: Presentation

    2. Presentation The Eaton® HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads (HotSwap function). You can safely eliminate the effects of UPS maintenance and guard the integrity of your equipment.
  • Page 7 2. Presentation MBP11K208 Tower installation Rack installation Wall mounting Description Weight Dimensions (inch/mm) (lb/kg) D x W x H MBP6K208 5.5 / 2.5 4.3 x 7.0 x 5.1 / 110 x 177 x 130 MBP11K208 13.7 / 6.2 8.7 x 13.2 x 5.1 / 220 x 336 x 130...
  • Page 8: Description / Panels

    MBP status, and the indication on UPS display panel of both following status: p MBP connection to UPS p Bypass switch position Check the UPS user manual to check the compatibility of this feature, or contact Eaton reseller for more information MBP6K208...
  • Page 9: Installation

    (including square nuts ans screws) (5) Tower and wall mouting kit (including 2 ears and screws) (6) Installation and user manual MBP11K208 (1) MBP I/O cover (2) MBP I/O "UPS connection" cover (3) (2) conduits with internal wires for UPS Input/Output connection...
  • Page 10: Mechanical Mounting

    6 mm (10 AWG) 105°C Phase MBP6K208 10 lb in (20-8 AWG) 10 mm (8 AWG) 75°C Ground Phase MBP11K208 4-25 mm 10 mm (8 AWG) 105°C Phase with 18 lb in (12-4 AWG) 16 mm (6 AWG) 75°C 8kVA UPS...
  • Page 11: Power Cables Connection

    3. Connect the MBP detection cable from the I/O cord Set (1) to the specific UPS connector (MBP detect, refer to UPS User Manual). Only with compatible EATON UPS, contact your Eaton reseller for more information. 4. Slide the MBP I/O cover (2) after removing the 4 screws, to access to MBP terminal blocks.
  • Page 12: Mbp11K208

    13. Connect the MBP detection cable (6) to the specific UPS connector (MBP detect, refer to the UPS User Manual). Only with compatible EATON UPS, contact your Eaton reseller for more information. 14. Put back and secure the I/O terminal blocks cover of the UPS - refer to the UPS user manual.
  • Page 13 4. Power cables connection 16. Punch the knockouts of MBP I/O cover (1) and insert cable glands of UPS (or conduit fittings) inside. 17. Insert the Normal AC source cable through the cable gland (or a conduit through the conduit fitting). 18.
  • Page 14: Operations

    5. Operations 5.1 UPS start-up with HotSwap MBP Verify that the total equipment ratings do not exceed the UPS capacity to prevent an overload alarm. 1. Check that the UPS is correctly connected to the HotSwap MBP (see previous chapter 4) If the UPS if equipped with outlets, those outlets can no longer be used (loads can only be connected to the MBP outlets or the MBP Output terminal blocks).
  • Page 15: Ups Replacement With Hotswap Mbp

    5. Operations 5.2 UPS replacement with HotSwap MBP UPS Removing (please follow the MANDATORY step below): MBP6K208: 1. Put the UPS in “internal Bypass mode” (refer to the UPS user manual) 2. Verify that the UPS is on Bypass mode by checking UPS display panel (refer to the UPS user manual) BYPASS 3.
  • Page 16 5. Operations MBP11K208: 1. Put the UPS in “internal Bypass mode” (refer to the UPS user manual) BYPASS 2. Verify that the UPS is on Bypass mode by checking UPS display panel (refer to the UPS user manual) 3. Set the MBP manual Bypass switch to "Bypass" position. The "Bypass mode" red light of the MBP goes On, indicating that the load is supplied directly by AC source 4.
  • Page 17: Ups Maintenance With Hotswap Mbp

    Connect the I/O cord Set (1) connector to the MBP , and secure it by fixing the 2 locking screws MBP11K208: p First check that the Normal AC source switch (3) of the MBP is still locked to the "0" position...
  • Page 18: Specifications

    6. Specifications MBP6K208 MBP11K208 Input Terminal blocks Output 2 L6-30R + Terminal blocks 3 L6-30R + Terminal blocks Overall dimensions D x W x H (inch / mm) 5.6 x 7.0 x 5.1 / 10.2 x 13.2 x 5.1 /...

Table of Contents