Eaton CBC-8000 Installation And Operation Instruction Manual
Eaton CBC-8000 Installation And Operation Instruction Manual

Eaton CBC-8000 Installation And Operation Instruction Manual

Capacitor bank control
Table of Contents

Advertisement

Energy Automation Solutions
MN916001EN
MN916001EN
CBC-8000 capacitor bank control installation and operation
instructions
Effective October 2018
New Information
COOPER POWER
Effective October 2018
Supersedes October 2016
SERIES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBC-8000 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety Information and Precautions
Safety Information Overview
Provides general safety context and emphasizes the need for competent technicians.
Key Safety Instructions
Highlights critical safety instructions and general warnings applicable to the equipment.
Hazard Statement Definitions
Explains the meaning of DANGER, WARNING, CAUTION, and NOTICE statements used in the manual.
Product Information
Introduction to CBC-8000 Control
Provides installation and operation instructions for the CBC-8000 capacitor bank control.
Manual Reading Guidance
Instructs users to read and understand the manual before installing or operating the equipment.
Obtaining Additional Information
Explains how to get more details or assistance for issues not covered in the manual.
Compliance Standards
Lists standards the CBC-8000 control is designed and tested according to.
Acceptance and Initial Inspection
Details factory testing and inspection procedures upon receipt of the control.
Handling and Storage Guidelines
Provides guidance on careful handling and storage to prevent damage.
CBC-8000 Control Specifications
Lists technical specifications for the CBC-8000 control, including temperature, power, and size.
CBC-8000 Capacitor Bank Control Description
Description of CBC-8000 Control
Details the extensive system control functionality and design of the CBC-8000 capacitor bank control.
Serial Number and Date Code Location
Explains where to find the serial number and date code for warranty and identification purposes.
Enclosure Features
Describes various physical features of the CBC-8000 control enclosure, such as door sensor and latch.
Front Panel Overview
Describes the CBC-8000 control's front panel, divided into programming and operating sections.
Programming Panel Details
Details the programming panel, including the LCD display, keypad, and their functions.
LCD Display and Keypad Functionality
Explains the operation of the LCD display and the functionality of each button on the keypad.
Status and Indicator LEDs
Explains the meaning of the status indicator LEDs for control and capacitor bank status.
Data Port
Details the front panel USB data port used for communication with personal computers.
Operating Panel Controls
Describes the function of buttons on the operating panel, including TRIP, CLOSE, and one-touch function buttons.
Mode of Operation Settings
Explains how to set the control's operational mode using Manual, Remote, and Auto buttons.
Secondary Function Buttons
Describes the function of buttons for Neutral Lockout Reset, Tracking, and Alarms.
Control Features and Security
Lists standard features and details customer-programmable security codes and password recovery.
Operating Modes: Remote and Automatic
Explains how to operate the capacitor bank remotely and automatically based on local conditions.
Adaptive Voltage Sensing
Details the predictive algorithm for preventing OVUV or emergency voltage conditions during control operations.
Alarming and Priority Control
Explains how the control sets alerts and how control methods are prioritized.
Control Strategies: VAR, Temperature, Sensor Input
Details control based on VAR, temperature, and sensor input values and thresholds.
Advanced Control Features
Covers current control, neutral current fault control, verification, and communications loss control.
Neutral Current Monitoring Comparison
Compares Neutral Current Fault Control and Neutral Current Verification features.
Communication Ports and Modules
Describes communication ports and SelectComm modules for connectivity.
Ethernet Module Specifications
Lists connectors, LEDs, and PoE capability for the Ethernet SelectComm module.
Ethernet Connectivity Details
Provides Ethernet cable wiring and status LED information.
Radio Modems
Lists various radio modems available for use with the CBC-8000 control.
Installation Procedure
Initial Programming Prior to Installation
Emphasizes programming the control with settings before connecting to an energized capacitor bank.
Mounting the Control
Provides general guidance on mounting the control in an accessible location, including dimensions.
Power Transformer Recommendation
Recommends sizing power transformers for the CBC-8000 and capacitor switches based on application needs.
Installing the Control
Outlines the steps for installing the control, including distance measurement and grounding.
Control Mounting Configurations
Explains how to determine the control's mounting configuration from its style number.
Mounting Options and Styles
Details various mounting styles (socket mount, pole mount) and their corresponding jaw configurations.
DIN Connector Options Overview
Lists the four available DIN connector options for connecting sensors and controls.
5-Pin DIN Connector
Describes the legacy 5-pin DIN connector for basic trip, close, and power functionality.
7-Pin DIN Connector
Explains the legacy 7-pin DIN connector supporting two external sensors.
8-Pin DIN Connector (Sensor Inputs Only)
Details the 8-pin DIN connector used exclusively for sensor inputs, supporting 3-phase measurements.
14-Pin DIN Connector (3-Phase Metering/Control)
Describes the 14-pin DIN connector for powering, control, and measurements.
Wiring Harness Options
Lists available cable assemblies and their associated DIN pin assignments and wire colors.
5 Wire Harness Details
Details the 5-wire harness used with the 5-pin DIN connector.
7 Wire Harness Details
Details the 7-wire harness used with the 7-pin DIN connector.
14 Wire Harness Details
Details the 14-wire harness used with the 14-pin DIN connector.
Socket Mount Installation
Provides step-by-step instructions for installing the control into a meter socket.
Pole Mount Installation Overview
Explains the requirements for pole mount installations, including bracket installation.
Performing Pole Mount Installation
Details the steps for physically installing the CBC-8000 control onto a utility pole.
Installing the Pole Mount Bracket
Describes how to attach the pole mount bracket to the CBC enclosure.
Panel Mount Installation Overview
Explains the requirements for panel mount installations and ordering the necessary bracket.
Installing the Panel Mount Bracket
Details how to install the panel mount bracket onto the CBC enclosure.
Performing Panel Mount Installation
Provides steps for physically installing the CBC-8000 control onto a panel.
Installing the Cable Security Sleeve
Details the installation of an optional cable security sleeve to protect connections from tampering.
Storm Trapper Installation
Recommends installing the optional Storm Trapper surge arrester for protection.
Cable Security Sleeve Installation Steps
Provides step-by-step instructions for installing the cable security sleeve.
Eaton's Cooper Power Series Junction Box Installation
Explains how to use junction boxes for wiring the control to switches and sensors.
SelectComm Module Installation
Installing SelectComm Modules
Provides step-by-step instructions for installing serial or Ethernet SelectComm modules into the CBC-8000 control.
Radio Modem Installation
Mounting Space for Radio Modem
Shows the available space for mounting a radio modem on the CBC-8000 control's document holder.
Installing a Radio Modem
Details the procedure for mounting and connecting a radio modem to the CBC-8000 control.
Before Placing the Control into Service
Pre-Service Verification Steps
Lists essential checks and verifications before energizing the control and capacitor bank.
Testing Procedures
Testing an Installed Control
Provides steps to verify that the installed control is operating correctly.
Removing Control from Service Overview
Describes the process of taking the control out of service for maintenance or replacement.
Removing Socket Mount Control
Details the steps to safely remove a socket-mounted control from service.
Removing Pole Mount Control
Provides instructions for safely removing a pole-mounted control from service.
Removing Panel Mount Control
Details the steps to safely remove a panel-mounted control from service.
Approved Sensor Manufacturers
Line Post Sensor Information
Lists tested line post sensors that provide accurate current measurements.
Neutral Current Sensor Details
Describes the optional CBC-NCSENSOR-35 and CBC-NCSENSOR8P-35 neutral current transducers.
Additional Information
Replacement Kits
Explains how to obtain replacement kits for the control through the factory Service Department.
Factory-Authorized Service Centers
Provides information on locating service centers for maintenance, repair, and testing.

Table of Contents

Save PDF