Advertisement

We,
Hisense(Shandong) Air-conditioning Co.,Ltd.
No.8 Ronggang Road, Ronggui, Shunde,Foshan, Guangdong, P.R.China
No.1 Hisense Road, Nancun, Pingdu,Qingdao, Shandong Province, P.R.China
declare under our sole responsibility that the product
to which this declaration relates is in conformity with the technical requirements of the
following standard(s)
EMC Directive- 2014/30/EU
Low Voltage Directive-2014/35/EU
CE Marking Directive-93/68/EEC
LVD standard
EN 60335-1:2012+A11:2014
EN 60335-2-40:2003
+A11:2004+A12:2005+A1:2006+A2:2009
+A13:2012
EN 62233:2008
Hisense International Co., Ltd
( Supplier Address & Factory Address )
AIR CONDITIONER
(Category Name)
GBF18H-S
GDF18H-S
GBF24H-S
GDF24H-S
GBF36H-S
GDF36H-S
GBF48H-S
GDF48H-S
GBF60H-S
GDF60H-S
(Model Name)
GFF18H-S
GCF18H-S
GFF24H-S
GCF24H-S
GFF36H-S
GCF36H-S
GFF48H-S
GCF48H-S
GFF60H-S
GCF60H-S
EMC standard
EN 55014-1:2006
+A1:2009+A2:2011
EN 55014-2:1997 +A1:2001+A2:2008
EN 61000-3-2:2014
EN 61000-3-2:2014
EN 61003-3-3:2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUV-24HR4SA and is the answer not in the manual?

Questions and answers

Summarization of Contents

1. GENERAL
1-1 Features
Key features of Duct, Cassette, and Ceiling & Floor types.
1-2 Product Lineup
Overview of available product models across different types.
1-3 Model Identification
Explanation of the model naming convention and structure.
1-4 Product Pictures
Visual illustrations of indoor and outdoor units by type.
Display Panel Information
Details on the unit's display panel indicators and functions.
2. SPECIFICATIONS
Duct Type Specifications
Technical specifications for Duct Type Indoor Units.
Cassette Type Specifications
Technical specifications for Cassette Type Indoor Units.
Ceiling & Floor Type Specifications
Technical specifications for Ceiling & Floor Type Indoor Units.
Universal Outdoor Unit Specifications
Technical specifications for Universal Outdoor Units.
3. OUTLINES AND DIMENSIONS
Indoor Unit Dimensions
Dimensional drawings and measurements for indoor units by type.
Outdoor Unit Dimensions
Dimensional drawings and measurements for outdoor units by capacity.
4. DIAGRAM&DATA
Piping and Electrical Diagrams
Illustrates refrigerant piping and electrical wiring configurations.
Refrigerant Pipe Installation Guidelines
Guidelines for refrigerant pipe length and height difference.
Performance Charts and Curves
Air flow/ESP charts and performance curves for various models.
5. ELECTRICAL DATA
Wiring Diagrams and Control Boards
Electrical wiring diagrams and control board component layouts.
Unit Configuration and Settings
Dip switch settings, parameter adjustment, and static pressure configuration.
Sensor Parameter Data
Resistance values for temperature sensors at various temperatures.
6. CONTROL MODE
Indoor Control Mode Functions
General parameters and functions for indoor unit control modes.
Outdoor Mode Control
Control functions and protection mechanisms for outdoor units.
7. TROUBLE SHOOTING
Checking Fault Codes
Methods to identify and display error codes on unit interfaces.
Unit Error Code Tables
Comprehensive lists of indoor/outdoor unit and driver board fault codes.
8. CHECKING COMPONENTS
Refrigerant System Check
Procedure for testing the refrigerant system's operational status.
Motor Testing Procedures
Guides for testing indoor/outdoor fan motors and compressors.
Electrical Component Testing
Methods for testing fuses, capacitors, and stepper motors.

Table of Contents