Honeywell VISTA-250BP Installation And Setup Manual
Honeywell VISTA-250BP Installation And Setup Manual

Honeywell VISTA-250BP Installation And Setup Manual

Commercial burglary partitioned security systems
Hide thumbs Also See for VISTA-250BP:
Table of Contents

Advertisement

V V V V
I I I I
S S S S
V V V V
I I I I
S S S S
K5894V5 6/04 Rev A
WWW.DIYALARMFORUM.COM
A A A A
D D D D
E E E E
M M M M
C C C C
A A A A
D D D D
E E E E
M M M M
C C C C
T T T T
A A A A
- - - -
1 1 1 1
2 2 2 2
8 8 8 8
T T T T
A A A A
- - - -
1 1 1 1
2 2 2 2
8 8 8 8
Partitioned Security System
Partitioned Security System
Partitioned Security System
Partitioned Security System
Installation and Setup Guide
WWW.DIYALARMFORUM.COM
O O O O
V V V V
I I I I
S S S S
T T T T
O O O O
V V V V
I I I I
S S S S
T T T T
B B B B
P P P P
/ / / /
V V V V
I I I I
S S S S
B B B B
P P P P
/ / / /
V V V V
I I I I
S S S S
V V V V
I I I I
S S S S
V V V V
I I I I
S S S S
Commercial Burglary
Commercial Burglary
Commercial Burglary
Commercial Burglary
With Scheduling
With Scheduling
With Scheduling
With Scheduling
A A A A
S S S S
E E E E
R R R R
A A A A
S S S S
E E E E
R R R R
T T T T
A A A A
- - - -
2 2 2 2
5 5 5 5
0 0 0 0
T T T T
A A A A
- - - -
2 2 2 2
5 5 5 5
0 0 0 0
T T T T
A A A A
- - - -
1 1 1 1
2 2 2 2
8 8 8 8
T T T T
A A A A
- - - -
1 1 1 1
2 2 2 2
8 8 8 8
I I I I
E E E E
S S S S
I I I I
E E E E
S S S S
B B B B
P P P P
/ / / /
B B B B
P P P P
/ / / /
S S S S
I I I I
A A A A
S S S S
I I I I
A A A A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VISTA-250BP and is the answer not in the manual?

Questions and answers

Summarization of Contents

Conventions Used in This Manual
UL Notes
Notes with specific information for UL Listed applications.
Programming Prompts
Explanation of interactive keypad prompts used in programming.
SECTION 1: General Description
About the VISTA-128BP/VISTA-250BP
Overview of the control panel and its key features.
Features
Lists key capabilities of the VISTA-128BP/VISTA-250BP.
Hardwire and Optional Expansion Zones
Details zone capabilities and expansion options.
Partitioning and Panel Linking
Controls 8 areas independently and links multiple panels.
Scheduling
Automates system functions like arming and relay activation.
Downloading
Supports upload and download capabilities for system management.
SECTION 2: Partitioning and Panel Linking
Theory of Partitioning
Explains the concept and benefits of system partitioning.
Setting-Up a Partitioned System
Outlines the steps for configuring a partitioned system.
Common Lobby Logic
Logic for automated arming/disarming of a common lobby partition.
SECTION 3: Installing the Control
Mounting the Control Cabinet
Provides step-by-step instructions for cabinet installation.
Installing the Keypads
Details wiring and connecting keypads to the control panel.
Installing External Sounders
Covers wiring and configuration of external sounders.
Telephone Line Connections
Details connecting the dialer to the telephone network.
Using 2-Wire Smoke Detectors on Zone 1
Instructions for wiring 2-wire smoke detectors.
Using 4-Wire Smoke Detectors on Zones 1-8
Instructions for wiring 4-wire smoke detectors.
Installing RPM Devices
Instructions for installing Polling Loop devices.
Wireless Zone Expansion
Explains using wireless receivers for expanding system zones.
Installing Output Devices
Details installation of devices providing system outputs.
Installing the VA8200 Panel Link Module
Provides steps for module installation and wiring.
Installing the Alpha Pager Module
Details installation of the module for alphanumeric messages.
Access Control Using VistaKey
Step-by-step guide for installing the VistaKey module.
Access Control Using the PassPoint Access Control System
Explains interfacing with the PassPoint ACS.
Installing the 4285/4286 VIP Module
Details installation of the VIP module for phone access.
Installing TeleSmart
Covers installation of the TeleSmart telephone interface.
Connecting the Transformer
Details how to connect the power transformer.
Determining the Control’s Power Supply Load
Calculation of power load for system components.
Determining the Size of the Standby Battery
Guidance on calculating required battery capacity.
SECTION 4: Programming
Program Modes
Explains Data Field and #93 Menu programming modes.
Entering and Exiting Programming Mode
How to access and leave programming mode.
Data Field Programming Mode
Description of programming via data fields.
#93 Menu Mode Programming
Details the interactive menu programming system.
ZONE PROG?
Configuration for zone parameters.
DEVICE PROG?
Configuration for device characteristics.
OUTPUT PGM?
Configuration for output device functions.
Zone Response Type Definitions
Explains different zone response types and their functions.
Zone Input Type Definitions
Defines how the system interprets zone input signals.
Programming for Panel Linking
Steps to integrate multiple control panels.
Programming for the Alpha Pager Module
Configuration for sending messages to pagers.
Programming for Access Control
Details programming for VistaKey and PassPoint.
SECTION 5: Data Field Descriptions
About Data Field Programming
Introduction to data field programming concepts.
Programming Data Fields
How to access and enter data field values.
*22 Keypad Panic Enables (partition specific)
Enables panic functions for keypads per partition.
*28 Power-Up in Previous State
Configures system behavior upon power restoration.
*29 Quick Arm (partition-specific)
Allows arming without a user code.
*33 Primary Phone Number
Sets the primary number for central station communication.
*34 Secondary Phone Number
Sets the backup number for communication.
*35 Download Phone Number
Sets the number for remote downloading.
*45 Primary Format
Selects the primary reporting format for central station.
*47 Secondary Format
Selects the secondary reporting format.
*51 Dual Reporting
Enables sending reports to both primary and secondary numbers.
*52 Standard/Expanded Reporting Primary
Configures primary reporting detail level.
*53 Standard/Expanded Reporting Secondary
Configures secondary reporting detail level.
*54 Unattended Mode
Enables automatic system downloads.
1*20 Exit Error Logic Enable
Manages exit error logic for preventing false alarms.
1*21 Exit Delay Reset
Allows resetting exit delay for user re-entry.
Cross-Zoning
Explains how to link zones for enhanced security.
1*22 Cross Zoning Pair One
Configures the first pair of cross-zoned devices.
1*23 Cross Zoning Pair Two
Configures the second pair of cross-zoned devices.
1*24 Cross Zoning Pair Three
Configures the third pair of cross-zoned devices.
1*25 Cross Zoning Pair Four
Configures the fourth pair of cross-zoned devices.
2*05 Auto-Arm Delay (partition specific)
Sets delay for automatic partition arming.
2*06 Auto-Arm Warning Period (partition-specific)
Sets warning time before auto-arming.
2*07 Auto-Disarm Delay (partition specific)
Sets delay for automatic partition disarming.
2*08 Force Arm Enable for Auto-Arm (partition-specific)
Enables force arming during auto-arm.
SECTION 6: Scheduling Options
General
Overview of scheduling features and their purpose.
Auto Arming
Explains the system's automatic arming capabilities.
Auto Disarming
Explains the system's automatic disarming capabilities.
Exception Reports
Controls reporting of openings/closings by exception.
Time Window Definitions
Defines time periods for scheduled events.
Daily Open/Close Schedules
Assigns daily open/close times per partition.
Time-Driven Events
Automates actions based on time windows.
User Scheduling Menu Mode
Allows end-users to control output devices via timers.
SECTION 7: Downloading Primer
General Information
Overview of remote downloading and its requirements.
Access Security
Details the four levels of protection for remote access.
Getting On-Line with a Control Panel
Steps to establish a remote connection to the panel.
On-Line Control Functions
Lists functions performable remotely via the downloader.
Scheduled Download
Enables programming for automatic scheduled downloads.
Direct-Wire Downloading
Method for downloading without a modem or phone line.
SECTION 8: Setting the Real-Time Clock
General Information
Explains the importance of the real-time clock.
Setting the Time and Date
Step-by-step guide to set the system clock.
SECTION 9: User Access Codes
General Information
Overview of security codes and user management.
User Codes & Levels of Authority
Explains assigning different authority levels to users.
Level 0: Installer (User 1) Code
Details the Installer Code's functions and restrictions.
Level 1: Master Codes
Describes the functions and capabilities of Master Codes.
Level 2: Manager Codes
Details the functions and limitations of Manager Codes.
Level 3-5: Operator Codes
Explains the functions of Operator Codes A, B, and C.
Level 6: Duress Codes
Describes the silent alarm function for duress situations.
Multiple Partition Access
Explains how users can be granted access to multiple partitions.
Adding a Master, Manager, or Operator Code
Step-by-step guide to adding new user codes.
Deleting a Master, Manager, or Operator Code
Procedure for removing existing user codes.
SECTION 10: Testing the System
Battery Test
How the system performs battery checks.
Dialer Test
Procedure for programming automatic test reports.
Burglary Walk-Test (Code + [5] TEST)
Steps for performing a burglary zone test.
Armed Burglary System Test
Procedure for testing the system while armed.
Testing Wireless Transmitters
How to test wireless components.
Trouble Conditions
Explains various system trouble messages.
To the Installer
Installer responsibilities for system maintenance.
APPENDIX A: Regulatory Agency Statements
UL Installation Requirements
Key requirements for UL installations.
UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault
Guidelines for specific commercial installations.
UL365 Police Station Connected Burglar Alarm
Requirements for police station linked alarms.
UL611/UL1610 Central Station Burglary Alarm
Requirements for central station alarms.
FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT
FCC compliance statement for digital devices.
FCC PART 68 NOTICE
FCC notice regarding telephone connection requirements.
CANADIAN EMISSIONS STATEMENTS
Compliance statement for Canadian emissions.
APPENDIX B: Summary of System Commands
User Code Commands
List of commands for managing user codes.
Programming Commands
Commands for accessing and navigating programming modes.
Event Logging Commands
Commands for managing the event log.
Wireless System Commands
Commands related to wireless transmitter functions.
Additional Commands
Miscellaneous system commands.
Output Device Control Commands
Commands for controlling system outputs.
Scheduling Commands
Commands for configuring system schedules.
Access Control Commands
Commands for managing access control features.
Panel Linking Commands
Commands for managing panel linking.
APPENDIX C: Specifications
VISTA-128BP/VISTA-250BP CONTROL
Physical and electrical specifications for the control panel.
Remote Keypads
Physical and electrical specifications for keypads.
APPENDIX D: Contact ID and Pager Event Codes
TABLE OF CONTACT ID EVENT CODES
List of event codes for Contact ID reporting.
Event Log and Pager Alpha Descriptors
Descriptions for event log and pager messages.
Alpha Event Description
Descriptions for various alpha-formatted events.
Access Control Events
Event codes specific to access control functions.

Table of Contents

Save PDF