Service Literature
CBX32MV (HFC-410A) SERIES UNITS (iComfort
NOTICE
A thermostat is not included and must be ordered
separately.
D A Lennox iComfort
®
communicating applications.
D In
non-communicating
®
ComfortSense
7000 thermostat may be used, as well
as other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 24.
WARNING
Improper installation, adjustment, alteration, service or
Maintenance can cause personal injury, loss of life, or
damage to property.
Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take care
while handling this equipment and use protective cloth­
ing.
Revised April 7, 2015
thermostat must be used in
applications,
the
Lennox
Corp. 1005-L2

TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Upflow/Downflow Unit Dimensions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Code Recall Mode
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This indoor unit is designed for installation with optional
field-installed electric heat and a matched remote outdoor
unit that is charged with HFC-410A refrigerant. These units,
designed for indoor installation in multiple positions, are
completely assembled for upflow and horizontal right-hand
discharge before being shipped from the factory.
All CBX32MV air handlers are equipped with a
factory-installed, internally mounted check expansion
valve (CTXV), which is suitable for use in HFC-410A
applications.
This air handler is compatible with the ComfortSense® 7000
non-communicating thermostat and non- communicating
outdoor units. In addition, newer model units have the
enhanced capability of communicating with iComfort
thermostats and compatible outdoor units using the Lennox
RSBus protocols.
NOTE - For downflow or horizontal left-hand air discharge,
certain field modifications are required.
This document provides information only on the
CBX32MV-XXX-230-6-06 and later which features the new
iComfortt-enabled hardware. Refer to Corp. 0206-L3 for
earlier model service related information.
Page 1
CBX32MV
®
-enabled)
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
2015 Lennox Industries Inc.
2
3
3
9
13
14
15
15
15
19
22
23
23
24
. .
31
36
43
44
44
45
45
45
47
60
66
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBX32MV-024/030 and is the answer not in the manual?

Questions and answers

Summarization of Contents

CBX32MV Upflow and Downflow Unit Dimensions
CBX32MV Model Dimensions (Upflow, Downflow, Left- and Right-Hand Horizontal applications)
Details dimensions for various CBX32MV models in upflow, downflow, and horizontal configurations.
General Installation Information
Installation Clearances
Specifies minimum clearances required for cabinet, plenum, and duct installations.
Installation Requirements
Outlines requirements for unit installation, including configuration and field modifications.
Horizontal Right-Hand Discharge Application
In High Humidity Areas
Recommendations for horizontal applications in high humidity to ensure proper condensate removal.
Field Modification for Left-Hand Discharge
Horizontal Left-Hand Discharge Application
Procedures for configuring the unit for horizontal left-hand discharge operations.
Condensate Drain Requirements
Main Drain
Instructions for connecting and routing the main drain line.
Overflow Drain
Recommendations and requirements for connecting the overflow drain line.
Best Practices
Recommended practices for ensuring effective condensate removal.
Field Control Wiring
Wiring Connections
Details on making electrical connections for power supply, grounding, and low voltage wiring.
Sensor and Control Connections
Discharge Sensor (DAT)
Information on the discharge air sensor, its function, and installation.
Outdoor Air Sensor
Details regarding the outdoor air sensor connection and specifications.
Air Handler Control 9-Pin Connector (P8)
Description of the 9-pin connector and its wiring for air handler control.
Air Handler Control Button, Display and Jumpers
Jumpers
Explanation of jumper settings for humidification, heat mode, blower speed, and adjustments.
Display
Information on the single-character LED display for system status, modes, and error codes.
Configuring Unit
Air Handler Control Checkout
Steps for checking the air handler control configuration and setup.
Blower and System Checks
Indoor Blower Test
Procedure to test the indoor blower motor operation.
Checkout Procedures
Comprehensive checklist for pre-start-up, blower, and cooling operation checks.
Unit Operation Details
Operation Modes
Explains cooling, heating (electric/heat pump), and emergency heat modes.
Maintenance Procedures
Routine maintenance tasks for outdoor unit, outdoor coil, and indoor unit.
Cabinet Insulation
Repairing Damaged Insulation
Instructions for repairing or replacing damaged insulation to prevent condensation.
Optional Electric Heat (ECB40)
A-Matchups and Ratings
Details on approved matchups and electrical ratings for CBX32MV and ECB40.
B-Electric Heat Components
Overview of the components within the ECB40 electric heat sections.
Unit Components
Detail A
Illustration showing the discharge air sensor and its mounting.
Detail B
Wiring diagram for the 9-pin connector on the air handler control.
Indoor Blower Motor (ECM) (B3)
Motor Start-Up
Steps and procedures for starting up the ECM blower motor.
Indoor Blower Motor Control Troubleshooting (Emerson)
Additional Indoor Blower Motor (B3) Troubleshooting
Further troubleshooting steps for the indoor blower motor and its control module.

Table of Contents

Save PDF