Feature Overview - Panamax M7500-PRO Owner's Manual

Manual
Hide thumbs Also See for M7500-PRO:
Table of Contents

Advertisement

FEATURE OVERVIEW

1. Power Switch
2. Bank Status Indicators:
Pushbutton; activates a
When on, indicates that the
turn-on or turn-off
corresponding bank is on.
sequence for all outlets
when depressed for two
When off, indicates the corre-
seconds.
sponding bank is off.
When flashing, indicates the
bank is in transition, either
turning on or turning off.
BANK 1 ON
BANK 2 ON
BANK 3 ON
POWER FILTRATION AND REGULATION ACTIVE
1. 15A Main Circuit
2. Filtered Regulated
Breaker:
Outlets (BANKS 1 & 2):
Opens in the
event that equipment
Four, Balanced Double L fil-
plugged into the MAX
tered outlets for low current
7500 draws too much
analog audio components
current. When white is
such as pre-amplifiers,
visible, the breaker has
receivers, VCR's and tape
opened. Reduce the
decks.
load and push to reset.
15 AMP CIRCUIT BREAKER
BANK 1 ALWAYS ON
GROUND
LUG
REGULATED
HD CABLE
HD SAT
MAIN POWER 120VAC/15A
12 AMP MAX
9. Ground Lug:
8. IEC Main Power
common grounding point for
Receptacle:
equipment with separate
Detachable power cord
ground leads
connects to this recep-
tacle.
3. Ground Isolation:
Controls the ground connec-
tion of banks 3 and 4.
When active these banks
have Balanced Power with an
isolated ground connection.
When not active these banks
have Balance Power with a
common ground reference.
M7500-PRO
BANK 4 ON
BANK 5
BANK 5
HC 1 ON
HC 2 ON
GROUND
HIGH CURRENT
ISOLATION
ACTIVE
4. Brightness Control/Meter Select:
When in the full/locked left position, auto brightness is engaged, and the front panel display will dim with the ambient light level.
Rotating the knob to the right will increase the display brightness, and left will decrease the display brightness.
Pressing this control will toggle the display of the second meter from "Volts Out" to "Amps In".
3. Isolated (Switched)
Outlets (BANKS 3 & 4):
Four outlets provide complete
isolation for digital source
components such as DVD
players or display devices like
plasma TVs or DLP
projectors. These outlets are
completely isolated from the
rest of the system.
BANK 2 SWITCHED
BANK 3 SWITCHED
TEST
RESET
DVR &
DIGITAL
RADIO
TEST
RESET
6 AMP MAX
10. DC Trigger Input:
Provides a
3.5mm (1/8") Mini-Plug jack.
Connect to a remote trigger
device that uses a DC voltage
signal to initiate a startup/shut-
down sequence.
11. DC Trigger Output:
(1/8") Mini-Plug jack. The M7500-Pro
generates its own 12VDC trigger to
control another device.
5. Voltmeter:
Backlit analog meter displays the incoming voltage between
90-140 VAC.
Integrated "Unsafe Voltage" indicator will flash after sensing
an unsafe voltage and disconnecting all outlets.
Integrated "Out of Regulation" indicator will flash whenever
the regulated output voltage is out of spec.
BRIGHTNESS
AUTO
PRESS:
METER SELECT
4. High Current Outlet
5. Isolated Outlets
Bank (BANK 5):
Two
Circuit Breaker:
delayed outlets designed
Opens in the event that
for high current compo-
equipment connected to
nents such as amplifiers
the Isolation Transformer
and powered subwoofers.
Outlets exceeds 6 Amps
The current available to
current draw. When white
connected equipment is
is visible, the breaker has
not limited by the noise
opened. Reduce the load
filtration components.
and push to reset.
BANK 4 SWITCHED
BANK 5 HIGH CURRENT
CIRCUIT BREAKER
BANKS 3 AND 4
TEST
RESET
HC 1
SWITCHED
SUB
RECEIVER
AMP
TEST
RESET
HC 2
SWITCHED
INPUT
3-24VDC
6 AMP MAX
15 AMP MAX
12. Outlet Delay Switches:
3.5mm
Two-position slide switches. Allows
for the user to configure each bank
for delayed turn-on/turn-off or
always-on operation.
4
6. Combination Meter:
Displays the regulated output voltage,
90-140 VAC in one mode. Displays
the Input Current draw, 1-15 Amps,
in the alternate mode.
6. Universal Cable and
Satellite TV Coax Jacks
Four pairs of F-Connectors opti-
mized for Satellite TV, Cable TV,
Antenna or Cable Modem signal
line protection. Bi-directional
UNIVERSAL
2
3
1
COAX
PROTECTION
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ON
DELAY
ON
DELAY
ON
DELAY
ON
DELAY
BANK 2
BANK 3
BANK 4
5 HC 1
TRIGGER
LAN
LAN
PHONE
PHONE LINE
TO EQUIP
TO EQUIP 1
LINE IN
LINE IN
OUTPUT
12V/400mA
13. LAN:
14. Telephone Jacks:
In/Out
1 In & 2 Out connections
connections
for telephone line or
for Ethernet.
pay-per-view line
protection.
15. Lamp
Receptacle:
The convenience lamp
included with the M7500-
Pro is to illuminate the
rear panels of other com-
ponents during setup.
7. Ambient
Light Sensor
Home Theater Power Management
8: Convenience Outlet:
Provides a quick convenient way to
plug in components such as cam-
corders and video game systems.
7. Settings Option:
Two-
position slide switch. Switch
settings selects the use of the
five switches to configure the
outlets for delayed or always-
on operation. Custom settings
selects the stored configuration
in non-volatile memory for the
outlets trigger source and
delays. See Page 10-15 for
details.
4
UNIVERSAL
COAX
PROTECTION
SWITCH
SETTINGS
ALWAYS
ON
DELAY
5 HC 2
CUSTOM
SETTINGS
PHONE LINE
TO EQUIP 2
USB LIGHT
5VDC/100mA
16. Communications
Interface:
RS232
interface for custom con-
figuration and/or home
automation control.
Contact Panamax for
availability of alternate
TCP/IP interface.
USB jack.