Panamax M7500-PRO Owner's Manual
Hide thumbs Also See for M7500-PRO:

Advertisement

Quick Links

MAX
7500-PRO
®
HOME THEATER POWER MANAGEMENT
Owner's Manual
MODEL: M7500-PRO
Thank you for purchasing this MAX
Home Theater Power Management! You now own
one of the finest line conditioning, regulating and
power protection products on the market today.
Over 30 years of power protection experience and
more than 15 years of Audio/Video noise filtra-
tion experience were utilized during the develop-
ment of this model.
7500-PRO
The MAX
®
neered to enhance the performance and life
expectancy of high-end Audio/Video entertain-
ment gear. The combination of our sophisticated
power conditioning and the world's finest power
protection has resulted in an Audio/Video power
center that meets the power quality needs for each
piece of equipment in your entertainment system.
1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com
7500-PRO has been specifically engi-
®
This is truly a Firewall for Noise™! With power
this clean, your audio/video or home theater sys-
tem will finally be able to perform up to its full
capabilities. Performance alone makes this a
world-class product but we didn't stop there; its
styling complements and completes even the
most sophisticated Audio/Video showcase.
INS7500_EN REV. D
9/07

Advertisement

Table of Contents
loading

Summary of Contents for Panamax M7500-PRO

  • Page 1 Audio/Video showcase. ment of this model. piece of equipment in your entertainment system. INS7500_EN REV. D 9/07 1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com...
  • Page 2: Table Of Contents

    2 - Rack ears w/ screws for rack mounting option If the M7500-PRO is installed in a rack, this “blank” must be installed directly below the M7500-PRO to ensure proper ventilation. Please verify that you have received all these items. If not, contact Panamax.
  • Page 3: Important Safety Instructions

    6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. If the M7500-PRO is installed in a rack, this “blank” must be installed directly below the M7500-PRO to ensure proper ventilation.
  • Page 4: Introduction

    3 and 4 is connected to enhance your overall entertainment experi- Thank you for choosing Panamax for your ground, as is the center tap of the isolation ence, including: power quality needs.
  • Page 5: Connection Diagram

    CONNECTION DIAGRAM STEP 1 Typical AC Power, RS232 and 12V Trigger Connections AMPLIFIER HOME AUTOMATION CONTROL AUDIO VIDEO RECEIVER BANK 1 ALWAYS ON BANK 2 SWITCHED BANK 3 SWITCHED BANK 4 SWITCHED BANK 5 HIGH CURRENT 15 AMP CIRCUIT BREAKER UNIVERSAL UNIVERSAL COAX...
  • Page 6: Feature Overview

    11. DC Trigger Output: 12. Outlet Delay Switches: 3.5mm Receptacle: USB jack. (1/8”) Mini-Plug jack. The M7500-Pro Two-position slide switches. Allows The convenience lamp generates its own 12VDC trigger to for the user to configure each bank included with the M7500- control another device.
  • Page 7: Feature Details

    FEATURE DETAILS Convenience Outlet: Power Switch and LED Indicator: Momentary A single outlet on the front panel of the Max 7500- M7500-PRO Pushbutton (non-latching); activates a turn-on or BRIGHTNE Pro provides an easy-to-reach power source for elec- BANK 1 ON...
  • Page 8: Regulated Outlet Banks 1 And 2

    FEATURE DETAILS (continued) Banks 1 and 2 Regulated Outlets: In the Custom Settings mode all of the outlet 15 AMP CIRCUIT BREAKER BANK 1 ALWAYS ON BANK 2 SWITCHED BANK 3 SWITCHED BANK 4 SWITCHED BANK 5 HIGH CURRENT Two individually switched banks are fed through delays as well as the trigger sources for each individ- separate “Balanced Double L”...
  • Page 9: Telephone Line Protection

    FEATURE DETAILS (continued) Telephone Protection: AC Surge Protection: This unit provides protection to one telephone Line When the MAX 7500-Pro is subjected to a high volt- GH CURRENT In (RJ-11), and incorporates a built-in splitter to age surge, its voltage output is limited to a safe level UNIVERSAL UNIVERSAL COAX...
  • Page 10: Technical Specifications

    TECHNICAL SPECIFICATIONS DC TRIGGER OUTPUT GENERAL Dimensions....17” W x 12.75” D x 3.5” H, (4.1” H including feet) Voltage......................<12V Weight.....................36 lbs. Current.....................<400 mA Short-circuit protection..................Yes AC CIRCUIT PROTECTION AND FILTRATION Delay on output..................10 seconds AC POWER: Line Voltage..................120V, 60Hz LAN CIRCUIT Regulation Range..................100V-135V Regulated Output..................120V ±...
  • Page 11 MAX PRO-SERIES Communication/Configuration Specifications 1. OVERVIEW The M7500-PRO has a RS232 interface that allows it to communicate with a wide variety of equipment as well as enable custom DB9 Pinout Diagram operating configurations to be programmed into the unit. 5 4 3 2 1 The purpose of this document is to outline the command set used to communicate with the M7500-PRO.
  • Page 12 MAX PRO-SERIES Communication/Configuration Specifications (continued) Command String Action Response !SET_BRIGHT x<CR> Sets the voltmeter, ammeter and LED If x is valid, $BRIGHTNESS = x<CR> x = {10 -100} brightness to x% If x is invalid, $INVALID_PARAMETER<CR> Example: !SETBRIGHT 75<CR> (sets meter brightness to 75%) !SET_TRIGGER bank triggersource<CR>...
  • Page 13 MAX PRO-SERIES Communication/Configuration Specifications (continued) Command String Action Response !SET_FEEDBACK mode<CR> Sets the feedback to ON (unsolicited) or OFF If mode = ON, $FEEDBACK = ON<CR> (polled). When ON, a message will be sent to mode = { ON, OFF } the controller every time the status of an input If mode = OFF, $FEEDBACK = OFF<CR>...
  • Page 14: Rs-232 Command Specification

    MAX PRO-SERIES Communication/Configuration Specifications (continued) QUERIES Query Description Response ?ID<CR> Request that the unit identify itself. $PANAMAX<CR> $MAX 74/7500-PRO<CR> $FIRMWARE revision<CR> ?TRIGSTAT<CR> Request the on/off status of the front panel if front panel button is ON, $BUTTON = ON<CR> button and input trigger.
  • Page 15 MAX PRO-SERIES Communication/Configuration Specifications (continued) QUERIES (continued) Query Description Response Request a list of all configurable ?LIST_CONFIG<CR> $TRIGGER FOR 1 = triggersource<CR> parameters and current settings. $TRIGGER FOR 2 = triggersource<CR> $TRIGGER FOR 3 =triggersource<CR> $TRIGGER FOR 4 = triggersource<CR> $TRIGGER FOR HC1 = triggersource<CR>...
  • Page 16: Troubleshooting

    High formers, may react unfavorably to this distortion, Current Outlet Bank. Panamax, Inc. 1690 Corporate Circle, Petaluma, CA 94954 Toll Free: (800)472-5555 • Tel: (707) 283-5900 • Fax: (707) 283-590 • www.panamax.com © 2007 Panamax, Inc INS7500_EN Rev. D 9/07...
  • Page 17: Warranties

    Panamax Power Conditioner Limited Connected Equipment Protection Warranty Valid only in the United States and Canada. It is the policy of Panamax that it will, at its 3. NOTIFICATION: You must notify Panamax Panamax reserves the right to inspect the Panamax.