Panamax M5510-PRO Owner's Manual
Hide thumbs Also See for M5510-PRO:

Advertisement

Quick Links

MAX
5510 PRO ACRegenerator
®
Owner's Manual
MODEL M5510-PRO
1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com

Advertisement

Table of Contents
loading

Summary of Contents for Panamax M5510-PRO

  • Page 1 5510 PRO ACRegenerator ™ ® Owner’s Manual MODEL M5510-PRO 1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com...
  • Page 2 PANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax. ACRegenerator, Firewall for Noise, SurgeGate Plus, Protect or Disconnect and SignalPerfect are trademarks of PANAMAX. SIDACtor is a registered US trademark of Teccor Electronics, Inc. TiVo is a trademark of TiVo, Inc.
  • Page 3: Table Of Contents

    1 - IEC 320, 120V/15A 3 - Coax Cables for detachable power cord Satellite TV, Cable TV and/or Antennas Please verify that you have received all these items. If not, contact Panamax. USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901...
  • Page 4: Introduction

    (with 2-blade power plugs) that are plugged into ers that utilize coils (inductors) in series with the Thank you for choosing Panamax for your power these outlets are also isolated, eliminating ground AC power line can “choke” off this large in-rush quality needs.
  • Page 5: Connection Diagram

    CONNECTION DIAGRAM STEP 1 Typical AC Power, RS232 and 12V Trigger Connections AMPLIFIER HOME AUTOMATION CONTROL CD PLAYER AUDIO VIDEO RECEIVER LINE LEVEL AUDIO / VIDEO CIRCUIT CIRCUIT SATELLITE 1 OUT OUT OUT OUT BREAKER BREAKER LIGHT SATELLITE 2 GROUND PROPERLY HIGH CURRENT ALWAYS ON OUTLETS...
  • Page 6: Feature Overview

    The M5510-Pro can generate its 3-position slide switch. Allows adjustment of the own 12VDC trigger to control Turn-On delay for the 2 Delayed High Current another device. Outlets. Choose between 0 and 10 seconds. 1690 Corporate Circle, Petaluma CA 94954 • www.panamax.com...
  • Page 7: Feature Details

    One of the adjacent being drawn by the connected equipment and the LEDs for Isolated Power and Balanced Power will M5510-Pro. The Ammeter needle will fluctuate as illuminate to indicate the active switch position. music or movie soundtracks call upon the amplifiers 5510 PRO ACRenerator ®...
  • Page 8: Sequential Startup/Shutdown

    FEATURE DETAILS (continued) Sequential Startup/Shutdown: Isolated/Switched Outlet Bank: HIGH CURRENT OUTLETS ISOLATED OUTLETS MAIN BREAKER Complex audio/video systems may be susceptible Four outlets (one bank of four) are fed power through to voltage transients generated internally at start- the heart of the MAX 5510-Pro, the Isolation GROUND up/shutdown if all of the equipment is powered on Transformer.
  • Page 9: Filtered Outlet Banks 1 And 2

    FEATURE DETAILS (continued) Filtered Outlet Banks 1 & 2: DC Triggers: Four outlets (two banks / two outlets per bank) are Input Trigger: This feature provides an ON/OFF fed through separate “Balanced, Double L” noise fil- trigger for the MAX 5510-Pro using a DC voltage ISOLATED OUTLETS BREAKER LINE LEVEL AUDIO / VIDEO ISOLATED OUTLETS...
  • Page 10: Isolation Transformer Circuit Breaker

    UPS to the equipment’s telephone jack or net- CATV N / TELCO work device. Panamax's exclusive SignalPerfect™ Technology provides application specific protection for your Please Note: The protection circuitry will not work satellite and cable TV equipment. The satellite if the phone lines are reversed.
  • Page 11: Surgegate Plus™ Protection

    FEATURE DETAILS (continued) Patented Over/Under Voltage Protection: The MAX 5510-Pro requires line voltage to return to within the safe operating range for 10 seconds before The MAX 5510-Pro constantly monitors the AC line returning to normal operating mode. This is referred voltage for unsafe voltage conditions such as pro- to as "Over/Under Voltage Recovery".
  • Page 12: Rs-232 Command Specification

    1. OVERVIEW DB9 Pinout Diagram The Panamax Pro-Series product family has a RS232 interface that allows it to communicate with a wide variety of equipment. 5 4 3 2 1 The purpose of this document is to outline the command set used to communicate with the Pro-Series (PS) products.
  • Page 13: Isolated Vs. Balanced Power

    ISOLATED vs. BALANCED POWER Power Modes in the MAX 5510 Balanced Power ® Single-phase grounded-neutral power Supply Equipment The standard method of residential power delivery in the U.S. LINE LINE The neutral, or "grounded" conductor, is bonded to the earth, or "grounding"...
  • Page 14: Troubleshooting

    If the unsafe voltage LED is The provided coax or telephone jumper These four outlets are designed specifically for OFF and the light is still not on, call Panamax cables are not long enough to reach my low-current, digital source components. Check Customer Service for help.
  • Page 15 PANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax. ACRegenerator and SignalPerfect are trademarks of PANAMAX. SIDACtor is a registered US trademark of Teccor Electronics, Inc. TiVo is a trademark of TiVo, Inc. USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901...
  • Page 16 1690 Corporate Circle, Petaluma, CA 94954 Tel: (707) 283-5900 Fax:: (707) 283-5901 Email: sales@panamax.com Web: www.panamax.com © 2004 Panamax INS0762 Rev A 12/04...

This manual is also suitable for:

Max 5510 pro acregenerator

Table of Contents