M5300-Pm Front Panel Features; M5300-Pm Back Panel Connection Features - Panamax M5300-PM Manual

Manual
Hide thumbs Also See for M5300-PM:
Table of Contents

Advertisement

Available languages

Available languages

M5300-PM Front Panel Features

Power Button
Power Indicators
Press and hold for
Indicates the status of the
one second to turn
rear panel outlets. The LED
Bank 3, 4, and 5 out-
outlet bank icon will be lit
lets ON or OFF.
when the corresponding out-
lets are turned ON. They will
flash during the startup and
shutdown process.
BANK 1
BANK 2
BANK 3
BANK 4
LINEAR
LINEAR
LINEAR
LINEAR
FILTER
FILTER
FILTER
FILTER

M5300-PM Back Panel Connection Features

Outlet Bank 5
Circuit Breaker
Two switched, high-current outlets controlled by
Automatically opens
the front panel Power Button or the DC Trigger
when the current load
input. Bank 5 has a 5 second turn on delay and
is greater than 15
turns off immediately upon shutdown. The High
Amps. Push to reset.
Current outlets provide power from a low imped-
ance noise filtration circuit that does not limit the
current to your equipment. Its output is noise
isolated from all other outlet banks
15 AMP CIRCUIT BREAKER
HIGH CURRENT
GROUND
LUG
SWITCHED DELAYED
MAIN POWER 120 VAC/15A
BANK 5
Main Power
Ground Lug
Must be plugged into a properly
Provides a common
wired & grounded 3-wire outlet.
grounding point for
equipment with sep-
arate ground leads.
2
Wiring OK LED
Meter/Front Panel LED
Normally On. Indicates
Dimmer
that the wall outlet is
Pushbutton control for
properly grounded and
meter and front panel
Line/Neutral polarity is
LED brightness. Cycles
correct.
between four bright-
ness settings.
BANK 5
HIGH
WIRING
CURRENT
OK
METER LIGHTS
Digital Voltmeter
Digital LED voltmeter indicates the incoming line voltage. If line
voltage drops below 90VAC, or if the line voltage exceeds 142VAC,
the display will turn off and the "unsafe voltage" indicator will flash
indicating an unsafe voltage condition.
Outlet Banks 3 and 4
Two switched outlets with linear filtration tech-
nology (LiFT) controlled by the front panel
Power Button or the DC Trigger input. Banks 3
& 4 will turn on immediately and turn off after a
10 second delay. LiFT EMI/RFI noise filtration is
provided by a two-stage balanced Pi filter which
also provides noise isolation from all other out-
let banks.
LINEAR FILTER
LINEAR FILTER
SWITCHED
SWITCHED
BANK 4
BANK 3
Bank 1 and 2
Indicator Light
Normally ON, is lit
when there is power
present on Bank 1
and 2 receptacles.
Unsafe Voltage Indicator
Located in the Voltmeter and
is normally off. Flashes red
to indicate that the incoming
line voltage is unsafe and the
unit has disconnected the
power to protect your equip-
ment.
VOLTS
AMPS
Digital Ammeter
Shows the actual current draw (0-15A) of the connected
components system, giving a visual reference as to how
the system is functioning under a variety of conditions.
Outlet Banks 1 and 2
Two always-on outlets with linear filtration tech-
nology (LiFT). Power will only be turned off
under a fault condition (See specifications for
over-voltage and under-voltage thresholds). LiFT
EMI/RFI noise filtration is provided to Banks 1 &
2 by a two-stage balanced Pi filter which also
provides noise isolation from all other outlet
banks.
LINEAR FILTER
LINEAR FILTER
ALWAYS ON
ALWAYS ON
BANK 2
BANK 1
Voltage Sense
Voltage Sense
Trigger Output
Trigger Input
3.5mm (1/8") Mini-Plug
3.5mm (1/8") Mini-Plug
jack. Connecting a trig-
jack. Connect to a remote
ger wire to the Voltage
trigger device that uses a
Sense Output jack will
DC output to trigger a start-
allow the input signal to
up/shutdown sequence.
pass through the M5300-
This bypasses the front
PM to control the start-
panel power switch.
up/shutdown of an addi-
tional device.
USB Charging Port
Convenience
For charging portable
LAN Port
electronic devices
Offers an Ethernet
while protecting them
pass-thru connection
from unsafe voltages.
between the front and
rear panel.
USB 5V.
UNIVERSAL COAX PROTECTION
1
2
BANK
1 & 2
VOLTAGE
ON
LAN 1
LAN 2
SENSE TRIGGER
LINE IN
LINE IN
OUTPUT
INPUT
(3-24 VDC)
LAN Jacks
Protection circuits for 10/100
baseT Ethernet lines. For the LAN
2 protected jacks, the incoming
LAN line MUST be plugged into the
LINE jack and the patch cord to the
equipment MUST be plugged into
the EQUIP jack. For the LAN 1 pro-
tected jacks the incoming LAN line
must be plugged into the LINE jack
and the equipment must be
plugged into the jack on the front
panel. 8 wire protection, 52V
clamping.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article
provides specific guidelines for proper grounding. It specifies that the cable ground
shall be connected to the grounding system of the building and as close to the point
of entry as practical.
Gaming Outlet
Convenient front
panel outlet provides
surge protection for
gaming systems,
digital cameras,
camcorders, and
other devices.
M5300-PM
Universal TV Coaxial Jacks
3 pairs of bidirectional pro-
tection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3
PHONE
EQUIP.
LINE IN
EQUIP.
Phone Jacks
Protection circuits for standard
telephone or pay-per- view
lines. Phone circuit is auto-
resetting. Incoming phone
cord MUST be plugged into
the LINE jack. Patch cords to
the equipment (satellite receiv-
er, digital video recorder, tele-
phone, etc.) MUST be plugged
into the EQUIP jacks.