M5100-Pm Front Panel Features; M5100-Pm Back Panel Connection Features - Panamax M5100-PM Manual

Manual
Hide thumbs Also See for M5100-PM:
Table of Contents

Advertisement

Available languages

Available languages

M5100-PM Front Panel Features

Power Button
Power LEDs
Press and hold for
Indicates the status of the
one second to turn
rear panel outlets. The LED
Bank 2 and Bank 3
outlet bank icon will be lit
outlets ON or OFF.
when the corresponding out-
lets are turned ON. They will
flash during the startup and
shutdown process.
BANK 1
LINEAR
FILTER

M5100-PM Back Panel Connection Features

Circuit Breaker
Outlet Bank 3
Two switched, high-current outlets controlled by the
Automatically opens
when the current load
front panel Power Button or the DC Trigger input.
is greater than 15
Bank 3 has a 5 second turn on delay and turns off
immediately. The High Current outlet provides power
Amps. Push to reset.
from a low impedance noise filtration circuit that does
not limit the current to your equipment. Its output is
noise isolated from all other outlet banks
HIGH CURRENT
15 AMP
CIRCUIT
BREAKER
GROUND
SWITCHED
LUG
DELAYED
MAIN POWER
BANK 3
120 VAC/15A
Main Power
Ground Lug
Must be plugged into a properly
Provides a common grounding
wired & grounded 3-wire outlet.
point for equipment with separate
ground leads.
2
Wiring OK LED
Normally On. Indicates
that the wall outlet is
properly grounded and
Line/Neutral polarity is
correct.
BANK 2
BANK 3
LINEAR
HIGH
WIRING
OK
FILTER
CURRENT
Digital Voltmeter
Digital LED voltmeter indicates the incoming line voltage. If line voltage drops below 90VAC, or if the
line voltage exceeds 142VAC, the display will turn off and the "unsafe voltage" indicator will flash
indicating an unsafe voltage condition.
Outlet Bank 2
Four switched outlets with linear filtration technolo-
gy (LiFT) controlled by the front panel Power
Button or the DC Trigger input. Bank 2 will turn on
immediately and turn off after 10 seconds. LiFT
EMI/RFI noise filtration is provided by a two-stage
balanced Pi filter which also provides noise isola-
tion from Outlet Banks 1 and 3.
LINEAR FILTRATION - SWITCHED
BANK 3
Meter/Front Panel LED
Unsafe Voltage Indicator
Dimmer
Located in the Voltmeter and
Pushbutton control for
is normally off. Flashes red
meter and front panel
to indicate that the incoming
LED brightness. Cycles
line voltage is unsafe and the
between four bright-
unit has disconnected the
ness settings.
power to protect your equip-
ment.
VOLTS
LINEAR FILTRATION - ALWAYS ON
BANK 1
Bank 1 Indicator Light
Voltage Sense Trigger
Normally ON, is lit
Input
when there is power
3.5mm (1/8") mono
present on the Bank 1
mini-plug. Connect to
receptacles.
a remote trigger device
that uses a DC output
to trigger a startup/shut-
down sequence.
Convenience LAN
USB Charging Port
Port
For charging
Offers a bi-direction-
portable electronic
devices while pro-
al Ethernet pass-thru
connection between
tecting them from
the front and rear
unsafe voltages. USB
panel.
5V/5x 100 mA or
500 mA
Outlet Bank 1
Four always-on outlets with linear filtration technolo-
gy (LiFT). Power will only be turned off under a fault
condition. (See specifications for over-voltage and
under-voltage thresholds) Power is cleaned by a
two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.
UNIVERSAL COAX PROTECTION
1
2
BANK 1
ON
LAN 1
LINE IN
LINE IN
IN
12V
TRIGGER
LAN Jacks
Protection circuits for 10/100
baseT Ethernet lines. Incoming
LAN line MUST be plugged into
the LINE jack. Patch cord to the
equipment MUST be plugged into
the EQUIP jacks. 1 LAN jack goes
to the front panel output jack. 8
wire protection, 50V clamping.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article
provides specific guidelines for proper grounding. It specifies that the cable ground
shall be connected to the grounding system of the building and as close to the point
of entry as practical.
Gaming Outlet
Convenient front
panel outlet provides
surge protection for
gaming systems, digi-
tal cameras, cam-
corders, and other
devices.
M5100-PM
Universal TV Coaxial Jacks
3 pairs of bidirectional pro-
tection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3
PHONE
LAN 2
EQUIP.
LINE IN
EQUIP.
Phone Jacks
Protection circuits for standard
telephone or pay-per- view
lines. Phone circuit is auto-
resetting. Incoming phone
cord MUST be plugged into
the LINE jack. Patch cords to
the equipment (satellite receiv-
er, digital video recorder, tele-
phone, etc.) MUST be plugged
into the EQUIP jacks.