23. H.POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : H.POSITION Gain Flag
DATA02 : H.POSITION Gain
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: H.POSITION Gain Flag
24. V-HEIGHT Gain Data
Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : V-HEIGHT Gain Flag
DATA02 : V-HEIGHT Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01
DATA00: USER PICTURE Gain Flag
DATA01: V-HEIGHT Gain Flag
03H
02H
80H : -128
:
FFH : -01
00H : 0
01H : +01
:
7FH : +127
DATA01 CKS
03H
02H
03H
07H
00H : 0
:
40H : +64
03H
24
CKS
07H