61.POWER DELAY ON
Function
External control apparatus attaches a time lag to two or more plasma
monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00:
*: This command is premised on two or more plasma monitor system
composition being multi-systems. In command issue of master
the value of DATA00 is 01H (1 second). This command does not have ACK for
one-way traffic.
*1: "Master" means the 1st set of PDP at the time of cable connection at
the time of AUTO ID execution.
62.GAMMA GAIN Data
Function
External control apparatus changes Gamma of a plasma monitor.
Transmission Data
DFH 80H 60H 13H 02H DATA00 DATA01 CKS
DATA00: GAMMA FLAG
DATA01: GAMMA
ACK
7FH 60H 80H 13H 01H DATA00 CKS
DATA00: GAMMA FLAG
00H-FFH: Delay time (second)
01H : Gamma change
00H :1
01H : Gamma change
54
OSD operation,
1
01H :2
02H :3
03H :4