Arrays; Configuring Arrays From Physical Drives; Raid 0 (Data Striping) (S1-S4) Of Data Blocks (B1-B12) - HP X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server User Manual

Hp storageworks x1000 and x3000 network storage system user guide (5697-0185, november 2009)
Hide thumbs Also See for X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server:
Table of Contents

Advertisement

Include the appropriate number of physical drives in the arrays to create logical storage elements
of desired sizes.

Arrays

See
Figure
16. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or more logical units (L1) called arrays. When this is
done, the read/write heads of all the constituent physical drives are active simultaneously, dramatically
reducing the overall time required for data transfer.
NOTE:
Depending on the storage system model, array configuration may not be possible or necessary.
Figure 16 Configuring arrays from physical drives
.
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of
data stripes over all the hard drives in an array, as shown in
Figure 17 RAID 0 (data striping) (S1-S4) of data blocks (B1-B12)
.
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the data blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array, the extra capacity
is wasted because it cannot be used by the array.