Systems Insight Display LED combinations

When the internal health LED on the front panel illuminates either amber or red, the server is
experiencing a health event. Combinations of illuminated system LEDs and the internal health LED
indicate system status.
Table 11 Systems Insight Display LEDs and internal health LED combinations
Systems Insight
Display LED and
color
Processor failure,
socket X (amber)
PPM failure, slot X
(amber)
DIMM failure, slot X
(amber)
DIMM failure, all
slots in one bank
(amber)
DIMM failure, all
slots in all banks
(amber)
Online spare
memory (amber)
Online spare
memory (flashing
amber)
Online spare
memory (green)
Mirrored memory
(amber)
Mirrored memory
(flashing (amber)
Mirrored memory
(green)
Internal health LED
Status
color
One or more of the following conditions may exist:
Red
Amber
Processor in socket X is in a pre-failure condition.
One or more of the following conditions may exist:
Red
Red
DIMM in slot X has failed.
Amber
DIMM in slot X is in a pre-failure condition.
One or more DIMMs has failed. Test each bank of DIMMs by
Red
removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
One or more DIMMs has failed. Test each bank of DIMMs by
Red
removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Amber
Bank X failed over to the online spare memory bank.
Red
Invalid online spare memory configuration.
Green
Online spare memory enabled and not failed.
Amber
Bank(s) X failed over to the mirrored memory bank(s).
Red
Invalid mirrored memory configuration.
Green
Mirrored memory enabled and not failed.
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding pro-
cessor is installed.