Using a Text
Editor
Using the Push
Button
A-10 Troubleshooting
Follow the steps below to restore the default settings:
1. Locate and open the CD-ROM server's
a text editor (for example, Windows Notepad).
2. Change the
FactoryDefaults
3. Save the file.
This writes the contents of the file to the CD-ROM server and
will reset the server to factory defaults.
Follow the steps below to restore the default settings:
1. Turn off the CD-ROM server (by removing power).
2. Press and hold the Push button while you power on the
CD-ROM server. Continue to press the Push button until the
Network indicator flashes at regular two second intervals.
3. Release the Push button and wait at least two seconds (one
flash of the Network indicator).
4. Press and hold the Push button again for at least five seconds
until the Network indicator remains constantly on.
The CD-ROM server is now reset to factory default settings and
should automatically restart. If it fails to restart, try power
cycling the CD-ROM server.
parameter from
Push button
(Tower Module)
file using
config.ini
to
no
yes
Push button
(Stand-Alone Module)
.
Need help?
Do you have a question about the J3278B - SureStore CD-ROM Server/Tower 7 NAS Server and is the answer not in the manual?