Cisco N5K-M1600 - Expansion Module - 6 Ports Troubleshooting Manual page 118

Troubleshooting guide
Table of Contents

Advertisement

VSANs
S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k - d o c f e e d b a c k @ c i s c o . c o m .
Communication problem between host and storage devices
The communication problem between host and storage devices is because:
Example:
zoneset name ZoneSet_Host_Storage vsan 100
zone name Zone_Host_Storage vsan 100
* fcid 0x640114 [pwwn 20:00:00:25:b5:00:20:0e] [Host]
Possible Cause
The host or storage port are in the wrong VSAN.
Example:
switch(config)# show fcns database
VSAN 50:
--------------------------------------------------------------------------
FCID
--------------------------------------------------------------------------
0x420000
Solution
Move the storage port to the correct VSAN. (VSAN 100 is the correct VSAN in the example.).
Example:
switch(config)# show flogi database vsan 50
--------------------------------------------------------------------------------
INTERFACE
--------------------------------------------------------------------------------
fc2/2
Total number of flogi = 1.
switch(config)# vsan database
switch(config-vsan-db)# vsan 100 interface fc 2/2
Traffic on fc2/2 may be impacted. Do you want to continue? (y/n) [n] y
switch(config-vsan-db)# show zoneset active vsan 100
zoneset name ZoneSet_Host_Storage vsan 100
zone name Zone_Host_Storage vsan 100
* fcid 0x640114 [pwwn 20:00:00:25:b5:00:20:0e] [Host]
* fcid 0x5a0000 [pwwn 50:0a:09:81:86:78:39:66] [Storage]
VSAN is down between switches
The VSAN is down between switches because:
Cisco Nexus 5000 Series Troubleshooting Guide
5-46
Zones are active.
Both host and storage are logged into the SAN.
The storage port is not logged into the active zone set.
pwwn 50:0a:09:81:86:78:39:66 [Storage]
TYPE
PWWN
N
50:0a:09:81:86:78:39:66 (NetApp)
[Storage]
VSAN
FCID
50
0x420000
VSAN is configured on both switches.
Trunk allow list allows the VSAN.
(VENDOR)
PORT NAME
50:0a:09:81:86:78:39:66 50:0a:09:80:86:78:39:66
[Storage]
Chapter 5
Troubleshooting SAN Switching Issues
FC4-TYPE:FEATURE
scsi-fcp:target
NODE NAME
OL-25300-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents