Single Frequency, Single Beam, Low Power Transducer Connection - Simrad 50-7 - INSTALLATION REV A Installation Manual

50 khz single beam transducer
Table of Contents

Advertisement

Simrad 50-7
Single frequency, single beam, low power
transducer connection
Transducer
cable
Screen
W802-1
Rev.E
36
This is the termination of the transducer cable from a single
frequency, single beam transducer to the transducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently fixed to the transducer.
All transducer cables must be run in steel conduits. Use a flexible
conduit closer to the transceiver.
Low power output is achieved when the GPT is equipped with
a single transmitter board. In most systems, this will result in
a 2 kW output power, but older GPTs may only be capable of
supplying 1 kW.
Junction Box (1:1)
(Optional)
Single frequency, single beam, low power termination
Note
The cable screen must not be connected to the ship's ground
through the junction box.
The cable screen can be connected to the junction box chassis, but
the junction box chassis must not be connected to ship's ground.
GPT Transducer
A
N
socket
B
M
C
L
D
K
E
J
F
H
Connect to plug housing
D
C
305270/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

50-7Ksv-203665

Table of Contents