Facing the E04 Code with Ease
Why do machines have low-temperature protection?
In order to extend the life of the machine and to maintain its powerful cutting
performance.
Why don't other brands have this?
Because we want you to get the best value for your money with the lowest
spend, and we care and value the longevity of our machines.
We are constantly innovating and upgrading.
What happens when low temperature protection occurs
① In a low temperature working environment
②Press the torch gun switch.
③Digital display is E04
How to cancel the low temperature protection ?
Step
1, Open the cover,
at mark ①,
loosen the screws with a screwdriver,
remove the small board connecting wires, and move the small board out of
position.

Advertisement

loading
Need help?

Need help?

Do you have a question about the RBC6000D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reboot RBC6000D

  • Page 1 Facing the E04 Code with Ease Why do machines have low-temperature protection? In order to extend the life of the machine and to maintain its powerful cutting performance. Why don't other brands have this? Because we want you to get the best value for your money with the lowest spend, and we care and value the longevity of our machines.
  • Page 2 Step 2, loosen the screws at mark ② and remove the wire fasteners. Step 3, Remove the cable at mark ③ Then there are only two steps : 1、Replace the new cable (Feel free to contact us to send it to you) 2、Restore the machine, ready to work.