Troubleshooting Tips - WS-9160U-ITv3 Wireless Digital Thermometer
"NO" for OUTDOOR? lost connection, Hold SENSOR button on display for 2 seconds to
begin searching. (station searches for 3 minutes every hour to reconnect)
Bar icons will flash while searching, icons will be constant (not flashing) when connected.
WHY DOES TEMP Come and Go? Radio Frequency (RF) can temporarily go out in high
humidity or certain conditions. Please wait 2-4 hours for it to reconnect on its own.
RESISTANCE/DISTANCE (walls, windows, metal) reduces range and could cause
interference -Proper distance (up to 330ft/100m without obstructions)
IF NO CHANGE after 30 minutes:
1. Bring sensor 10 ft from station. (recommended batteries with expiration date 6 years in
advance of current year for best performance. TIP: Avoid rechargeable or lithium brands in
display
2. After 15 minutes, move sensor to next room (1 wall separation) from station for 1 hour.
3. If no connection loss in 1 hour, move sensor just outside. After another hour, continue
moving sensor back to original location. Also below proper mounting of the sensor
Sensor Mounting
• Place your thermo-hygro sensor at least 6 feet off the ground.
• For accurate temperature readings your sensor needs to be shaded from the sun
and in a well-ventilated area. Trapped moisture will cause inaccurate readings.
• Mount your sensor vertically to allow moisture to drain out the bottom.
• Preferred location is on a north facing wall under an eave or deck rail.
• Avoid placing near a metal roof that will cause it to read high on sunny days.
• Avoid other sources of heat such as soffit vents, and window or door frames.
• For accurate humidity readings, avoid placement near vegetation and lakes or other
bodies of water when possible.
• Maximum transmission distance from your thermos-hygro sensor to your station, in
open air is 330 feet (100 meters).
• Insert the mounting screw through the front of the transmitter and into the wall.
Tighten the screw to snug (do not over tighten).