Super-Thin-Shipping-Scale
Important:
1. Place this scale on a hard, non-vibrate, flat surface for
weighing.
2. Avoid strong electrical or magnetic fields.
3. It can not use in excessive temperature changes area.
4. Cleaning by using a mild detergent.
5. Do not dismantle the unit, This will cause to damage the
scale, as the result not
Cover by the warranty.
Power Requirements:
This scale operate by 4 pcs of AA size batteries or an
adaptor(adaptor included), if the scale Stop for operate over
a month, there needs to take out all the batteries from the
cabin.
Function Keys:
1) ON/OFF: Press this button for turn on or turn off the
scale.
2) MODE: Press this button for changing weighing modes,
kg → lb → oz → lb-oz, and another usage is for Re
calibration scale.
3) TARE: Press this button to zero
4) HOLD: Press this button to keep the weighing value.
5) C/R: press this button to switch the weighting
capacities.
6) PCS: Press this button for pieces counting function.
1) Press "ON/OFF" button for turn on the scale, once the
display to show: 0.00 the scale ready
For use.
2) Press "MODE" button for changing weighing modes:
kg → lb → oz → lb-oz (Re-circle)
3) Press "TARE" button to subtract the weight of vessel or
container, restore the readout To zero.
4) Press "HOLD" button to keep the weight value.
5) Press "C/R: button for changing the scale's weighing
capacities by user options.
6) Turn on the scale by pressing the "ON/OFF" button,
press "PCS" button show: 0 pc. Press "PCS" button again,
display will show: PC 25, place equivalent 25 units
objects on the middle
of weighing platform, such 25 units' shape,weight need to
the same, (but all the objects total weight not over the
weighing capacity), press "PCS" button again, schedule
complete, 25 pcs
weight's memory storage in scale. This
Weighing:
steps same as PC 50, PC 100 operate.
Calibration:
This scale had been calibrated in factory before
shipment, however, from time to time, there is a remarkable
change in temperature or humidity changed, there might by
inaccuracies, in this case, there needs to re-calibrate the
scale again.
Re – Calibration Method:
When the scales is powered off, press the ON/OFF key
until to show: PE xxx, release it and immediately, press both
ON/OFF and MODE keys at the same time until to show: E –
100, Press MODE key again will show: E – 50, E – 25, E –
10, E – 5. Place a Standard calibration weight: 100kg or 50kg
or 25kg or 10kg Or 5kg on the middle of the platform according
to the LED shown digit,(For example: E – 10, place a standard
10 kgs calibration weight), until The LED show: " Good " ,
calibration is over.
Attention: more weight, more accuracy after calibration.
Trouble Shooting:
Display show:
"H" to mean: the scale has exceeded
the weight limited (over loaded)
Display show: "-E" to mean: the batteries power are
too low, it needs to replace the Batteries or Operate by
adaptor.
Technical specifications
Weighing
Model
Mode
Precision
Mode
PCR-
3115
High
Capacity
Mode
Precision
Mode
Precision
PCR-
Capacity
2126
Mode
High
capacity
Mode
Max.capacity & readability
in Different Units
150kg/
5290oz/
330lb/
0.05kg
1oz
300kg/
10582oz/
660lb/
0.1kg
3oz
60kg/
2116oz/
132lb/
0.02kg
0.5oz
0.04lb
120kg/
4266oz/
264lb/
0.05kg
1oz
200kg/
7055oz/
441lb/
0.1kg
3oz
0.1lb
0.2lb
0.1lb
0.2lb
Need help?
Do you have a question about the Livestock Scale 700 and is the answer not in the manual?
Questions and answers