2 - 26 MC3000 User Guide
Note: Typical performance at 73˚ F (23˚ C)
on high quality symbols.
MC3000
in.
0
cm
0
Figure 2-21
MC3000 Imager Decode Ranges
Table 2-9
MC3000 Imager Decode Ranges
Bar Code Density
5.0 mil
7.5 mil
UPC A
20 mil
5 mil
6.5
4.5
PDF417 6.67 mil
5.3
7.7
7.5 mil
3.3
PDF417 10 mil
4.3
UPC A
2.5
PDF417 15 mil
3.8
2.8
5
12.7
Depth of Field
4.5 in
11.43 cm
3.3 in
8.38 cm
2.5 in
6.35 cm
2.8 in
7.11 cm
10.7
11.1
14.2
14.4
20 mil
10
15
25.4
38.1
Ranges
Near
6.5 in
16.51cm
10.7 in
27.18 cm
14.2 in
36.07cm
18.9 in
48.01 cm
in.
cm
6
15.24
5
12.7
4
10.16
3
7.62
2
5.08
1
2.54
0
0
1
2.54
2
5.08
3
7.62
4
10.16
5
12.7
6
15.24
18.9
20
50.8
Far
W
i
d
t
h
o
f
F
i
e
l
d