Listed direct vent millivol listed direct vent millivolt gas-fired wall furnace (23 pages)
Summary of Contents for Napoleon WPV100T5BA-N
Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. Napoleon WPV100T5BA-N Owner's Manual Shop genuine replacement parts for Napoleon WPV100T5BA-N Find Your Napoleon HVAC Parts - Select From 105 Models -------- Manual continues below part list --------...
Page 2
Available Replacement Parts for Napoleon WPV100T5BA-N W357-0016-SER IGNITER, 601 TYP E TB 120V...
AT ANY TIME, SPECIFICATIONS OR DESIGNS WITHOUT NOTICE AND department. WITHOUT INCURRING OBLIGATIONS. Wolf Steel ltd., 24 Napoleon Rd., barrie, oN, l4m 0g8 Canada / 103 miller Drive, Crittenden, kentucky, uSA, 41030 phone (705)721-1212 • Fax (705)722-6031 • www.napoleonheatingandcooling.com • ask@napoleonheatingandcooling.com W415-0919 / D / 03.27.13...
Table of ConTenTs INTRODUCTION SAFETY SYMBOLS AND WARNINGS SAFETy RulES CoDES FURNACE SIzING LOCATION OF UNIT gENERAl guIDElINES oThER CoNSIDERATIoNS INSTAllATIoN IN upFloW, DoWNFloW oR hoRIZoNTAl poSITIoNS AIR CoNDITIoNINg COMBUSTIBLE CLEARANCES DUCTWORK DuCTWoRk STEpS vENTING AND COMBUSTION PIPING ACCEpTAblE mATERIAlS IN CANADA ACCEpTAblE mATERIAlS IN uNITED STATES NON-DIRECT vENT FURNACE INSTALLATIONS USING INDOOR COMBUSTION AIR (ONE PIPE SYSTEM) DETERmININg CombuSTIoN AIR...
15.0 LOW vOLTAGE WIRING 15.1 SINglE STAgE ThERmoSTAT 15.2 TWo STAgE ThERmoSTAT 15.3 ThERmoSTAT loCATIoN 16.0 OPTIONAL ACCESSORIES (FIELD SUPPLIED/INSTALLED) 16.1 ElECTRIC AIR ClEANER 16.2 poWER humIDIFIER 16.3 EmERgENCy hEAT moDE 17.0 STARTUP PROCEDURES 17.1 To START ThE FuRNACE 17.2 To ShuT DoWN ThE FuRNACE 17.3 SEquENCE oF opERATIoN...
2.0 safeTY sYMbols anD WaRnInGs understand and pay particular attention to the words DANgER, WARNINg, and CAuTIoN and the following defined symbols are used throughout this manual to notify the reader of potential hazards of varying risk levels. DANgER INDICATES AN IMMINENTLY HAzARDOUS SITUATION WHICH, IF NOT AvOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.
WARNINg IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERvICE OR MAINTENANCE CAN CAUSE INJURY, PROPERTY DAMAGE OR LOSS OF LIFE. REFER TO THIS MANUAL. INSTALLATION AND SERvICE MUST BE PERFORMED BY A qUALIFIED INSTALLER, SERvICE AGENCY OR THE GAS SUPPLIER. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO qUALIFIED SERvICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS FURNACE.
Page 8
a. Any applicable local codes, by-laws and regulations. b. Canada: current edition of CAN/CSA C22.1, Canadian Electrical Code (part 1). c. united States: current edition of ANSI/NFpA 70, National Electrical Code. Codes and additional information may be obtained from: Canadian Standards Association American gas Association 5060 Spectrum Way 400 North Capitol Street, NW, Suite 450...
Page 9
WARNINg WHEN THIS FURNACE IS INSTALLED IN A RESIDENTIAL GARAGE, IT MUST BE INSTALLED SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18” ABOvE THE FLOOR TO PREvENT THE RISK OF IGNITING FLAMMABLE vAPORS WHICH MAY BE PRESENT IN THE GARAGE. THE FURNACE MUST BE LOCATED OR PROTECTED TO AvOID PHYSICAL DAMAGE BY vEHICLES.
3.0 fURnaCe sIzInG The maximum hourly heat loss for each heated space shall be calculated in accordance with the procedures described in the manuals of the Heating, Refrigeration and Air Conditioning Institute of Canada (HRAI), or by any other method which is suitable for local conditions, provided the results obtained are in substantial agree- ment with, and not less than those obtained using the procedure described in their manuals.
4.0 loCaTIon of UnIT GeneRal GUIDelInes 1. Select a location where the exhaust and combustion air piping can be routed between the furnace and their terminations with a minimum of lengths and fittings. be sure to check that the proposed termination location will meet code requirements with respect to location and minimum clearances.
• “Airplane glue” and similar adhesives and cements • Ammonia, as commonly found in permanent wave solutions used in hair dressing salons • Anti-static fabric softeners used in clothes dryers • Carbon tetrachloride • Chlorinated cleaners and waxes • Chlorine and bromine based swimming pool chemicals •...
NOTE This furnace is approved for installation in attics, alcoves, utility rooms, closets and crawl spaces. If this furnace is to be installed in a utility room, be sure that it is located in such a way as to allow access for servicing or the removal of other appliances installed in the room (hot water heater, for example).
6.0 DUCTWoRK proper airflow is required for the correct operation of this furnace. Insufficient airflow may cause erratic opera- tion, could cause the furnace to cycle on the high temperature limit, and may damage the heat exchanger. Excessive airflow may result in an excessively noisy duct system and may result in undesirable consequences such as creating uncomfortable drafts.
DUCTWoRK sTeps 1. position the furnace to minimize ductwork length and fittings. 2. Cut open a return air inlet. The choices are furnace bottom, either side, or any combination thereof (i.e., two sides or a side and the bottom).In all cases, cut the return air opening the full width of the return air markers on the side panel.
7.0 venTInG anD CoMbUsTIon pIpInG WARNINg READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS SECTION. FAILURE TO PROPERLY vENT OR SUPPLY COMBUSTION AIR TO THIS FURNACE CAN CAUSE CAR- BON MONOxIDE POISONING, OR AN ExPLOSION OR FIRE, RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
8.0 non-DIReCT venT fURnaCe InsTallaTIons UsInG InDooR CoMbUsTIon aIR (one pIpe sYsTeM) The furnace, although designed as a direct vent type appliance, may be installed with the intake vent inside the structure. WARNINg THIS FURNACE AND ANY OTHER FUEL BURNING APPLIANCE MUST BE PROvIDED WITH ENOUGH FRESH AIR FOR PROPER COMBUSTION AND vENTILATION OF THE FLUE GASES.
DeTeRMInInG CoMbUsTIon aIR 8.1.1 Case 1: fURnaCe loCaTeD In a UnConfIneD spaCe unconfined space does not necessarily mean that ventilation will not have to be introduced from the outdoors, particularly in airtight homes. The minimum requirement for unconfined space is a volume of 50 cubic feet for each 1000 btu/hr for all fuel burning appliances located within the unconfined area.
IMPORTANT: IF AN ExhAuST FAN, FIREplACE, CloThES DRyER oR ANy SImIlAR DEVICE IS pRESENT IN ThE INDooR AREA FRom WhICh ThE CombuSTIoN AND VENTIlATIoN AIR WIll bE DRAWN, NEgATIVE pRESSuRE CoulD bE A pRoblEm IF NATuRAl INFIlTRATIoN FRom ThE ouTDooRS DoES NoT mATCh ThE RATE AT WhICh AIR IS ExhAuSTED.
8.1.4 Case 4: fURnaCe loCaTeD In a ConfIneD spaCe, oUTDooR aIR DUCTeD hoRIzonTallY Similar to Case 3, outdoor air for combustion and ventilation may be drawn through horizontal ducting. The free area for each opening is calculated on the basis of a minimum of 1 square inch per 2000 btu/hr input. The following table shows minimum free areas and round pipe sizes when drawing combustion air horizontally from the outdoors for the furnace only.
9.0 venTInG GUIDelInes CAuTIoN FAIluRE To FolloW All VENTINg guIDElINES mAy RESulT IN ERRATIC FuRNACE opERATIoN, FREEZE-up oF ThE ExhAuST AIR pIpINg, oR SooTINg oF ThE FuRNACE. WARNINg READ AND FOLLOW ALL INSTRUCTIONS IN THIS SECTION. FAILURE TO PROPERLY vENT THIS FURNACE CAN CAUSE CARBON MONOxIDE POISONING OR AN ExPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Take the building orientation and the presence of FIGURE 8 - STANDARD (STRAIGHT) HORIzONTAL other buildings or other nearby structures into consid- vENT DETAIL eration when planning the venting system location. RECOMMENDED Certain external structures could create air turbulence *3” around the vent termination leading to downdrafts and MIN.
FIGURE 10 - vERTICAL vENTING FIGURE 9 - PERISCOPED vENT DETAIL *3” MIN. ROOF TERMINATION EXHAUST 12” MIN. 18” MIN. EXHAUST 12” MIN. INTAKE GRADE *18” MIN. FOR COLD CLIMATES (SUSTAINED 0°F (-17°C) FOR 24 OR MORE CONSECUTIVE HOURS CAuTIoN moISTuRE IN ThE FluE gASES CoNDENSES AS IT lEAVES ThE TERmINAl.
• locate the vent terminal 3 feet above any forced air inlet located within 10 feet. Any fresh air or make-up air inlet, such as for a dryer or furnace area is considered a forced air inlet. The vent terminal should be located no fewer than 6 feet from an inside corner formed by two exterior walls; a 10 foot distance is recommended.
10.0 TeRMInaTIons 10.1 CoMbUsTIon aIR HORIzONTAL - The combustion air termination is made up of a FIGURE 11 - STANDARD vERTICAL medium or long sweep 90° elbow pointing downward to prevent vENTING DETAIL rain from readily entering the combustion air intake piping. If the required clearance to grade cannot be obtained with the “straight through”...
Avoid locating the termination too close to shrubs and other vegetation. The condensate may stunt or kill them. Caulk all cracks, seams or joints within a 6 foot radius of the termination. Do not terminate under a deck unless there is adequate clearance to prevent damage from the flue gases. A termination may be located at the end of a patio deck.
Page 27
FIGURE 14A - DIRECT vENT TERMINAL CLEARANCES W415-0919 / D / 03.27.13...
11.0 RoUTInG opTIons This furnace can be installed in any of four positions. Figures 22-25 on the following pages show the four posi- tions. The installer must consider the following services: gas pipe, electrical power, drain trap, intake and exhaust vents.
Affix the condensate trap assembly to the interior of the side panel in the blower compartment for upflow posi- tions; the interior of the side panel in the burner compartment for downflow positions. For horizontal positions affix the condensate trap assembly to the exterior side panels. Three plastic drain hose clamps are provided in the parts bag.
Page 31
FIGURE 27 IMPORTANT: CONNECT ½” TEE FITTING (FIELD SUPPLIED) TO THE OUTLET OF THE CONDENSATE TRAP. WARNINg THERE MUST NOT BE ANY OPENINGS BETWEEN THE BLOWER DIvISION PANEL AND THE COMBUSTION COMPARTMENT. THE BLOWER COMPARTMENT IS UNDER GREATER SUCTION THEN THE COMBUSTION COMPARTMENT AND CAN PULL COMBUSTION AIR FROM THE BURNERS AND CAUSE INCOMPLETE COMBUSTION AND ERRATIC FURNACE OPERATION.
Page 32
FIGURE 22 - UPFLOW vENT AND DRAINING OPTION CONTINUED RIGHT vENT INSTALLATION IMPORTANT: • PRIME CONDENSATE TRAP WITH WATER AND CUT DRAIN HOSES TO PROPER LENGTH. • CUT PRESSURE SWITCH TUBING TO PROPER LENGTH. NOTE upflow Vent Right - condensate trap must be installed on left side.
Page 33
FIGURE 24 - HORIzONTAL RIGHT vENT AND DRAINING OPTION RIGHT vENT INSTALLATION TOP vENT INSTALLATION IMPORTANT: • PRIME CONDENSATE TRAP WITH WATER AND CUT DRAIN HOSES TO PROPER LENGTH. • CUT PRESSURE SWITCH TUBING TO PROPER LENGTH. FIGURE 25 - DOWNFLOW vENT AND DRAINING OPTION RIGHT vENT INSTALLATION LEFT vENT INSTALLATION NOTE...
CAuTIoN ThE TWo INlETS To ThE DRAIN TRAp ARE FoR VENT pIpE AND CoNDENSATE CollECTIoN. ThE VENT pIpE INlET IS SmAllER ThAN ThE CoNDENSATE CollECTIoN INlET. ENSuRE ThAT ThE DRAIN hoSES ARE pRopERly CuT To ThE REquIRED lENgTh CoNNECTED AND SECuRED. 11.4 DRaIn hose InsTallaTIon 1.
NOTE It is recommended that the condensate drain assembly not be cemented to the condensate trap outlet, if removal of the condensate trap is required in the future. Use a piece of the provided 1/2” drain hose if removal of the condensate trap is anticipated. IMPORTANT: IF AN AIR CoNDITIoNINg EVApoRAToR CoIl DRAIN IS To ShARE ThE FuRNACE DRAIN lINE, IT ShoulD bE CoNNECTED WITh A TEE FITTINg DoWNSTREAm FRom ThE...
FIGURE 21 FIGURE 22 If extra security is desired, it is recommended to secure a strip of strapping around the drain. utilize the exist- ing condensate drain screws to secure the strapping. IMPORTANT: IF AN AIR CoNDITIoNINg EVApoRAToR CoIl DRAIN IS To ShARE ThE FuRNACE DRAIN lINE, IT ShoulD bE CoNNECTED WITh A TEE FITTINg DoWNSTREAm FRom ThE TRAp.
12.0 Gas sUpplY anD pIpInG 12.1 Gas sUpplY WARNINg THIS FURNACE IS FACTORY EqUIPPED TO BURN NATURAL GAS ONLY. CONvERSION TO LP GAS REqUIRES A NATURAL GAS TO LP CONvERSION KIT (W370-0018). FAILURE TO USE THE PROPER CONvERSION KIT CAN CAUSE FIRE, ExPLOSION, CARBON MONOxIDE POISONING, PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
IMPORTANT: ALWAYS USE A BACKUP WRENCH TO PREvENT TWISTING OF THE GAS vALvE. ANY STRAINS ON THE GAS vALvE CAN AFFECT POSITIONING OF THE ORIFICES RELATIvE TO THE BURNERS. THIS COULD RESULT IN FAULTY BURNER OPERATION. Install a manual gas shut-off valve and dirt pocket as close to the furnace as possible. Some local codes call for the manual gas shut-off valve to be located between 4 to 5 feet above floor level to prevent tampering by small children.
13.0 ConveRsIons hIgh AlTITuDE: In Canada, this furnace does not need to be converted for high altitude (2000 - 4500 feet). It has been certified to operate at high altitude as manufactured. In the united States, the modifications for high altitude are based on a 4% reduction of input capacity for every 1000 feet above 2000 feet above sea level.
indicate a leak. ShuT oFF gAS AND FIx All lEAkS ImmEDIATEly! 8. Turn gas back on and test inlet pressure boss with leak detector. 9. If working on a natural gas system, contact the gas utility. They may insist on any service regulator adjust- ments being made by their own staff If problems were encountered with obtaining enough pressure on the manifold, first examine the gas piping system to ensure that it is correctly sized.
6. Turn off the gas and electrical supply to the furnace. WARNINg ALL REGULATOR ADJUSTMENTS MUST BE DONE BY A TRAINED, qUALIFIED TECHNI- CIAN. IMPROPER MODIFICATIONS OR ADJUSTMENTS CAN RESULT IN FIRE OR ExPLO- SION CAUSING PROPERTY DAMAGE, SEvERE PERSONAL INJURY OR LOSS OF LIFE. 7.
14.0 eleCTRICal speCIfICaTIons 14.1 eleCTRICal WIRInG anD ConneCTIons before proceeding with the electrical connections, ensure that the available electrical supply is compatible with the voltage, frequency and phase listed on the appliance rating plate. All furnaces are rated 120 vac, 60 hz, 1 Ø. The amperage rating is 15 amps or less. Each furnace requires a dedicated 15 amp over-current device, either a 15 amp circuit breaker or a 15 amp Type D time delay fuse.
FIGURE 36 - INTEGRATED FURNACE IGNITION CONTROL 5A FUSE 24 VAC MOLEX PARK TERMINALS INTERFACE ELECTRONIC AIR CLEANER POWER THERMOSTAT HUMIDIFIER TERMINALS 120 VAC MOLEX FAULT CODE BUTTON 120 VAC NEUTRAL RED STATUS HEAT STAGING CONNECTIONS JUMPER P5 14.2 fURnaCe ConneCTIon The furnace is shipped fully wired except for the connections to the house wiring.
15.0 loW volTaGe WIRInG The thermostat and control wiring should be a minimum of 18 AWg copper. Excessive lengths of wire may result in enough voltage drop to impair the proper functioning of the furnace. For thermostat wires in excess of 25 feet, use 16 AWg;...
16.0 opTIonal aCCessoRIes (fIelD sUpplIeD/ InsTalleD) 16.1 eleCTRIC aIR CleaneR The integrated furnace control has provisions to supply power and control an electronic air cleaner rated at 120vac, 1.0 amp max. 120 volt power will be available at these terminals whenever the circulating fan is operating in the heating, cooling, and continuous fan modes.
17.0 sTaRTUp pRoCeDURes This furnace is equipped with a hSI (hot Surface Ignition) device. Each time that the room thermostat calls for heat, the hSI lights the main burners directly. See the lighting instructions on the furnace. NOTE It is recommended that the drain trap assembly be primed before the initial startup. Refer to the instructions on how to prime the condensate trap on the previous pages in this manual.
The control flashes “8” on the Red lED if lockout is due to too many flame dropouts (1 hour lockout). 17.4 pRoGRaMMable TheRMosTaT (opTIon) The 9600 Series furnace has an optional programmable two stage Napoleon® Elite Thermostat. For instruction on how to operate and program this unit, please refer to the manual and installation instructions provided with the Napoleon®...
18.0 aIR floW For proper furnace operation, air flow over the heat exchanger is of utmost importance. Insufficient airflow ac- celerates metal fatigue and possible failure in the heat exchanger, as well as decrease efficiency. Excessive airflow promotes accelerated corrosion of the heat exchanger. TAblE 1 - RANgE oF TEmpERATuRE RISE IMPORTANT: Furnace models...
TABLE 10C - AIR FLOW ECM x-13 ESp 0.1” to 1.0” w.c. 45000 btu Two Stage 100000 btu Two Stage Tap # Tap # W1/g y (1.5 Ton) y (2 Ton) y (2.5 Ton) W1/g y (3 Ton) y (4 Ton) y (5 Ton) hEAT 1 hEAT 2...
FIGURE 36 - INTEGRATED FURNACE IGNITION CONTROL FIGURE 39 5A FUSE 24 VAC MOLEX PARK TERMINALS INTERFACE ELECTRONIC AIR CLEANER POWER THERMOSTAT HUMIDIFIER TERMINALS 120 VAC MOLEX FAULT CODE BUTTON 120 VAC NEUTRAL RED STATUS HEAT STAGING CONNECTIONS JUMPER P5 18.4 DehUMIDIfICaTIon - eCM 2.3 For situations where humidity control is a problem, a dehumidification feature has been built into the variable speed motor.
19.0 MaInTenanCe anD TRoUbleshooTInG WARNINg DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE FURNACE BEFORE ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN PERSONAL INJURY OR LOSS OF LIFE. CAuTIoN lAbEl All WIRES pRIoR To DISCoNNECTIoN WhEN SERVICINg CoNTRolS. WIRINg ERRoRS CAN CAuSE ImpRopER AND DANgERouS opERATIoN.
19.3 TRoUbleshooTInG floWChaRT SEqUENCE OF OPERATION Troubleshooting Flowchart Apply Power To Furnace Thermostat Calls For Heat Wait For Limit Circuit Air Proving Switches Wait For Air Proving Switch to Close and/or Reset Proved Open & Limit to Open. Flash "3" of Flame Rollout.
19.4 DIaGnosTIC CoDes foR sTaTUs leD STATUS FAULT CONDITION LEDs lED oFF No power to control or control hardware fault detected lED oN Normal operation 1 Flash high limit switch open 2 Flashes pressure switch open with exhauster on 3 Flashes pressure switch closed with exhauster off 4 Flashes lockout due to too many failed ignition attempts (1 hour lockout)
20.0 WIRe DIaGRaM foR TWo sTaGe fURnaCe WITh eCM 2.3 BLACK INDUCER WHITE 120 VAC GAS VALVE WHITE 24 VAC GREY WHITE IGNITOR 24 VAC BLACK FMC -0.15 YELLOW PRESSURE SWITCH YELLOW 24 VAC IND. LOW -0.20 YELLOW PRESSURE SWITCH YELLOW 24 VAC IND.
Page 55
120 VAC BLACK JUNCTION WHITE TO UPPER GREEN HARNESS BLACK WHITE 120 VAC GREEN BLACK 5 PIN MOLEX BLACK POWER FACTOR TO UPPER HARNESS CORRECTOR CHOKE COIL ¾ hp & 1 hp MODELS ONLY 24 VAC TRANSFORMER + 120 VAC - 24 VAC CONTROL HOUSING VIEW FROM...
WaRRanTY Napoleon® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from Napoleon®.
22.0 ReplaCeMenT paRTs lIsT Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INvOICE WILL BE REqUIRED TO HONOUR THE CLAIM.
Page 58
FIGURE 2 - FURNACE COMPONENTS LEGEND 1. Combustion Air Intake Fitting 11. burner Assembly 2. Flame Roll-out Switch (2) 12. hot Surface Igniter (HSI) - located underneath 3. Flame Sensor - located underneath 13. Two Speed Exhauster 4. Two Stage gas Valve 14.
Need help?
Do you have a question about the WPV100T5BA-N and is the answer not in the manual?
Questions and answers