MSI CD271-S3066 User Manual
MSI CD271-S3066 User Manual

MSI CD271-S3066 User Manual

Advertisement

Quick Links

CD271-S3066
S3066X271RAU24
MS-S376
Server System
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CD271-S3066 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MSI CD271-S3066

  • Page 1 CD271-S3066 S3066X271RAU24 MS-S376 Server System User Guide...
  • Page 2: Table Of Contents

    Contents Regulatory Notices ....................4 System Specifications .....................9 System Overview ....................11 System LED Indicators ...................14 Block Diagram ......................15 System Storage Topology ..................16 Motherboard Overview ..................17 MGT1 DC-SCM Module ...................18 Specifications ......................18 Overview of Components ..................19 Rear I/O Panel ......................20 System LED Indicators ...................21 Component Contents ....................22 Connectors and Components ................23 Jumpers ........................26...
  • Page 3 System Setup......................31 System Cover ......................33 CPU & Heatsink ......................34 Memory ........................38 System Fan......................43 Installing OCP Card ....................45 Air Duct ........................46 Power Supply Unit (PSU) ..................48 Cable Routing ......................49 Slide Rail .........................51 Contents...
  • Page 4: Regulatory Notices

    Chemical Substances Information In compliance with chemical substances regulations, such as the EU REACH Regulation (Regulation EC No. 1907/2006 of the European Parliament and the Council), MSI provides the information of chemical substances in products at: https://csr.msi.com/global/index CE Conformity Hereby, Micro-Star International CO., LTD declares that this device is in compliance with the essential safety requirements and other relevant provisions set out in the European Directive.
  • Page 5: Battery Information

    Battery Information Please take special precautions if this product comes with a battery. Danger of explosion if battery is incorrectly replaced. Replace only with the ● same or equivalent type recommended by the manufacturer. Avoid disposal of a battery into fire or a hot oven, or mechanically crushing or ●...
  • Page 6: Environmental Policy

    US. Copyright and Trademarks Notice Copyright © Micro-Star Int’ l Co., Ltd. All rights reserved. The MSI logo used is a registered trademark of Micro-Star Int’ l Co., Ltd. All other marks and names mentioned may be trademarks of their respective owners.
  • Page 7 Safety Information ⚠ Please read and follow these safety instructions carefully before installing, operating or performing maintenance on the server. General Safety Instructions Always read the safety instructions carefully. ● Keep this User’ s Manual for future reference. ● Keep this equipment away from humidity. ●...
  • Page 8 Installation and Handling This equipment must be installed in restricted access areas by qualified personnel to comply with safety standards set by the NEC and IEC 62368-1, Third Edition, for Information Technology Equipment. Lifting and Placemen Follow occupational health and safety guidelines for manual material handling. ●...
  • Page 9 Safety: IEC/EN 62368-1 ● This equipment is compliant with CB/LVD of Safety: IEC/EN 62368-1: 2014. The elements of the instructional safeguard shall be as follows: element 1a: IEC 60417-6056(2011-05) for moving fan blades or IEC 60417-6057(2011-05) for other moving parts element 2: “Moving part”...
  • Page 10: System Specifications

    System Specifications Model CX271-S3066 SKUs S3066X271RAU24 Form factor • 2U Dimensions • 438mm(17.2” ) Wx 87mm(3.4” ) Hx 764mm(30” )D • Single Intel® Xeon® 6700E-series, 6500P-series and 6700P-series processor, Processor TDP up to 350W Socket • 1 x LGA4710 (Socket E2) •...
  • Page 11 Model CX271-S3066 SKUs S3066X271RAU24 • Chassis Intrusion Security • TPM2.0 module supported (optional) • ASPEED AST1060 Hardware Root of Trust module supported (optional) • 1 x 1000Base-T Dedicated Server Management Port Server • ASPEED AST2600 with AMI MegaRAC based firmware supporting IPMI 2.0 and Management DMTF Redfish API •...
  • Page 12: System Overview

    System Overview 24x2.5 “ NVMe Hot-Swap Drive Bays OCP#0 OCP#0 OCP#1 OCP#1 System Overview...
  • Page 13 USB3.0 Type-A Port This connector is provided for USB peripheral devices. (Speed up to 640 Mbps) ⚠ Important Low-speed devices, such as mouse or keyboard, are suggested to be plugged into the USB 3.0 ports. System Power Button/ LED System Reset Button System Alarm LED NIC Link LEDs M.2 Activity LED...
  • Page 14 System Status LED The System Status LED is provided for indicators for system. Status Description System is running/normal operation System Status LED BMC anomaly detected. Check BMC log for details. Green BMC initialization System Power Button/ LED OCP 3.0 Mezzanine Slot Power Supply Unit System Overview...
  • Page 15: System Led Indicators

    System LED Indicators UID Button/ LED System Power Button/ LED System Reset Button System Alarm LED M.2 Activity LED NIC Link LED NIC Link LED LED State Description Blue System power is on System power is on ACPI S0 state System Power LED Blinking System is sleeping...
  • Page 16: Block Diagram

    Block Diagram CPU0_DIMM_A0 CPU0_DIMM_E0 DDR5 DIMMx2 DDR5 DIMMx2 DDR5 CH E,F DDR5 DIMMx2 DDR5 CH A,B DDR5 DIMMx2 CPU0_DIMM_B1 CPU0_DIMM_F1 Modules Modules Modules Socket E2 Modules CPU0_DIMM_C0 DDR5 CH C,D DDR5 DIMMx2 DDR5 DIMMx2 CPU0_DIMM_G0 DDR5 CH G,H DDR5 DIMMx2 DDR5 DIMMx2 Modules Modules...
  • Page 17: System Storage Topology

    System Storage Topology 24 x 2.5” NVMe Hot-Swap Drive Bays PE7/UPI1 PE8/UPI2 2A 2C 2E 2G 4A 4C 4E 4G 5A 5C 5E 5G 7A 7C 7E 7G 8A 8C 8E 8G System Storage Topology...
  • Page 18: Motherboard Overview

    Motherboard Overview OCP0 OCP1 DC-SCM BATTERY CPLD CPU0 Motherboard Overview...
  • Page 19: Mgt1 Dc-Scm Module

    MGT1 DC-SCM Module Specifications Model MGT1 Form factor DC-SCM v2.0 Dimensions 120mm (4.72") x 420mm (3.54") Chipset ASPEED AST2600 Networking 1 x 1000Base-T dedicated server management port Graphics 1 x mini DisplayPort • 1 x USB 2.0 Type-A port (480 Mbps) •...
  • Page 20: Overview Of Components

    Overview of Components Overview of Components...
  • Page 21: Rear I/O Panel

    Rear I/O Panel 1000Base-T Ethernet COM USB Type-A port Ports (for mgmt.) UID Button & System Reset Button Power Button Mini DisplayPort System Status LED USB 2.0 Type-A Port COM USB Type-A port This port allows for serial data transmission over a USB connection, enabling remote or direct console access.
  • Page 22: System Led Indicators

    System LED Indicators 1000Base-T Ethernet Ports (for mgmt.) UID Button/ LED System Reset Button Link/ Activity LED Speed LED Power Button/ LED System Status LED LED State Description Power LED System power is on Green System power is on ACPI S0 state System is sleeping Blinking System power is off...
  • Page 23: Component Contents

    Component Contents Component Page TPM: SPI TPM Header (for TPM20-IRS) M2_1: M.2 Slot (M Key, for ROT1) J_JTAG: Manual Programming Headers (Debug Use) Jumpers Onboard LED LED1: BMC Heartbeat LED Component Contents...
  • Page 24: Connectors And Components

    Connectors and Components TPM: SPI TPM Header (for TPM20-IRS) This header connects to a TPM (Trusted Platform Module) module (optional). Please refer to the TPM security platform manual for more details. PRSNT# RST# MOSI PIRQ MISO PP/Reserved Installing TPM module 1.
  • Page 25 M2_1: M.2 Slot (M Key, for ROT1) Please install the M.2 3060 module into the M.2 slot as shown below. Installing M.2 3060 module 1. Insert your M.2 module into the M.2 slot at a 30-degree angle. 30° Supplied M.2 screw 2.
  • Page 26 J_JTAG: Manual Programming Header (Debug Use) J_JTAG and J3C5 are used to manually debug and update CPLD firmware with programming tool. Connectors and Components...
  • Page 27: Jumpers

    Jumpers ⚠ Important Avoid adjusting jumpers when the system is on; it will damage the motherboard. Jumper Name Default Setting Description Force BMC Update Jumper J3D2 1-X: Normal (default) 1-2: BMC Force Update FRU Jumper J3C1 1-2: FRU Write Protected 2-3: FRU Normal Operated (default) JTAG SW Jumper J3C5...
  • Page 28: Onboard Led

    Onboard LED LED1: BMC Heartbeat LED This LED indicates the BMC (Baseboard Management Controller) status. Status Description BMC is not activated BMC is functioning normally Blinking Onboard LED...
  • Page 29: Expansion Slots

    Expansion Slots PCIE_SLOT0: PCIe 5.0 x16 MCIO(SFF-TA-1033) Slots PCIE_SLOT1: PCIe 5.0 x16 MCIO(SFF-TA-1033) Slots PCIE_SLOT2: PCIe 5.0 x16 MCIO(SFF-TA-1033) Slots PCIe (Peripheral Component Interconnect Express) Slots The PCI Express slots support PCIe interface expansion cards. ⚠ Important When adding or removing expansion cards, make sure that you unplug the power supply first.
  • Page 30: Connectors

    Connectors Power Connectors PWR1 PICPWR4 PICPWR3 PICPWR5 PICPWR1 PICPWR0 PICPWR0~1/3~5: PIC Power Connectors The PICPWR(Platform Infrastructure Connectivity Power) connector enables the HPM(Host Processor Module) to supply power and manage sideband signals to peripherals,including the GPU Cards (PICPWR3~4), the Power Distribution Board(PICPWR0~1)and the Fan Board(PICPWR5).
  • Page 31 PICPWR0~1/3~5: PIC Power Connectors These connectors provide power output to HPM. Power Signals P12V P12V P12V PICPWR0/PICPWR1 /PICPWR3~5 P12V P12V P12V Sideband Management Signals FM_HPM_PICPWR_B_SB1 FM_HPM_PICPWR_A_SB1 FM_HPM_PICPWR_B_SB2 FM_HPM_PICPWR_A_SB2 FM_HPM_PICPWR_B_SB3 FM_HPM_PICPWR_A_SB3 FM_HPM_PICPWR_B_SB4 FM_HPM_PICPWR_A_SB4 SMB_PICPWR_2B_LVC3_SCL SMB_PICPWR_2A_LVC3_SCL SMB_PICPWR_2B_LVC3_SDA SMB_PICPWR_2A_LVC3_SDA *SB: The term “ SB” stands for sideband. PWR1: Rear Side BP Power Connector This connector provides power output to HDDs on rear side.
  • Page 32 Storage Connectors M2_1 M2_0 JMCIO2 JMCIO4 JMCIO3 JMCIO5 JMCIO0 Slot Speed JMCIO1 M2_0~1 PCIe5.0 x2 32GT/s JMCIO0~5 PCIe5.0 x8 32GT/s JMCIOP0~5: MCIO 8i Connector These are vertical 74-pin Mini Cool Edge IO (MCIO) connectors, which support PCIe 5.0 x16 32GT/s interface. Connectors...
  • Page 33 JMCIO0~5: MCIO 8i Connectors These are vertical 74-pin Mini Cool Edge IO (MCIO) connectors, which support PCIe 5.0 x8 32GT/s interface JMCIO0~5 P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE4_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P3V3_AUX JMCIO_BMC_SCL FM_SMB_PEHPCPU_MCIO_LVC3_ JMCIO_BMC_SDA ALERT_N CLK_100M_CPU_MCIO_R_D+ PCIe_RST_N CLK_100M_CPU_MCIO_R_D- FM_MCIO_CPU_PESTI_CBL_PRES_N P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D...
  • Page 34 USB_HUB_MCIO_CPU_PE_D+ FM_MCIO_CPU_FPGA_FLEXIO_1A USB_HUB_MCIO_CPU_PE_D- FM_MCIO_CPU_FPGA_FLEXIO_2A P5E_CPU_PE_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_RX_D- P5E_CPU_PE_NVME_TX_D Connectors...
  • Page 35 Cooling Connectors JCPUFAN0: CPU Fan Power Connectors The fan power connectors support CPU cooling fans. FAN _TACH JCPUFAN0 P12V FAN_PWM JCPUFAN0 Connectors...
  • Page 36 JUSB3_0: USB 3.0 Connector This port is backward-compatible with USB 3.0 devices and supports data transfer rate up to 5 Gbps. P5V_USB_1 USB2_P3_ESD_DP USB3_P2_ESD_RXN USB2_P3_ESD_DN USB3_P2_ESD_RXP USB3_P3_ESD_TXP USB3_P2_ESD_TXN USB3_P3_ESD_TXN JUSB3_0 USB3_P2_ESD_TXP USB3_P3_ESD_RXP USB2_P2_ESD_DN USB3_P3_ESD_RXN USB2_P2_ESD_DP P5V_USB_2 JUSB3_0 Connectors...
  • Page 37: Other Connectors And Components

    Other Connectors and Components JINTRUDE: Chassis Intrusion Header This connector connects to the chassis intrusion switch cable. If the chassis is opened, the chassis intrusion mechanism will be activated. The system will record this status and show a warning message on the screen. To clear the warning, you must enter the BIOS utility and clear the record.
  • Page 38 J9: PDB Management Connector The PDB Management header connects to the power distribution board (PDB). P12V_STBY_PSU P12V_STBY_PSU ISENSE_I_PSYS_R VSENSE_LOCAL_V_PSYS_R P12V_STBY_PSU P12V_STBY_PSU PDB_SGPIO_LD PDB_SGPIO_CK PDB_SGPIO_DO PDB_SGPIO_DI SMB_PS_CLK_R SMB_PS_DAT_R TP_FULL_PWR_CYCLE_N Other Connectors and Components...
  • Page 39 SFP0~1: DC-MHS Control Panel Header The DC-MHS control panel header for M-PESTI connects the HPM to the server’ sfront panel, enabling essential controls such as power, LED indicators, buttons, and sideband signals for management and monitoring. ・ DC-MHS (Data Center Modular Hardware System) is a modular framework for data center hardware, promoting interoperability across components.
  • Page 40 OCP0~1: OCP 3.0 Mezzanine Slot This slot enables the deployment of a wide variety of additional options through OCP(Open Compute Project) network interface cards (NICs) or other expansion Cards. OCP0: OCP 3.0 SFF OCP1: OCP 3.0 SFF (PCIe 5.0 x16) (PCIe 5.0 x16) OB14 OA14...
  • Page 41 Top Side (B Pins) Bottom Side (A Pins) OB11 OA11 CLK_100M_CPU0_OCP0_3_DN/DP RST_CPU0_PE0_OCP0_PERST2_N OB12 OA12 CLK_100M_CPU0_OCP0_2_DN/DP RST_CPU0_PE0_OCP0_PERST3_N OB13 OA13 IRQ_WAKE_CPU0_PE0_OCP0_LVC3_N OB14 OA14 RMII_OCP0_CSDV OCP0_RBT_ARB_IN Mechanical Key P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 PD_OCP0_NIC_BIF0_N SMB_CPU0_PE2_OCP0_LVC3_SCL PD_OCP0_NIC_BIF1_N SMB_CPU0_PE2_OCP0_LVC3_SDA PD_OCP0_NIC_BIF2_N RST_BMC_PCIE_MUX_R_LVC3_N RST_CPU0_PE7_OCP0_PERST0_N PD_CPU0_OCP0_NIC_PRSNTA_N P3V3_AUX_OCP0 RST_CPU0_PE7_OCP0_PERST1_N FM_OCP0_NIC_AUX_PWR_LVC3_R_EN FM_CPU_PE_OCP0_NIC_PRSTN2_N...
  • Page 42 Mechanical Key P5E_CPU0_PE2_OCP_TX_DN4 P5E_CPU0_PE2_OCP_RX_DN4 P5E_CPU0_PE2_OCP_TX_DP4 P5E_CPU0_PE2_OCP_RX_DP4 P5E_CPU0_PE2_OCP_TX_DN5 P5E_CPU0_PE2_OCP_RX_DN5 P5E_CPU0_PE2_OCP_TX_DP5 P5E_CPU0_PE2_OCP_RX_DP5 P5E_CPU0_PE2_OCP_TX_DN6 P5E_CPU0_PE2_OCP_RX_DN6 P5E_CPU0_PE2_OCP_TX_DP6 P5E_CPU0_PE2_OCP_RX_DP6 P5E_CPU0_PE2_OCP_TX_DN7 P5E_CPU0_PE2_OCP_RX_DN7 P5E_CPU0_PE2_OCP_TX_DP7 P5E_CPU0_PE2_OCP_RX_DP7 Top Side (B Pins) Bottom Side (A Pins) FM_CPU0_OCP0_NIC_PRSTN0_N FM_CPU_OCP0_NIC_PRSTN1_N Mechanical Key P5E_CPU0_PE2_OCP_TX_DN8 P5E_CPU0_PE2_OCP_RX_DN8 P5E_CPU0_PE2_OCP_TX_DP8 P5E_CPU0_PE2_OCP_RX_DP8 P5E_CPU0_PE2_OCP_TX_DN9 P5E_CPU0_PE2_OCP_RX_DN9 P5E_CPU0_PE2_OCP_TX_DN9 P5E_CPU0_PE2_OCP_RX_DP9 P5E_CPU0_PE2_OCP_TX_DN10 P5E_CPU0_PE2_OCP_RX_DN10 P5E_CPU0_PE2_OCP_TX_DP10 P5E_CPU0_PE2_OCP_RX_DP10 P5E_CPU0_PE2_OCP_TX_DN11...
  • Page 43 P5E_CPU0_PE2_OCP_TX_DN12 P5E_CPU0_PE2_OCP_RX_DN12 P5E_CPU0_PE2_OCP_TX_DP12 P5E_CPU0_PE2_OCP_RX_DP12 P5E_CPU0_PE2_OCP_TX_DN13 P5E_CPU0_PE2_OCP_RX_DN13 P5E_CPU0_PE2_OCP_TX_DP13 P5E_CPU0_PE2_OCP_RX_DP13 P5E_CPU0_PE2_OCP_TX_DN14 P5E_CPU0_PE2_OCP_RX_DN14 P5E_CPU0_PE2_OCP_TX_DP14 P5E_CPU0_PE2_OCP_RX_DP14 P5E_CPU0_PE2_OCP_TX_DN15 P5E_CPU0_PE2_OCP_RX_DN15 P5E_CPU0_PE2_OCP_TX_DP15 P5E_CPU0_PE2_OCP_RX_DP15 FM_CPU0_PE0_OCP0_PRSTN3_QS_N USB2_OCP_NIC_DN USB2_OCP_NIC_DP FM_PWRBRK_CPU0_PE2_OCP0_ FM_CPU_PE_OCP0_NIC_PRSNTB3_N LVC3_N Other Connectors and Components...
  • Page 44 DC-SCM: DC-SCM 2.0 Edge Slot The slot links the Datacenter Secure Control Module (DC-SCM) to the motherboard, enabling centralized power, management, and security control across server hardware. This standardized interface allows easy upgrades and compatibility across various platforms. DC-SCM: DC-SCM 2.0 Edge Slot (PCIe 5.0 x1 from CPU0) OB14 OA14...
  • Page 45 Top Side (B Pins) Bottom Side (A Pins) OB11 OA11 USB2_BMC_HUB_DN OB12 OA12 USB2_BMC_HUB_DP OB13 OA13 OB14 OA14 P1V0_AUX PECI_SCM Mechanical Key CLK_66M_ESPI_CPU0_LVC18 P12V_AUX_SCM ESPI_CPU0_CS0_SCM_N P12V_AUX_SCM RST_ESPI_CPU0_LVC18_N P12V_AUX_SCM ESPI_CPU0_IO0_LVC18 P12V_AUX_SCM ESPI_CPU0_IO1_LVC18 ESPI_CPU0_IO2_LVC18 ESPI_CPU0_IO3_LVC18 IRQ_ESPI_CPU0_ALERT0_FPGA_ BMC_JTAG_LVC3_TCK LVC18_N BMC_JTAG_LVC3_TDI BMC_JTAG_LVC3_TDO BMC_JTAG_LVC3_TMS SPI_CPU0_CLK_DCSCM_LVC18_R1 SPI_CPU0_CS0_DCSCM_LVC18_R1_N FM_HPM_STBY_RST_N SPI_CPU0_IO0_DCSCM_LVC18_R1...
  • Page 46 P3V_BAT_CPU0 RST_PLD_PCIE_CPU0_DEV_PERST_N Mechanical Key P5E_CPU0_PE1_TX_DN2 P5E_CPU0_PE1_RX_DN2 P5E_CPU0_PE1_TX_DP2 P5E_CPU0_PE1_RX_DP2 HUB_SSTX4N HUB_SSRX4N HUB_SSTX4P HUB_SSRX4P BMC_TYPEA_DN CLK_100M_SCM_DN BMC_TYPEA_DP CLK_100M_SCM_DP I3C_DBG_SCM_LVC18_R_SCL I3C_SPD_SCM_R_LVC1_SCL I3C_DBG_SCM_LVC18_R_SDA I3C_SPD_SCM_R_LVC1_SDA I3C_MNG_SCM_LVC1_R_SCL Top Side (B Pins) Bottom Side (A Pins) I3C_MNG_SCM_LVC1_R_SDA Mechanical Key CLK3_50M_SCM_RMII_CLK SMB_PCIE_SCM_LVC3_R_SCL RMII3_SCM_CRS_DV_R SMB_PCIE_SCM_LVC3_R_SDA RMII3_SCM_TX_EN_R SMB_IPMB_LVC3_CLK RMII3_SCM_TXD0 SMB_IPMB_LVC3_DAT RMII3_SCM_TXD1 SMB_CPLD_UPDATE_SCM_LVC3_R_SCL RMII3_SCM_RXD0...
  • Page 47 SMB16_IPMB_LVC3_SCL SPI_CPU0_TPM_MOSI_LVC18_MUX_R1 SMB16_IPMB_LVC3_SDA SPI_CPU0_TPM_MISO_LVC18_MUX_R1 FM_SCM_PRSNT0_LVC3_N SCM_GPIO SPI_BMC_FP_CK_R SPI_IRQ_SCM_TPM_N SPI_BMC_FP_MISO_R SPI_BMC_FP_MOSI_R SPI_BMC_FP_CS0_R UART0_RX_HPM_SCM_DATA BMC_USB2A_DN BMC_USB2A_DP Other Connectors and Components...
  • Page 48 JVROC1: VROC Box Header Intel® Virtual RAID on CPU (Intel® VROC) is a hybrid RAID solution specifically designed for NVMe SSDs connected directly to the CPU. PU_KEY_CONN_PIN2_R JVROC1 FM_PCH_SATA_RAID_KEY_R FBP_I2C_1~3: HDD BP SMBUS Header I2C headers are used to connect to the System Management Bus (SMBus). FBP_ I2C_1~3 is for HDD backplanes.
  • Page 49: Jumpers

    Jumpers ⚠ Important Avoid adjusting jumpers when the system is on; it will damage the motherboard. CMOS_CLR JBAT1 JTAG_SEL2 JUART_SEL_1 JBAT7 Jumper Name Default Setting Description 1-2: Normal<Default> CMOS_CLR 2-3: CPU0 CMOS Clear 1-2 UART BMC TO CPU<Default> JUART_SEL_1 2-3 UART CPLD TO CPU 1-2 MBP Functionality JBAT1 <Default>...
  • Page 50: Onboard Leds

    Onboard LEDs HB_LED1: PSU_PWROK_ LED This LED indicates the PSU power status. Status Description PSU power fail HEARTBEAT_LED1 Blinking PSU power OK HEARTBEAT_LED1 HB_LED2: CPLD HEARTBEAT LED, CPU0 PRST LED1: PLT_RST The CPLD Heartbeat LED indicates CPLD status.The CPU PRST LED1 indicates all voltage inputs to the processor are in specification.
  • Page 51 PWRGD_CPU0_LED1: PSU_PWROK_ LED,CPU0_POK_ LED1:CPU0 SYS PWR OK LED This PWRGD_CPU0_LED1 indicates CPU PWROK & CLK status. The CPU0_POK_ LED1 indicates CPU PWROK status Status Description CPU CLK is no Ready PWRGD_ All CPU power & CLK CPU0_LED1 is Ready CPU Power Fail CPU0_POK_ LED1 CPU Power OK...
  • Page 52: Getting Started

    Getting Started ⚠ Important All information is subject to change without prior notice. • The system photos are provided for demonstration purposes only. The • appearance and internal view of your system may vary depending on the model you purchased. Necessary Tools Anti-Static Screwdriver...
  • Page 53: System Setup

    System Setup ⚠ Important Before removing or installing any components, make sure the system is not turned on or connected to the power. Drive Bay Installing 2.5" HDD/ SSD 1. Carefully pull over the lever open. 2. With the lever open, pull out the HDD tray. System Setup...
  • Page 54 3. Engage two embossed pins into the side dimples on the HDD/ SSD. 4. Carefully push down the other side of the HDD/ SSD until another two embossed pins and side dimples lock it into place. 5. With the lever open, insert the 2.5” HDD/ SSD assembly vertically into the drive bay until the locking lever is engaged.
  • Page 55: System Cover

    System Cover Removing System Cover Remove the screws securing the system on both sides. To remove the top cover panels, lift over the release latches and then slide them to the back side of the system. System Cover...
  • Page 56: Cpu & Heatsink

    CPU & Heatsink Use appropriate ground straps, gloves and ESD mats to protect yourself from electrostatic discharge (ESD) while installing the processor. Assembly Overview ⚠ Important Images are for illustration purposes only; actual parts may vary. Heatsink Processor CPU Carrier Heatsink Module (PHM) Socket...
  • Page 57 1. Place the processor carrier on top of the processor in the tray with their pin 1 indicators aligned. If installed properly, the CPU will snap into the carrier’ s side latches and the carrier will latch firmly to it. Verify that the processor is securely latched to the carrier.
  • Page 58 4. Check the heatsink for a diagonally cut corner or the #1clip on the heatsink label if present. Align the processor carrier’ s Pin 1 indicator with the heatsink’ s cut corner (#1 clip), then gently press the heatsink down to engage the carrier’ s latching mechanism to the heatsink at four corners.
  • Page 59 7. Flip 4 anti-tilt wires to the locked position (outward) and make sure the latches of the wires are firmly secure. 4 x anti-tilt wires locked 8. Tighten all screws on the PHM in diagonal sequences to secure the PHM to the motherboard.
  • Page 60: Memory

    Memory CPU0_DIMM_H0 Channel H CPU0_DIMM_H1 CPU0_DIMM_G0 Channel G CPU0_DIMM_G1 CPU0_DIMM_F0 Channel F CPU0_DIMM_F1 Channel E CPU0_DIMM_E0 CPU0_DIMM_E1 CPU0 CPU0_DIMM_A1 Channel A CPU0_DIMM_A0 Channel B CPU0_DIMM_B1 CPU0_DIMM_B0 CPU0_DIMM_C1 Channel C CPU0_DIMM_C0 Channel D CPU0_DIMM_D1 CPU0_DIMM_D0 Memory...
  • Page 61: Recommended Memory Population

    Chan 7 Chan 6 Chan 5 Chan 4 Chan 0 Chan 1 Chan 2 Chan 3 IMC5 IMC4 IMC0 IMC1 IMC2 IMC3 IMC7 IMC6 Recommended Memory Population Granite Rapids-SP DDR DIMM Support Matrix Support Matrix for Intel Xeon 6500P/6700P-series DIMM Capacity(GB) Channel Speed(MT/s);...
  • Page 62 DDR5 Only DIMM Configuration SPR IMC# IMC7 IMC6 IMC5 IMC4 IMC0 IMC1 IMC2 IMC3 Channel Chan 7 Chan 6 Chan 5 Chan 4 Chan 0 Chan 1 Chan 2 Chan 3 DDR5 H0 H1 G0 G1 F0 F1 E0 E1 A1 A0 B1 B0 C1 C0 D1 D0 12+0 16+0...
  • Page 63: Installing Memory Modules

    Installing Memory Modules 1. Open the side clips to unlock the DIMM slot. 2. Insert the DIMM vertically into the slot, ensuring that the off-center notch at the bottom aligns with the slot. 3. Push the DIMM firmly into the slot until it clicks and the side clips automatically close.
  • Page 64 Installing M.2 SSD onto the Server Board ⚽ Video Demonstration Watch the video to learn how to Install M.2 SSD. 1. Insert your M.2 SSD into the M.2 slot at a 30-degree angle. 30° 2. Secure the M.2 SSD in place with the M.2 latch.
  • Page 65: System Fan

    System Fan The server system is equipped with six 60 x 60 x 56mm hot-swappable system fans that provide primary airflow to maintain optimal cooling and prevent overheating. The fan features include: Tachometer on each fan allows BMC to monitor the system’ s status in real-time. •...
  • Page 66 Installing 2U Fan Cage 1. Press the release tabs and lift the fan to remove it from the cage. Ensure all cables are clear of the fan cage installation area before proceeding. • 2. Align the guiding rails and lower the fan cage onto the system’ s base. Then push down the latches to lock it into place.
  • Page 67: Installing Ocp Card

    Installing OCP Card 1. Unscrew to relese the OCP dummy bracket. 2. Insert the OCP Card into the OCP bay and secure the rotary screw. Installing OCP Card...
  • Page 68: Air Duct

    Air Duct The server system offers a pre-installed plastic air duct available as an accessory. ⚠ Important After installing the air duct, the middle GPU bar have to be reinstalled to the • chassis. Installing Air Duct 1. Install the air duct to the chassis. Air Duct...
  • Page 69 2. Align the pins on the front edge of the air duct with the holes on the fan wall, then lower the air duct into place until it is securely seated Air Duct...
  • Page 70: Power Supply Unit (Psu)

    Power Supply Unit (PSU) The server system supports two power supplies that can be easily inserted and removed from the rear side of the system without the need for tools. ⚠ Important Both power supplies must be identical and both power cords should be •...
  • Page 71: Cable Routing

    Cable Routing ⚠ Important Please remove the fan cage before routing cables. I2C to I2C Cable (HDD Backplane to MB) 12-pin to 12-pin Power Cable (PDB to MB/ HDD BP) PICPWR1 PICPWR0 Cable Routing...
  • Page 72 12-pin to 12-pin Power Cable (Fan BP to MB) PICPWR5 MCIO 8i to MCIO 8i Cable(HDD BP to MB) PCIE_SLOT0 PCIE_SLOT1 PCIE_SLOT2 JMCIO5 JMCIO0 JMCIO1 JMCIO2 JMCIO3 JMCIO4 Cable Routing...
  • Page 73: Slide Rail

    Slide Rail ⚠ Important The pre-installed screws on the outer rail bracket are intended only for square rack holes. For round holes, please switch to the “7.1 round hole screw” . 9.5 Square Hole Screw (pre-installed) 7.1 Round Hole Screw Disassembling Slide Rail Slide the release tab forward to separate the inner rail from the bracket.
  • Page 74 Installing Inner Rail to System 1. Align the standoffs on the side of the system with the hole on the inner rail, then pull the inner rail backwards till it locks into place. 2. Tighten the screw to secure the inner rail. 3.
  • Page 75 Retracting Outer Rail Bracket Pull the latch downward to slide the middle rail back to the outer rail bracket. Middle Rail Attaching Outer Rail Bracket to Rack Frame Slide Rail...
  • Page 76 Installing System into Rack 1. Pull out the middle rails till it fully extended. 2. Engage the inner rails of the system to the middle rails, then push the system forward until it stops. 3. Push the system into the rack by sliding the two-way release tabs forward or backward.
  • Page 77 Detaching Outer Rail Bracket from Rack Frame Detaching Inner Rail from System Slide Rail...
  • Page 78 MSI.COM EPS.MSI.COM...