  • Page 1 CD270-S4051-X4 MS-S382 Server System User Guide...
  • Page 2: Table Of Contents

    Contents Regulatory Notices ....................4 Safety Information ....................7 ⚠ Please read and follow these safety instructions carefully before installing, ....7 System Specifications ...................10 System Overview ....................12 Block Diagram ......................15 System Storage Topology ..................16 Overview of Components ..................17 MGT1 DC-SCM Module ...................18 Specifications ......................18 Overview of Components ..................19 Rear I/O Panel ......................20...
  • Page 3 Power Connectors ....................41 Cooling Connectors ....................44 USB Header ......................45 Other Connectors and Component ..............46 Jumpers ........................59 Onboard LEDs......................60 Onboard LEDs......................61 Getting Started .......................62 System Setup......................63 System Node ......................63 Drive Bay .........................64 OCP Card ........................65 DC-SCM Module ......................66 System Fan......................67 Air Duct ........................69 Power Supply Unit (PSU) ..................70 Cable Routing ......................71 Slide Rail .........................50...
  • Page 4: Regulatory Notices

    Chemical Substances Information In compliance with chemical substances regulations, such as the EU REACH Regulation (Regulation EC No. 1907/2006 of the European Parliament and the Council), MSI provides the information of chemical substances in products at: https://csr.msi.com/global/index CE Conformity Hereby, Micro-Star International CO., LTD declares that this device is in compliance with the essential safety requirements and other relevant provisions set out in the European Directive.
  • Page 5: Battery Information

    Battery Information Please take special precautions if this product comes with a battery. Danger of explosion if battery is incorrectly replaced. Replace only with the ● same or equivalent type recommended by the manufacturer. Avoid disposal of a battery into fire or a hot oven, or mechanically crushing or ●...
  • Page 6: Environmental Policy

    US. Copyright and Trademarks Notice Copyright © Micro-Star Int’ l Co., Ltd. All rights reserved. The MSI logo used is a registered trademark of Micro-Star Int’ l Co., Ltd. All other marks and names mentioned may be trademarks of their respective owners.
  • Page 7: Safety Information

    Safety Information ⚠ Please read and follow these safety instructions carefully before installing, operating or performing maintenance on the server. General Safety Instructions Always read the safety instructions carefully. ● Keep this User’ s Manual for future reference. ● Keep this equipment away from humidity. ●...
  • Page 8 Installation and Handling This equipment must be installed in restricted access areas by qualified personnel to comply with safety standards set by the NEC and IEC 62368-1, Third Edition, for Information Technology Equipment. Lifting and Placemen Follow occupational health and safety guidelines for manual material handling. ●...
  • Page 9 Safety: IEC/EN 62368-1 ● This equipment is compliant with CB/LVD of Safety: IEC/EN 62368-1: 2014. The elements of the instructional safeguard shall be as follows: element 1a: IEC 60417-6056(2011-05) for moving fan blades or IEC 60417-6057(2011-05) for other moving parts element 2: “Moving part”...
  • Page 10: System Specifications

    System Specifications Model CD270-S4051-X4 SKUs S4051D270RAU3-X4 Form factor • 2U4N Dimensions • 448mm(17.2” ) Wx87mm(3.4” ) Hx745mm(29.3” ) • Single AMD EPYC™ 9004 Series Processor and EPYC™ 9005 Series Processor processors, up to TDP 360W, per node Socket • 1 x LGA6096 (Socket SP5) per node •...
  • Page 11 Model CD270-S4051-X4 SKUs S4051D270RAU3-X4 • 1 x EVAC air cooling modules for max. 360W CPU per node Cooling • 4 x Rear 8080 Hot-swap FANs per system • System Operating Temperature: 0°C ~ 35°C (50°F ~ 95°F) Environment • Non-operating Temperature: -20°C ~ 70°C (-4°F to 158°F) •...
  • Page 12: System Overview

    System Overview 2.5” NVMe Hot-Swap Drive Bays 2.5” NVMe Hot-Swap Drive Bays 2.5” NVMe Hot-Swap Drive Bays 2.5” NVMe Hot-Swap Drive Bays System Fans System Fans System Fans System Fans System Overview...
  • Page 13 COM USB Type A port USB 2.0 Type-A Port This connector is provided for USB peripheral devices. (Speed up to 480 Mbps) ⚠ Important High-speed devices are recommended for USB 3.2 ports whereas low- speed devices, such as mouse or keyboard, are suggested to be plugged into the USB 2.0 ports.
  • Page 14 System Fan1&Fan2 (from left to right) Power Supply Unit System Fan3&Fan4 (from left to right) System Overview...
  • Page 15: Block Diagram

    Block Diagram CPU0_DIMM_A0 CPU0 CPU0_DIMM_G0 DDR5 1DPC DDR5 CH A~F DDR5 CH G-L DDR5 1DPC CPU0_DIMM_F0 CPU0_DIMM_L0 DIMMx6 Socket SP5 DIMMx6 PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) PCIE Gen5(x16) 2 x MCIO 8i 2 x MCIO 8i...
  • Page 16: System Storage Topology

    System Storage Topology Node #3 Node #3 Node #1 Node #1 Node #0 Node #0 Node #2 Node #2 NVMe #0 NVMe #0 NVMe #1 NVMe #1 NVMe #2 NVMe #2 12 x 2.5” NVMe Hot-Swap Drive Bays NVMe #0 NVMe #1 NVMe #2 Lane: 8-15...
  • Page 17: Overview Of Components

    Overview of Components FBP_I2C_3 FBP_I2C_2 CPLD BATTERY CPU0 Overview of Components...
  • Page 18: Mgt1 Dc-Scm Module

    MGT1 DC-SCM Module Specifications Model MGT1 Form factor DC-SCM v2.0 Dimensions 120mm (4.72") x 420mm (3.54") Chipset ASPEED AST2600 Networking 1 x 1000Base-T dedicated server management port Graphics 1 x mini DisplayPort • 1 x USB 2.0 Type-A port (480 Mbps) •...
  • Page 19: Overview Of Components

    Overview of Components Overview of Components...
  • Page 20: Rear I/O Panel

    Rear I/O Panel 1000Base-T Ethernet COM USB Type-A port Ports (for mgmt.) UID Button & System Reset Button Power Button Mini DisplayPort USB 2.0 Type-A Port System Status LED COM USB Type-A port This port allows for serial data transmission over a USB connection, enabling remote or direct console access.
  • Page 21: System Led Indicators

    System LED Indicators 1000Base-T Ethernet Ports (for mgmt.) UID Button/ LED System Reset Button Link/ Activity LED Speed LED Power Button/ LED System Status LED LED State Description Power LED System power is on Green System power is on ACPI S0 state System is sleeping Blinking System power is off...
  • Page 22: Component Contents

    Component Contents Component Page TPM: SPI TPM Header (for TPM20-IRS) M2_1: M.2 Slot (M Key, for ROT1) J_JTAG: Manual Programming Headers (Debug Use) Jumpers Onboard LED LED1: BMC Heartbeat LED Component Contents...
  • Page 23: Connectors And Components

    Connectors and Components TPM: SPI TPM Header (for TPM20-IRS) This header connects to a TPM (Trusted Platform Module) module (optional). Please refer to the TPM security platform manual for more details. PRSNT# RST# MOSI PIRQ MISO PP/Reserved Installing TPM module 1.
  • Page 24 M2_1: M.2 Slot (M Key, for ROT1) Please install the M.2 3060 module into the M.2 slot as shown below. Installing M.2 3060 module 1. Insert your M.2 module into the M.2 slot at a 30-degree angle. 30° Supplied M.2 screw 2.
  • Page 25 J_JTAG: Manual Programming Header (Debug Use) J_JTAG and J3C5 are used to manually debug and update CPLD firmware with programming tool. Connectors and Components...
  • Page 26: Jumpers

    Jumpers ⚠ Important Avoid adjusting jumpers when the system is on; it will damage the motherboard. Default Jumper Name Description Setting Force BMC Update Jumper J3D2 1-X: Normal (default) 1-2: BMC Force Update FRU Jumper J3C1 1-2: FRU Write Protected 2-3: FRU Normal Operated (default) JTAG SW Jumper J3C5...
  • Page 27: Onboard Led

    Onboard LED LED1: BMC Heartbeat LED This LED indicates the BMC (Baseboard Management Controller) status. Status Description BMC is not activated BMC is functioning normally Blinking Onboard LED...
  • Page 28 P0_DIM_F0 P0_DIM_E0 P0_DIM_D0 P0_DIM_C0 P0_DIM_B0 P0_DIM_A0 CPU0 P0_DIM_G0 P0_DIM_H0 P0_DIM_I0 P0_DIM_J0 P0_DIM_K0 P0_DIM_L0 Onboard LED...
  • Page 29: Rear I/O Panel

    Rear I/O Panel DC-SCM PCIe 5.0 x16 OCP3 Edge slot for DC NIC Mezzanine Slot SCM module OCP 3.0 NIC Mezzanine Slot OCP NIC 3.0 is an upgrade of OCP Mezz 2.0. It supports two sizes, SFF and LFF. The maximum power of SFF is 80W, and LFF can reach 150W, It is compatible with PCIe Gen 4 and Gen 5.
  • Page 30: Block Diagram

    Block Diagram CPU0_DIMM_A0 CPU0 CPU0_DIMM_G0 DDR5 1DPC DDR5 CH A~F DDR5 CH G-L DDR5 1DPC CPU0_DIMM_F0 CPU0_DIMM_L0 DIMMx6 Socket SP5 DIMMx6 PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) 2 x MCIO 8i PCIE Gen5(x16) PCIE Gen5(x16) 2 x MCIO 8i 2 x MCIO 8i...
  • Page 31: Cpu Socket

    CPU Socket CPU0 ⚠ Important Overheating will seriously damage the CPU and system. Always make sure the • cooling fan can work properly to protect the CPU from overheating. Make sure that you apply an even layer of thermal paste (or thermal tape) between the CPU and the heatsink to enhance heat dissipation.
  • Page 32: Cpu Installation

    CPU Installation Use appropriate ground straps, gloves and ESD mats to protect yourself from electrostatic discharge (ESD) while installing the processor. ⚠ Important Images are for illustration purposes only; actual parts may vary. 1. Remove the screw on the top of the retention frame. 2.
  • Page 33 4. Pull the external cap upward through the rail guides on the rail frame to remove it. 5. Grip the handle of the carrier frame and slide it downward with the flanges and the rail guides aligned. CPUs are shipped from the factory with pre-assembled carrier frames. •...
  • Page 34 7. Push the retention frame downward and use a torque screwdriver to tighten the screw in the middle. Torque Screwdriver Settings Screw Head: Torx T20 Torque: 12.5-15 kgf·cm* *12.5-15 kgf·cm = 122.6~147 N·m = 10.9~13 lbf·in 8. For peak thermal performance, apply proper amount of thermal paste to the bottom center of the heatsink.
  • Page 35: Memory Slots

    Memory Slots P0_DIM_A0~L0: DDR5 DIMM Slots P0_DIM_F0 P0_DIM_E0 P0_DIM_D0 P0_DIM_C0 P0_DIM_B0 P0_DIM_A0 CPU0 P0_DIM_G0 P0_DIM_H0 P0_DIM_I0 P0_DIM_J0 P0_DIM_K0 P0_DIM_L0 Memory Slots...
  • Page 36: Recommended Memory Population

    Recommended Memory Population CPU0 D C B 1 CPU Channel Qty. of DDR5 “V” indicates DIMMs are populated with DDR5. ⚠ Important There should be at least one DDR5 DIMM populated. Memory Slots...
  • Page 37: Installing Memory Modules

    Installing Memory Modules 1. Open the side clips to unlock the DIMM slot. 2. Insert the DIMM vertically into the slot, ensuring that the off-center notch at the bottom aligns with the slot. 3. Push the DIMM firmly into the slot until it clicks and the side clips automatically close.
  • Page 38: Storage Connectors

    Storage Connectors M2_1 M2_0 JMCIO4 JMCIO3 JMCIO1 JMCIO5 JMCIO2 JMCIO0 JMCIO8 JMCIO7 JMCIO6 JMCIO9 Name Description JMCIO0~9 PCIe 5.0 x8, 32GT/s M2_0~1 PCIe 3.0 x2, 8GT/s JMCIO0~9: MCIO 8i Connectors These are vertical 74-pin Mini Cool Edge IO (MCIO) connectors, which support PCIe 5.0 x8 32GT/s interface JMCIO0~7 P5E_CPU_PE_NVME_RX_D+...
  • Page 39 P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P3V3_AUX JMCIO_BMC_SCL FM_SMB_PEHPCPU_MCIO_LVC3_ALERT_N JMCIO_BMC_SDA CLK_100M_CPU_MCIO_R_D+ PCIe_RST_N CLK_100M_CPU_MCIO_R_D- FM_MCIO_CPU_PESTI_CBL_PRES_N P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_NVME_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_NVME_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_RX_D- P5E_CPU_PE_NVME_TX_D+ SMB_MCIOP_CPU_SCL FM_MCIO_CPU_FPGA_FLEXIO_3A SMB_MCIOP_CPU_SDA FM_MCIO_CPU_FPGA_FLEXIO_4A USB_HUB_MCIO_CPU_PE_D+ FM_MCIO_CPU_FPGA_FLEXIO_1A USB_HUB_MCIO_CPU_PE_D- FM_MCIO_CPU_FPGA_FLEXIO_2A P5E_CPU_PE_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_RX_D- P5E_CPU_PE_NVME_TX_D P5E_CPU_PE_RX_D+ P5E_CPU_PE_NVME_TX_D+ P5E_CPU_PE_RX_D- P5E_CPU_PE_NVME_TX_D Storage Connectors...
  • Page 40 M2_0~1: M.2 Slots (M Key, PCIe 3.0 x2, 2280) Please install the M.2 solid-state drive (SSD) into the M.2 slot as shown below. Installing M.2 SSD ⚽ Video Demonstration Watch the video to learn how to Install M.2 SSD. 1. Insert your M.2 SSD into the M.2 slot at a 30-degree angle.
  • Page 41: Power Connectors

    Power Connectors JPICPWR2 JPWR0 JPICPWR4 JPWR1 JPICPWR3 JPCPWR0 JPCPWR1 JPICPWR0~4: PIC Power Connectors The PICPWR(Platform Infrastructure Connectivity Power) connector enables the HPM(Host Processor Module) to supply power and manage sideband signals to peripherals,including the GPU Cards (JPICPWR2~3), the HDD backplane Board(JPICPWR4)and 12V Power in connector(JPICPWR0~1).
  • Page 42 JPICPWR2~3: 12-Pin GPU Power Connectors These connectors provide power output to GPUs. Power Signals P12V P12V P12V P12V P12V JPICPWR2/JPICPWR3 P12V Sideband Management Signals FM_HPM_PICPWR3_B_SB1/ FM_HPM_PICPWR3_A_SB1/ FM_HPM_PICPWR4_B_SB1 FM_HPM_PICPWR4_A_SB1 FM_HPM_PICPWR3_B_SB2/ FM_HPM_PICPWR3_A_SB2/ FM_HPM_PICPWR4_B_SB2 FM_HPM_PICPWR4_A_SB2 FM_HPM_PICPWR3_B_SB3/ FM_HPM_PICPWR3_A_SB3/ FM_HPM_PICPWR4_B_SB3 FM_HPM_PICPWR4_A_SB3 FM_HPM_PICPWR3_B_SB4/ FM_HPM_PICPWR3_A_SB4/ FM_HPM_PICPWR4_B_SB4 FM_HPM_PICPWR4_A_SB4 SMB_PICPWR_3B_LVC3_SCL/ SMB_PICPWR_3A_LVC3_SCL/ SMB_PICPWR_4B_LVC3_SCL...
  • Page 43 JPICPWR0~1: 12-Pin 12V Power in Connectors These connectors provide power output to GPUs. Power Signals P12V P12V P12V P12V P12V P12V JPICPWR0/JPICPWR1 Sideband Management Signals FM_HPM_PICPWR1_B_SB1/ FM_HPM_PICPWR1_A_SB1/ FM_HPM_PICPWR2_B_SB1 FM_HPM_PICPWR2_A_SB1 FM_HPM_PICPWR1_B_SB2/ FM_HPM_PICPWR1_A_SB2/ FM_HPM_PICPWR2_B_SB2 FM_HPM_PICPWR2_A_SB2 FM_HPM_PICPWR1_B_SB3/ FM_HPM_PICPWR1_A_SB3/ FM_HPM_PICPWR2_B_SB3 FM_HPM_PICPWR2_A_SB3 FM_HPM_PICPWR1_B_SB4/ FM_HPM_PICPWR1_A_SB4/ FM_HPM_PICPWR2_B_SB4 FM_HPM_PICPWR2_A_SB4 SMB_IPMB1_SCL/ SMB_PICPWR_1A_LVC3_SCL/...
  • Page 44: Cooling Connectors

    Cooling Connectors JCPUFAN0 JCPUFAN0: CPU Fan Connectors The fan power connectors support CPU cooling fans. JCPUFAN0 P12V Cooling Connectors...
  • Page 45: Usb Header

    USB Header JUSB3_0 JUSB3_0: USB 3.0 Connector This port is backward-compatible with USB 3.0 devices and supports data transfer rate up to 5 Gbps. P5V_USB_1 USB2_P3_ESD_DP USB3_P2_ESD_RXN USB2_P3_ESD_DN USB3_P2_ESD_RXP USB3_P3_ESD_TXP USB3_P2_ESD_TXN USB3_P3_ESD_TXN JUSB3_0 USB3_P2_ESD_TXP USB3_P3_ESD_RXP USB2_P2_ESD_DN USB3_P3_ESD_RXN USB2_P2_ESD_DP P5V_USB_2 USB Header...
  • Page 46: Other Connectors And Component

    Other Connectors and Component J1: PDB Management Connector The PDB Management header connects to the power distribution board (PDB). P12V_STBY P12V_STBY P12V_STBY P12V_STBY SGPIO_LOAD SGPIO_CLK SGPIO_DATAOUT SGPIO_DATAIN SMB_PSU_SCL SMB_PSU_SDA Other Connectors and Component...
  • Page 47 J2: Liquid Leakage Detect Connector This header is to header for liquid cooler leaking sensor. P12V_AUX LIQUID_INT CBL_PRSNT J3: Pump Driver Connector This header is to pump driver. P12V PUMP1_TACH PUMP1_PWM PUMP2_TACH PUMP2_PWM Other Connectors and Component...
  • Page 48 SFP0~1: DC-MHS Control Panel Header The DC-MHS control panel header for M-PESTI connects the HPM to the server’ sfront panel, enabling essential controls such as power, LED indicators, buttons, and sideband signals for management and monitoring. DC-MHS (Data Center Modular Hardware System) is a modular framework ●...
  • Page 49 OCP0~1: OCP 3.0 Mezzanine Slot This slot enables the deployment of a wide variety of additional options through OCP(Open Compute Project) network interface cards (NICs) or other expansion Cards. OCP0: OCP 3.0 SFF (PCIe 5.0 x16) Top Side (B Pins) Bottom Side (A Pins) PWRGD_OCP0_NIC1_PWRGD_R RST_CPU0_PE0_OCP0_PERST2_N...
  • Page 50 Top Side (B Pins) Bottom Side (A Pins) OB11 OA11 CLK_100M_CPU0_OCP0_3_DN/DP RST_CPU0_PE0_OCP0_PERST2_N OB12 OA12 CLK_100M_CPU0_OCP0_2_DN/DP RST_CPU0_PE0_OCP0_PERST3_N OB13 OA13 IRQ_WAKE_CPU0_PE0_OCP0_LVC3_N OB14 OA14 RMII_OCP0_CSDV OCP0_RBT_ARB_IN Mechanical Key P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 P12V_AUX_OCP0 PD_OCP0_NIC_BIF0_N SMB_CPU0_PE2_OCP0_LVC3_SCL PD_OCP0_NIC_BIF1_N SMB_CPU0_PE2_OCP0_LVC3_SDA PD_OCP0_NIC_BIF2_N RST_BMC_PCIE_MUX_R_LVC3_N RST_CPU0_PE7_OCP0_PERST0_N PD_CPU0_OCP0_NIC_PRSNTA_N P3V3_AUX_OCP0 RST_CPU0_PE7_OCP0_PERST1_N FM_OCP0_NIC_AUX_PWR_LVC3_R_EN FM_CPU_PE_OCP0_NIC_PRSTN2_N...
  • Page 51 Mechanical Key P5E_CPU0_PE2_OCP_TX_DN4 P5E_CPU0_PE2_OCP_RX_DN4 P5E_CPU0_PE2_OCP_TX_DP4 P5E_CPU0_PE2_OCP_RX_DP4 P5E_CPU0_PE2_OCP_TX_DN5 P5E_CPU0_PE2_OCP_RX_DN5 P5E_CPU0_PE2_OCP_TX_DP5 P5E_CPU0_PE2_OCP_RX_DP5 P5E_CPU0_PE2_OCP_TX_DN6 P5E_CPU0_PE2_OCP_RX_DN6 P5E_CPU0_PE2_OCP_TX_DP6 P5E_CPU0_PE2_OCP_RX_DP6 P5E_CPU0_PE2_OCP_TX_DN7 P5E_CPU0_PE2_OCP_RX_DN7 P5E_CPU0_PE2_OCP_TX_DP7 P5E_CPU0_PE2_OCP_RX_DP7 Top Side (B Pins) Bottom Side (A Pins) FM_CPU0_OCP0_NIC_PRSTN0_N FM_CPU_OCP0_NIC_PRSTN1_N Mechanical Key P5E_CPU0_PE2_OCP_TX_DN8 P5E_CPU0_PE2_OCP_RX_DN8 P5E_CPU0_PE2_OCP_TX_DP8 P5E_CPU0_PE2_OCP_RX_DP8 P5E_CPU0_PE2_OCP_TX_DN9 P5E_CPU0_PE2_OCP_RX_DN9 P5E_CPU0_PE2_OCP_TX_DN9 P5E_CPU0_PE2_OCP_RX_DP9 P5E_CPU0_PE2_OCP_TX_DN10 P5E_CPU0_PE2_OCP_RX_DN10 P5E_CPU0_PE2_OCP_TX_DP10 P5E_CPU0_PE2_OCP_RX_DP10 P5E_CPU0_PE2_OCP_TX_DN11...
  • Page 52 P5E_CPU0_PE2_OCP_TX_DN12 P5E_CPU0_PE2_OCP_RX_DN12 P5E_CPU0_PE2_OCP_TX_DP12 P5E_CPU0_PE2_OCP_RX_DP12 P5E_CPU0_PE2_OCP_TX_DN13 P5E_CPU0_PE2_OCP_RX_DN13 P5E_CPU0_PE2_OCP_TX_DP13 P5E_CPU0_PE2_OCP_RX_DP13 P5E_CPU0_PE2_OCP_TX_DN14 P5E_CPU0_PE2_OCP_RX_DN14 P5E_CPU0_PE2_OCP_TX_DP14 P5E_CPU0_PE2_OCP_RX_DP14 P5E_CPU0_PE2_OCP_TX_DN15 P5E_CPU0_PE2_OCP_RX_DN15 P5E_CPU0_PE2_OCP_TX_DP15 P5E_CPU0_PE2_OCP_RX_DP15 FM_CPU0_PE0_OCP0_PRSTN3_QS_N USB2_OCP_NIC_DN USB2_OCP_NIC_DP FM_PWRBRK_CPU0_PE2_OCP0_ FM_CPU_PE_OCP0_NIC_PRSNTB3_N LVC3_N Other Connectors and Component...
  • Page 53 DC-SCM: DC-SCM 2.0 Edge Slot The slot links the Datacenter Secure Control Module (DC-SCM) to the motherboard, enabling centralized power, management, and security control across server hardware. This standardized interface allows easy upgrades and compatibility across various platforms. DC-SCM: DC-SCM 2.0 Edge Slot (PCIe 5.0 x1 from CPU0) OB14 OA14...
  • Page 54 Top Side (B Pins) Bottom Side (A Pins) OB11 OA11 USB2_BMC_HUB_DN OB12 OA12 USB2_BMC_HUB_DP OB13 OA13 OB14 OA14 P1V0_AUX PECI_SCM Mechanical Key CLK_66M_ESPI_CPU0_LVC18 P12V_AUX_SCM ESPI_CPU0_CS0_SCM_N P12V_AUX_SCM RST_ESPI_CPU0_LVC18_N P12V_AUX_SCM ESPI_CPU0_IO0_LVC18 P12V_AUX_SCM ESPI_CPU0_IO1_LVC18 ESPI_CPU0_IO2_LVC18 ESPI_CPU0_IO3_LVC18 IRQ_ESPI_CPU0_ALERT0_FPGA_ BMC_JTAG_LVC3_TCK LVC18_N BMC_JTAG_LVC3_TDI BMC_JTAG_LVC3_TDO BMC_JTAG_LVC3_TMS SPI_CPU0_CLK_DCSCM_LVC18_R1 SPI_CPU0_CS0_DCSCM_LVC18_R1_N FM_HPM_STBY_RST_N SPI_CPU0_IO0_DCSCM_LVC18_R1...
  • Page 55 P3V_BAT_CPU0 RST_PLD_PCIE_CPU0_DEV_PERST_N Mechanical Key P5E_CPU0_PE1_TX_DN2 P5E_CPU0_PE1_RX_DN2 P5E_CPU0_PE1_TX_DP2 P5E_CPU0_PE1_RX_DP2 HUB_SSTX4N HUB_SSRX4N HUB_SSTX4P HUB_SSRX4P BMC_TYPEA_DN CLK_100M_SCM_DN BMC_TYPEA_DP CLK_100M_SCM_DP I3C_DBG_SCM_LVC18_R_SCL I3C_SPD_SCM_R_LVC1_SCL I3C_DBG_SCM_LVC18_R_SDA I3C_SPD_SCM_R_LVC1_SDA I3C_MNG_SCM_LVC1_R_SCL Top Side (B Pins) Bottom Side (A Pins) I3C_MNG_SCM_LVC1_R_SDA Mechanical Key CLK3_50M_SCM_RMII_CLK SMB_PCIE_SCM_LVC3_R_SCL RMII3_SCM_CRS_DV_R SMB_PCIE_SCM_LVC3_R_SDA RMII3_SCM_TX_EN_R SMB_IPMB_LVC3_CLK RMII3_SCM_TXD0 SMB_IPMB_LVC3_DAT RMII3_SCM_TXD1 SMB_CPLD_UPDATE_SCM_LVC3_R_SCL RMII3_SCM_RXD0...
  • Page 56 SMB16_IPMB_LVC3_SCL SPI_CPU0_TPM_MOSI_LVC18_MUX_R1 SMB16_IPMB_LVC3_SDA SPI_CPU0_TPM_MISO_LVC18_MUX_R1 FM_SCM_PRSNT0_LVC3_N SCM_GPIO SPI_BMC_FP_CK_R SPI_IRQ_SCM_TPM_N SPI_BMC_FP_MISO_R SPI_BMC_FP_MOSI_R SPI_BMC_FP_CS0_R UART0_RX_HPM_SCM_DATA BMC_USB2A_DN BMC_USB2A_DP Other Connectors and Component...
  • Page 57 FBP_I2C_2, FBP_I2C_3: I2C Headers I2C headers are used to connect to the System Management Bus (SMBus). FBP_I2C_2-3 is for HDD backplane. P3V3_AUX BP_I2C_CLK2/BP_I2C_DAT3 FBP_I2C_2 FBP_I2C_3 BP_I2C_DAT2/BP_I2C_ DAT3 FBP_I2C_2 FBP_I2C_3 Other Connectors and Component...
  • Page 58 BAT1: CMOS Battery If the CMOS battery is out of charge, the time in the BIOS will be reset and the data of system configuration will be lost. In this case, you need to replace the CMOS battery. Replacing CMOS battery 1.
  • Page 59: Jumpers

    Jumpers ⚠ Important Avoid adjusting jumpers when the system is on; it will damage the motherboard. JTAG_SEL1 JFORCE_PWR_1 JUART_SEL_1 CMOS_CLR Default Jumper Name Description Setting 1-2: Disable force power on (Default) JFORCE_PWR_1 2-3: Enable 1-2: CPU to BMC JUART_SEL_1 2-3: UART CPLD TO CPU (Default) 1-2: BMC TO CPLD (Default) JTAG_SEL1 2-3: BMC TO CPU...
  • Page 60: Onboard Leds

    Onboard LEDs PLD_HB_LED: CPLD Heartbeat LED This LED indicates the CPLD (Complex Programmable Logic Device) status. Status Description CPLD is not activated CPLD is functioning normally Blinking PLD_HB_LED Onboard LEDs...
  • Page 61: Onboard Leds

    Onboard LEDs CPU_RST_LED: CPU Power Reset LED CPU_PWRGD_LED: CPU PowerGood LED The PWR_RST_LED display Red light on when CPU reset assert.The PWR_GD_ LED display Green light on when CPU Power is ready. CPU_ PWRGD_LED CPU_RST_LED Status Description CPU Power reset not active CPU_ RST_LED CPU reset assert CPU Power has issue...
  • Page 62: Getting Started

    Getting Started ⚠ Important All information is subject to change without prior notice. • The system photos are provided for demonstration purposes only. The • appearance and internal view of your system may vary depending on the model you purchased. Necessary Tools Anti-Static Screwdriver...
  • Page 63: System Setup

    System Setup ⚠ Important Before removing or installing any components, make sure the system is not turned on or connected to the power. System Node Removing the Server Node from the chassis ⚠ Important Power off Node first! Remove a power-on node will cause immediate power loss. ●...
  • Page 64: Drive Bay

    Drive Bay Installing 2.5" HDD/SSD 1. Carefully pull over the lever open and pull out the HDD/SSD tray . 2. With the lever open, insert the 2.5" HDD/SSD assembly vertically into the drive bay. The drive tray is not designed to be removed from the chassis. It extends just far ●...
  • Page 65: Ocp Card

    OCP Card Installing OCP Card Follow the steps below: 1. Remove the filler panel. 2. Slide the OCP card into the slot in the chassis, then push until the OCP card is connected to the connector on the system board. 3.
  • Page 66: Dc-Scm Module

    DC-SCM Module Installing DC-SCM Module Follow the steps below: 1. Slide the DC-SCM module into the slot, then puch until the module is connected to the connector on the system board. 2. Secure the DC-SCM module with the provided screw to the chassis. DC-SCM Module...
  • Page 67: System Fan

    System Fan Installing 8080 System Fan Assembly Install Fan into Fan Cage 1. With the fan aligned, place the fan securely into the fan cage. Ensure the fan’ s rubber parts are engaged with the metal hooks. ● System Fan...
  • Page 68 Secure Fan Connector 2. Align the fan connector with the designated notch, then slide the connector to the left to lock the plastic buckle onto the metal part, securing the connection. Install Fan Assembly into Chassis 3. Push the fan assembly into the chassis until it locks into place. Ensure the fan module hooks into the chassis’...
  • Page 69: Air Duct

    Air Duct The server system offers a pre-installed standard air duct available as an accessory. Installing Air Duct To install the air duct, align the pins on the front edge of the air duct with the holes on the motherboard, then lower the air duct into place until it is securely seated. Assemble two countersunk screws and secure them clockwise.
  • Page 70: Power Supply Unit (Psu)

    Power Supply Unit (PSU) The server system supports two power supplies that can be easily inserted and removed from the rear side of the system without the need for tools. ⚠ Important • Both power supplies must be identical and both power cords should be connected.
  • Page 71: Cable Routing

    Cable Routing I2C Cable(HDD BP to MB) FBP_I2C_3 6-pin to 6-pin Power Cable(HDD BP to MB) JPICPWR5 Cable Routing...
  • Page 72 MCIO 8i to MCIO 8i Cable(HDD BP to MB) JMCIO5 JMCIO6 12-pin to 12-pin Power Cable( PWR BP to MB) JPICPWR1 JPICPWR2 Cable Routing...
  • Page 73 22-pin to 22-pin Power Cable( PWR BP to MB) Cable Routing...
  • Page 74: Slide Rail

    Slide Rail & Rack Attaching the Slide Rail to a Rack 1. While pressing the release tab, firmly insert the slide rails studs into the rack’s mounting holes. 2. Release the tab and listen for a “click” to confirm secure attachment. ●...
  • Page 75 Installing the chassis into a Rack 1. With at least two people, carefully lift the chassis and align the chassis with the L-shaped shelf on the rails. 2. Slowly slide the chassis into place, ensuring even alignment on both sides. 3.
  • Page 76 MSI.COM EPS.MSI.COM...