  • Page 2: Change Description

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Change history Change description Version Release date First release. V1.0 February 2024 Added "Z: Quick order component" to  Figure 2-2 Product model. Modified section 3.3.6 Cabinet installation  and section 3.7 Basic rectifier control unit V1.1...
  • Page 3 Goodrive880-71 series is the basic rectifier unit of Goodrive880 Pro series. If not otherwise specified, the basic rectifier unit in this manual refers to the basic rectifier unit of Goodrive880 series, that is, Goodrive880-71 series product. The rated power of a single unit is 356kW–929kW, and the max. parallel power can be 5183kW.
  • Page 4: Table Of Contents

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Contents Contents 1 Safety precautions .............................1 1.1 Safety declaration ..............................1 1.2 Safety definition ..............................1 1.3 Warning symbols ..............................1 1.4 Safety guidelines ..............................2 1.4.1 Delivery and installation ..........................2 1.4.2 Commissioning and running ........................3 1.4.3 Maintenance and component replacement ....................
  • Page 5 Goodrive880 Series Basic Rectifier Unit Hardware Manual Contents 4.3.3 Wiring suggestions ............................ 36 4.3.4 Shielded cable connection ........................38 4.4 Electrical wiring ..............................39 4.4.1 Unit cable connection ..........................39 4.4.2 Isolated grid (IT grid) application ......................40 4.4.3 Screw tightening ............................40 4.4.4 Electrical installation checklist ........................
  • Page 6: Safety Precautions

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Safety precautions 1 Safety precautions 1.1 Safety declaration Read this manual carefully and follow all safety precautions before moving, installing, operating and servicing the product. Otherwise, equipment damage or physical injury or death may be caused.
  • Page 7: Safety Guidelines

    Ensure all the input power supplies have been disconnected before wiring or inspection, and wait for at least the time designated on the Goodrive880 series product or until the DC bus voltage is less than 36V. The minimum waiting time is listed in the following.
  • Page 8: Commissioning And Running

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Safety precautions 1.4.2 Commissioning and running Cut off all power supplies connected to the basic rectifier unit before terminal  wiring, and wait for at least the time designated on the basic rectifier unit after disconnecting the power supplies.
  • Page 9: Product Overview

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview 2 Product overview 2.1 Product specifications Table 2-1 Product specifications Description Specifications 380–440VAC 3PH ±10%, -15%<1min; Input voltage Rated voltage: 400V 520–690VAC 3PH ±10%, -15%<1min; Rated voltage: 690V Power input Input current For details, see section 2.3 Product ratings.
  • Page 10: Product Nameplate And Model

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview 2.2 Product nameplate and model Figure 2-1 Product nameplate IP00 Model: GD880-71-0815-6 Power(Output): 929kW Input: AC 3PH 520-690V 815A Output: DC Vin*1.35 S/N: Made in China Shenzhen INVT Electric Co.,Ltd Note: The preceding nameplate is a standard product nameplate example. The marking varies slightly depending on the model.
  • Page 11 Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview Light Heavy Heat Extern Rated value overload overload dissipa volum Model al view application application Struct tion GD880-71- A (AC) A (DC) A (DC) kVA kW(DC) A (DC) kW(DC) A (DC) kW(DC) m³/h...
  • Page 12: Overload Capability

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview The structure can be either a standard unit without a frame or a framed structure indicated by the model  suffix -K, which is applicable only for multiple D8T units in a parallel configuration. Individual D8T units do not have a framed structure.
  • Page 13: Six-Pulse Rectification

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview 2-5 shows the simplified main circuit. Figure 2-5 Simplified main circuit DC + (+) DC - (-) Name Description To protect against overload and short-circuit on the basic AC fuse rectifier unit side.
  • Page 14: Twelve-Pulse Rectification

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview demanding requirements on harmonics. Figure 2-7 shows how a single basic rectifier unit works. Figure 2-7 Simplified main circuit of a single six-pulse rectifier unit (+) (-) Name Grid transformer Breaker...
  • Page 15: Product Structure

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview Figure 2-9 Simplified main circuit of twelve-pulse rectifier units (+) (-) (+) (-) Name Phase shifting transformer Frame breaker Fuse Basic rectifier unit 2.6 Product structure The following figure shows the basic rectifier unit structure (taking GD880-71-0815-6 for example).
  • Page 16: System Configuration

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview Description Module top fixing hole Female connector, mounted and fixed to the cabinet + and - bus output copper bar Lifting hole L1/L2/L3 AC input terminal Nameplate Handle Control board user terminal...
  • Page 17: Electrical Model Selection

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview 2.8 Electrical model selection 2.8.1 Breaker A breaker can effectively prevent the overload of the variable-frequency equipment and break the fault current generated by the phase-to-phase or to-ground short circuit, and at the same time it has the function of isolation so as to avoid electric shock accidents during maintenance.
  • Page 18: Model Selection For Twelve-Pulse Rectifier Phase-Shifting Transformer

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Product overview 2.8.4 Model selection for twelve-pulse rectifier phase-shifting transformer Table 2-7 Phase-shifting transformer model selection Item Specification Remarks Winding Dy5d0 or Dy11d0 Secondary-side short circuit ≥5% impedance Secondary-side The secondary side grounding of the short circuit voltage <5%...
  • Page 19: Mechanical Installation

    Ensure all the input power supplies have been disconnected before wiring or inspection, and wait for at least the time designated on the Goodrive880 series product or until the DC bus voltage is less than 36V. 3.2 Installation environment and site Environment requirements ...
  • Page 20: Power Unit Installation Procedure

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Environment Requirement Lower than 1000 meters  When the altitude exceeds 1000m, derate by 1% for every increase of  Altitude 100m. When the altitude exceeds 2000m, consult our local dealer or office ...
  • Page 21: Unpacking

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-1 Transportation requirements Note: When transported with a forklift, the basic rectifier unit must be fixed to the pallets and transported  together, which means you are not allowed to remove the pallets to transport the unit. If the forklift's fork tines are too short, it may cause the unit/cabinet to tip over, resulting in serious injury, property damage or even death.
  • Page 22: Lifting

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-3 Unpacking Cover Sideboard 1 Rectifier unit Sideboard 2 Pallet 3.3.4 Lifting Attach the required lifting ring to the locations shown in the figure, use the sling to slowly lift the unit end, move the unit until it is completely lifted, place it vertically in the empty and flat place, and then unfold the anti-tipping stand at the lower front of the unit.
  • Page 23 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-6 Unit placing requirements >5° Note the following to fold or unfold the anti-tipping stand: Unfold the anti-tipping stand: pull down the anti-tipping stand to press the spring, wrap it around the restraining pin and rotate it 180°...
  • Page 24: Installation Space And Heat Dissipation

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation 3.3.5 Installation space and heat dissipation To ensure that the units are installed reliably and in good heat dissipation, pay attention to the following: 1. The unit must be installed and used in a cabinet.
  • Page 25: Cabinet Installation

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation 3.3.6 Cabinet installation 3.3.6.1 Cabinet requirements It is recommended that the cabinet adopts the nine-fold profile cabinet (PS cabinet). Before mounting the inverter unit, install two bottom support crossbeams, a mounting bracket, and a mounting rail in the cabinet, and design the mounting crossbeam for rectifier unit fixing, and reserve fixing holes on the mounting crossbeam (see Appendix B Dimension drawings for the specific location and size).
  • Page 26 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation 3.3.6.2 Layout and mounting for one D8T unit Figure 3-12 shows the 400mm-wide cabinet layout for one D8T rectifier unit. Figure 3-12 Cabinet layout for D8T-400 (Unit: mm) Cabinet top air outlet cover...
  • Page 27 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Name Busbar clamp support L1-phase copper busbar L2-phase copper busbar L3-phase copper busbar Copper busbar of (+) Copper busbar of (-) Fast connector female end 3.3.6.3 Layout and mounting for two D8T units Figure 3-14 shows the installation of two D8T rectifier units in a 600mm-wide cabinet.
  • Page 28 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-15 shows the installation of two D8T rectifier units in a 600mm-wide cabinet. Figure 3-15 Installation diagram of the 2*D8T-600 cabinet Name Busbar and busbar clamp Unit-top fixing assembly Unit bottom fixing plate...
  • Page 29 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation 3.3.6.4 Layout and mounting for three D8T units Figure 3-16 shows the 800mm-wide cabinet layout for three D8T rectifier units. Figure 3-16 Cabinet layout for 3*D8T-800 (Unit: mm) Cabinet top air outlet cover...
  • Page 30 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Name Busbar and busbar clamp Unit top fixing assembly (air baffle included) Unit bottom fixing plate Busbar clamp support L1-phase copper busbar L2-phase copper busbar L3-phase copper busbar Copper busbar of (+)
  • Page 31 Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-20 Pushing the basic rectifier unit into the cabinet Put your toes he re to pre vent the unit from tilting or falling Grip the handle firm ly. Fingers should n ot be out of this plane to avoid pres ure inju ries.
  • Page 32: Basic Rectifier Control Unit (Tcu) Size And Installation

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Step 4 After confirming that the rectifier unit is pushed into place, install the unit fixing screws and remove the unit entry/exit guide rail. Figure 3-22 Rectifier unit fixing 4-M8 screws for fixing 3.3.7 Basic rectifier control unit (TCU) size and installation...
  • Page 33: Installation Space

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-23 TCU dimensions (unit: mm) 72.2 17.9 99.5 70.8 3-Ø5.0 3.3.7.2 Installation space To make the TCU installation smooth, the distance between the upper and lower parts of the TCU and the...
  • Page 34: Front View

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-24 Requirements on TCU installation space (unit: mm) ≥30 ≥100 ≥50 Front view Side view 3.3.7.3 Installation procedure The TCU installation procedures are as follows: Place the TCU as shown in Figure 3-25.
  • Page 35: Keypad Installation

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation 10.3 7.25 7.25 3-∅ 4 3-M4 Note: The TCU assembly plate must be a exposed metal plate and ensure that the metal plate can be reliably  grounded. The TCU housing will be connected to the cabinet housing via a grounding plate.
  • Page 36: Fastening Torque

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Figure 3-27 Mounting the keypad bracket Sheetmetal Keypad bracket Waterproof tape Keypad 5-ø 5.0 43.5 Recommended hole size for keypad bracket installation Figure 3-28 Keypad bracket dimensions (unit: mm) 14.6 116.3 5-M4 3.3.9 Fastening torque...
  • Page 37: Checklist

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Mechanical installation Screw/Bolt Strength grade Recommended torque (N·m) 3.3.10 Checklist Operation Complete Compliant Installed the beam for basic rectifier unit fixing in the nine-fold □ □ profile cabinet. Installed the bottom tray for basic rectifier unit fixing in the □...
  • Page 38: Electrical Installation

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation 4 Electrical installation 4.1 Safety notes All safety precautions in this manual must be read and followed. Only trained and  qualified professionals are allowed to carry out the operations mentioned in this chapter.
  • Page 39: Power Cable

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation conducted interference and radiation interference. Conducted interference propagates along any conductor. Therefore, any conductor, such as wire, transmission line, inductor, and capacitor, is a transmission channel for conducted interference. Radiated interference is in the form of electromagnetic waves that propagate with energy that is inversely proportional to the square of the distance.
  • Page 40: Control Cable

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation Four-core cables can be used as input cables, but symmetrical shielded cables are recommended. Compared with four-core cables, symmetrical shielded cables can reduce electromagnetic radiation as well as the current and loss of the motor cables.
  • Page 41: Wiring Suggestions

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation Figure 4-2 Control cable Cable with multiple double-shielded twisted- Cable with multiple single-shielded pairs twisted-pairs Note: Analog signals and digital signals cannot share a same cable, and their cables must be routed separately.
  • Page 42 Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation Table 4-4 Routing sensitive and interference cables Intereference cable Sensitive cable Sensitive cable Angle of 90° Intereference cable The cable trays must be connected properly and well grounded. Aluminum trays can implement local equipotential.
  • Page 43: Shielded Cable Connection

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation 4.3.4 Shielded cable connection The shield layer of signal cable is grounded at both ends, of which the grounding points must be the same. That is, if the shield layer at the upper computer side is connected to PE, the shield layer at the drive side is also connected to PE;...
  • Page 44: Electrical Wiring

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation 4.4 Electrical wiring 4.4.1 Unit cable connection Unit terminals  Figure 4-9 Unit terminals +24E COM1 COM2 Terminal name Description Positive or negative busbar DC output Voltage: 510–650VDC 600–1035VDC Connection: copper bar terminal of M8/11N•m...
  • Page 45: Isolated Grid (It Grid) Application

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical installation 4.4.2 Isolated grid (IT grid) application When running the basic rectifier unit on an isolated grid (IT grid), the two screws on the varistor board should be removed, as shown in Figure 4-10.
  • Page 46: Basic Rectifier Control Unit (Tcu)

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) 5 Basic rectifier control unit (TCU) 5.1 Control unit components Table 5-1 Function description Symbol Component Function description Applied to 73.5 × 103 × 23.5 (mm) function expansion modules and...
  • Page 47: Status Indicator

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) Symbol Component Function description Power 24V power input terminal interface Fiber optic Master/slave fiber optic interface interface RJ45 terminal Upper computer interface, connecting to a PC for status monitoring...
  • Page 48: Control Unit Interface

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) 5.3 Control unit interface Figure 5-1 Control unit circuit wiring diagram RJ45 keypad RO3C RO3B Relay 3 output RO3A RO2C RO2B Relay 2 output RO2A RO1C RO1B Relay 1 output...
  • Page 49: External Interfaces

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) 5.3.1 External interfaces Terminal symbol Terminal name Description Input power +24E, CM Power supply for the control unit Digital input DI1–DI6, DIL Input type: relay contact, NPN or PNP...
  • Page 50: Function Description

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) Terminal Terminal Function description Cable specifications symbol 2 is short connected to 3, PW is short connected to internal +24V, and DI uses the internal power. If external power is required, you need to remove the shorting cap.
  • Page 51 Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) Terminal Terminal Function description Cable specifications symbol Two-core twisted-pair cable is AO output range: recommended. 0–20mA, Rload≤500Ω Analog Cross-sectional area: 0.5– 0–10V, Rload≥10kΩ output 2.5mm² Resolution: 11 bits + sign bit...
  • Page 52: Expansion Interfaces

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) 5.4 Expansion interfaces 5.4.1 Expansion modules By adding the corresponding expansion modules to the control unit, the desired expansion functions can be achieved. The details are as follows.
  • Page 53: Slot Expansion Application

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Basic rectifier control unit (TCU) 5.4.2 Slot expansion application The control unit can interface with various expansion modules, which are directly installed into the slots of the control unit for use. See the following figure.
  • Page 54: Maintenance And Inspection

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection 6 Maintenance and inspection 6.1 Periodical inspection 6.1.1 Overview Only trained and qualified professionals are allowed to maintain the equipment. Before you perform any maintenance on the device, you need to: Disconnect the power from the equipment (note that no switch/breaker installed in the cabinet can disconnect the power to the equipment).
  • Page 55 Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection Check scope Check item Method Criterion Visual Check temperature, inspection, and The requirements humidity, and whether there is use instruments stated in this vibration, dust, gas, oil spray, and manual are met.
  • Page 56: Replacement Of Wearing Parts

    Check whether there are foreign objects attached. For more details about maintenance, contact the local INVT office, or visit our website www.invt.com, and choose Support > Services. 6.2 Replacement of wearing parts 6.2.1 Cooling fan The service life of the cooling fan of the basic rectifier unit is more than 35000 hours. The actual service life of the cooling fan is related to the use of the unit and the temperature in the working environment.
  • Page 57: Dc Fuse

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection designated on the unit. Step 2 Remove the fan module front cover from the unit housing. Step 3 Remove the fan module connection cable. Step 4 Pull out the fan box and remove the fan with a screwdriver.
  • Page 58: Basic Rectifier Unit

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection Figure 6-2 Fuse maintenance 2. Remove the cover. 3. Disassemble the assembly of fuse and copper bar. 1. Remove the M4 screws. 6.2.3 Basic rectifier unit The unit replacement procedure is as follows: Step 1 Stop the machine and disconnect the AC power.
  • Page 59: Control Unit And Keypad

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection 6.2.4 Control unit and keypad Replace the storage card  After the control unit is replaced, the existing parameter settings can be preserved by transferring the storage card from the faulty unit to a new one.
  • Page 60 Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection OPE N Step 2 Remove the cover, press one side of the battery with a screwdriver, remove and replace the TCU module battery with a new one. Step 3 Close the cover and rotate it clockwise by 45° to tighten it.
  • Page 61 Goodrive880 Series Basic Rectifier Unit Hardware Manual Maintenance and inspection OPEN Step 2 Remove the cover, press one side of the battery with a screwdriver, remove and replace the battery with a new one. Step 3 Close the cover and rotate it clockwise by 30° to tighten it.
  • Page 62: Appendix A Technical Data

    When the altitude exceeds 1000m, derate by 1% for each increase of 100m. When the altitude exceeds 2000m, consult the local INVT dealer or office for details. The maximum operating altitude is 4000 meters.
  • Page 63: Environmental Conditions

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Technical data current at the incoming end is 100kA. Therefore, the product is applicable to scenarios where the transmitted current in the circuit is no larger than 100kA when the VFD runs at the maximum rated voltage.
  • Page 64: Ce Marking

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Technical data A.4.1 CE marking The CE marking on the product nameplate indicates that the product is CE-compliant, meeting the regulations of the European low-voltage directive (2014/35/EU) and EMC directive (2014/30/EU). A.4.2 EMC compliance declaration...
  • Page 65 Goodrive880 Series Basic Rectifier Unit Hardware Manual Technical data Basic rectifier units of category C3 cannot be applied to civilian low-voltage  common grids. When applied to such grids, the basic rectifier units may generate radio frequency electromagnetic interference. 202409 (V1.1)
  • Page 66: Appendix B Dimension Drawings

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Dimension drawings Appendix B Dimension drawings Figure B-1 D8T installation dimensions (unit: mm) Power 1275 1260 1233.9 1150.5 32.5 2-M12 (Lifting ring 373.5 187.5 installation hole) 44.0 4-M8 157.5 60.0 62.0 92.0 202409 (V1.1)
  • Page 67 Goodrive880 Series Basic Rectifier Unit Hardware Manual Dimension drawings Figure B-2 2*D8T frame installation dimensions (unit: mm) 4-∅12 4-∅11 (Anchor bolt fixing hole during transportation) 4-∅20 2- OB 12X22 (Lifting hole) Power Power (Effective overlap area of copper bars) 30 65.5 185.5...
  • Page 68 Goodrive880 Series Basic Rectifier Unit Hardware Manual Dimension drawings Figure B-4 Control unit installation dimensions (unit: mm) 72.2 17.9 99.5 70.8 3-Ø5.0 Figure B-5 Keypad installation dimensions (unit: mm) 25.8 3-M3 202409 (V1.1)
  • Page 69 Goodrive880 Series Basic Rectifier Unit Hardware Manual Dimension drawings Sheetmetal Keypad bracket Waterproof tape Keypad 4-R6 5-ø5.0 43.5 Recommended hole size for keypad bracket installation 14.6 116.3 5-M4 202409 (V1.1)
  • Page 70: Appendix C Electrical Diagram

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical diagram Appendix C Electrical diagram GD880 series basic rectifier electrical drawing 设 计 审 核 标准化 封面 设计日期 批 准 图纸名称 图 号 功 能 位 置 Designed Designed Date Checked Std.Checked Dwg.No.
  • Page 71 Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical diagram -QF1 -TA3 -TA2 -TA1 -FU11 -PE1 -PE2 -PE3 Optiona Optional -PA1 -QF3 Voltage -SA1 selection switch -QF2 -PS1 -FU13 -PG1 0-1000Vac Voltage Current measurement measurement 设 计 设计日期 审 核 标准化...
  • Page 72 Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical diagram Faul Closing Reset Closing -KA2 -SB4 -KA4 -KA5 +24E RJ45 Power supply Ethernet STO1 +24V STO2 SD card +24V RJ45 keypad interface RX/TX RX/TX DSU1 DSU2 基本整流控制单元 设 计 设计日期 审 核...
  • Page 73 Goodrive880 Series Basic Rectifier Unit Hardware Manual Electrical diagram +& +& -IU1 -IU2 设 计 设计日期 审 核 标准化 批 准 图纸名称 图 号 功 能 位 置 逆变单元 Inverter unit Designed Checked Std.Checked Function Position Designed Date Approved Dwg.Name Dwg.No.
  • Page 74: Appendix D Ordering Information

    Goodrive880 Series Basic Rectifier Unit Hardware Manual Ordering information Appendix D Ordering information Ordering Component Assembly code Structure Component code Description code quantity 400V GD880-71-0718-4 D8T rectifier unit GD880-TCU-11 Control unit SOP-880-01-EN LCD keypad L=2M(CHV-SE) 2m keypad cable 11020-00431 GD880-71-0718-4-Z...
  • Page 75 Goodrive880 Series Basic Rectifier Unit Hardware Manual Ordering information Ordering Component Assembly code Structure Component code Description code quantity 5m fiber optic HFBR-5M cable 3*D8T framed GD880-71-2734-4-K rectifier unit 2*D8T framed GD880-71-1822-4-K rectifier unit GD880-TCU-16 Control unit 11020-00437 GD880-71-4556-4-Z 5*D8T...
  • Page 76 Goodrive880 Series Basic Rectifier Unit Hardware Manual Ordering information Ordering Component Assembly code Structure Component code Description code quantity (12DF) rectifier unit GD880-TCU-13 Control unit SOP-880-01-EN LCD keypad L=2M(CHV-SE) 2m keypad cable 5m fiber optic HFBR-5M cable 3*D8T framed GD880-71-2734-4-K...
  • Page 77 Goodrive880 Series Basic Rectifier Unit Hardware Manual Ordering information Ordering Component Assembly code Structure Component code Description code quantity rectifier unit GD880-TCU-13 Control unit SOP-880-01-EN LCD keypad L=2M(CHV-SE) 2m keypad cable 3m fiber optic HFBR-3M cable 2*D8T framed GD880-71-1515-6-K rectifier unit...
  • Page 78 Goodrive880 Series Basic Rectifier Unit Hardware Manual Ordering information Ordering Component Assembly code Structure Component code Description code quantity L=2M(CHV-SE) 2m keypad cable 5m fiber optic HFBR-5M cable 2*D8T framed GD880-71-1515-6-K rectifier unit GD880-TCU-13 Control unit GD880-71-3031-6-Z 11020-00456 4*D8T SOP-880-01-EN...

This manual is also suitable for:

Gd880-71-718-4 seriesGd880-71-0980-4 seriesGd880-71-1336-4 seriesGd880-71-1822-4 seriesGd880-71-2734-4 seriesGd880-71-3645-4 series ... Show all

Table of Contents