Siemens FDE SIMATIC FDE Gateway V1.1 Equipment Manual
Siemens FDE SIMATIC FDE Gateway V1.1 Equipment Manual

Siemens FDE SIMATIC FDE Gateway V1.1 Equipment Manual

Table of Contents

Advertisement

Quick Links

SIMATIC FDE Gateway V1
FDE
SIMATIC FDE Gateway V1.1
Equipment Manual
10/2023
A5E52683268-AD
Preface
Siemens Industry Online
Support
Introduction
Overview of the technical
documentation
Installing and connecting a
device
Software and
commissioning
Certificates and approvals
Directives and declarations
Technical specifications
Dimension drawings
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDE SIMATIC FDE Gateway V1.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens FDE SIMATIC FDE Gateway V1.1

  • Page 1 SIMATIC FDE Gateway V1 Preface Siemens Industry Online Support Introduction Overview of the technical documentation SIMATIC FDE Gateway V1.1 Installing and connecting a device Software and commissioning Equipment Manual Certificates and approvals Directives and declarations Technical specifications Dimension drawings 10/2023...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Preface ..............................5 Siemens Industry Online Support ......................6 Introduction ............................7 Cybersecurity information ....................7 IT security on the northbound side ..................7 IT security on the southbound side ..................8 Personal data ........................8 Overview of the technical documentation .................... 9 SIMATIC products .........................
  • Page 4 Table of contents Connectivity settings ......................45 6.4.1 MQTT settings ........................46 6.4.2 Enable analog & digital input and digital output ..............48 6.4.3 USS settings ........................51 6.4.4 Activate Modbus TCP (X2) ....................53 6.4.5 Activating Modbus RTU (RS485) ..................55 MQTT payload examples ....................
  • Page 5: Preface

    Preface The following operating instructions contain all the required information required for commissioning and operating a device from the SIMATIC family. Basic knowledge required A prerequisite for understanding this manual is knowledge of how to use a PC. Basic knowledge of automation technology as well as IoT technologies is also recommended. Scope of this document These operating instructions apply to the SIMATIC FDE Gateway device.
  • Page 6: Siemens Industry Online Support

    For answers and solutions concerning automation technology. • mySupport Your personal working area in Industry Online Support for messages, support queries, and configurable documents. This information is provided by the Siemens Industry Online Support in the Internet (https://support.industry.siemens.com). SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 7: Introduction

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 8: Security On The Southbound Side

    Make sure to protect the southbound connection in accordance with currently recognized security guidelines. This prevents spying on the field data. More information and application notes can be found here: (https://www.siemens.com/industrialsecurity) Personal data During the configuration of the FDE gateway, it is possible to store user-specific data such as certificates, usernames, and access passwords.
  • Page 9: Overview Of The Technical Documentation

    For more documents on other hardware or specific information, please visit SIEMENS SiePortal. (https://sieportal.siemens.com/) SIMATIC products You can find an overview of the SIMATIC documentation available in Siemens Industry Online Support here: Industry Online Support International (https://support.industry.siemens.com/cs/ww/en/view/109742705)
  • Page 10 Parameter list The parameter list (https://support.industry.siemens.com/cs/ww/en/view/23708204) contains a detailed description of all parameters, ordered by function. It also contains a series of function charts as well as error and alarm messages.
  • Page 11: Sentron Products

    • SENTRON 7KM PAC5200 SENTRON 7KM PAC1020 Measuring device Equipment Manual The 7KM PAC1020 Measuring Device Manual (https://support.industry.siemens.com/cs/ww/en/view/109776608) is a condensed compilation of all required information for normal and safe operation of the PAC1020 measuring device. SENTRON 7KT PAC1200 Multi-channel current measuring system...
  • Page 12 SENTRON 7KM PAC3120 und PAC3220 Measuring device Equipment Manual The 7KM PAC3120 and PAC3220 Measuring Devices Manual (https://support.industry.siemens.com/cs/ww/en/view/109767307) is a condensed compilation of all required information for normal and safe operation of the PAC3120 and PAC3220 measuring devices. SENTRON 7KM PAC4200 Power Monitoring Device...
  • Page 13: Installing And Connecting A Device

    Information on the software license Third-party software SIMATIC FDE Gateway contains Open Source software and/or other third-party software. Copyright © SIEMENS, 2023, and licensor. All rights reserved. For more information, see the web user interface for configuring the device. SIMATIC FDE Gateway V1...
  • Page 14: Description

    Installing and connecting a device 5.3 Description Description The SIMATIC FDE Gateway is a flexible IT/OT interface for establishing connectivity for brownfield and greenfield applications. The device allows the transfer of data from the field level to an edge device or to the cloud (northbound connection). It connects: •...
  • Page 15 Installing and connecting a device 5.3 Description Functionality The device offers the following functionality: • Browser-based user interface for configuration and for viewing the device configuration • Forwarding of "southbound signals" via MQTT to northbound connectivity. Note The SIMATIC FDE Gateway cannot check the data integrity of southbound interfaces. Properties •...
  • Page 16: Main Characteristics

    Installing and connecting a device 5.4 Device design Main characteristics • Comprehensive interface set • CE conformity • Easy installation and configuration • Cloud/IoT interface (MQTT 3.1.1) – Secure MQTT via TLS – Open data format (JSON payload) • ISO degree of protection IP20 according to IEC 60529 Device design The following figure shows the design of the SIMATIC FDE Gateway, with interfaces: ①...
  • Page 17 Installing and connecting a device 5.4 Device design Pin overview of X4 connection terminal ④ The pin designations are also printed on the device. Short description Meaning Analog Input Ground analog input Ground digital input Digital input TX/A Transmission data TxD for RS232 /A for RS485 RX/B Receive data RxD for RS232...
  • Page 18: Analog Input And Digital Input/Output

    Installing and connecting a device 5.5 Analog input and digital input/output Analog input and digital input/output The device supports the following I/O functions: • Analog input (pins 1-2 of X4 plug) – 0 - 10 V DC – 0 - 20 mA or 4 - 20 mA •...
  • Page 19: Led Signaling

    Installing and connecting a device 5.6 Operating modes and LED display LED signaling The SIMATIC FDE Gateway features 10 signal LEDs visible to the user. The LED display signals the following operating modes: Designa- LED name Operating Meaning tion mode Off when the device is not switched on Operating display Green when the device is switched on...
  • Page 20: Changing The Operating Mode

    Installing and connecting a device 5.7 Changing the operating mode Changing the operating mode Use the two buttons "USER" and "RESET" or the web user interface to switch between the operating modes: Target operating mode Action From the web user interface CONFIGURATION Press and hold the USER button until the SYS LED starts to flash orange Note...
  • Page 21 Installing and connecting a device 5.8 Preparing for installation 5. If the package contents are incomplete or damaged, or do not correspond to your order, please immediately inform the responsible delivery company. WARNING Risk of electric shock and fire due to device damage A damaged device can carry dangerous voltage and trigger a fire in the machine or plant.
  • Page 22: Installing The Device

    5150-5850 vertical monopole -0.83 1.17 omni-antenna For more details, please visit SIEMENS SiePortal (https://sieportal.siemens.com/). 5.9.2 Mounting instructions • The device is only approved for operation indoors. • When installing in a control cabinet, observe the SIMATIC installation guidelines (https://support.industry.siemens.com/cs/ww/en/view/1064706) as well as the relevant DIN/VDE regulations or the respective country-specific regulations.
  • Page 23: Din-Rail Mounting

    Installing and connecting a device 5.9 Installing the device 5.9.3 DIN-rail mounting Mounting Requirement One 35 mm standard profile DIN rail is mounted at the installation location. Process 1. Place the device with the rail clamp at the marked position on the upper edge of the DIN rail. Press the device downwards.
  • Page 24 Installing and connecting a device 5.9 Installing the device Removal Process 1. Use a slotted screwdriver to pull the lower DIN rail clamp on the back of the device down to the extended position. This will release the unit from the rail. 2.
  • Page 25: Connecting The Device

    Installing and connecting a device 5.10 Connecting the device 5.10 Connecting the device 5.10.1 Notes for connecting WARNING Danger caused by lightning Lightning can enter power and data transmission cables and jump over to a person. Lightning can cause death, serious physical injury, and burns. Take the following precautionary measures: •...
  • Page 26: Connecting Interfaces To Connecting Terminal X4

    Installing and connecting a device 5.10 Connecting the device 5.10.2 Connecting interfaces to connecting terminal X4 Connection capacity Various types of interfaces can be connected to the device via the X4 terminal. The pin overview is described in the section "Design of the device (Page 16)". The following aspects must be taken into account: Conductor type Minimum cross-section...
  • Page 27: Connecting The Power Supply

    Installing and connecting a device 5.10 Connecting the device 5.10.3 Connecting the power supply The SITOP device 24 V/0.6 A (6EP3330-6SB00-0AY0) is intended for the power supply. Connect the power supply to the 14-pin X4 terminal on the front of the device. Note The device may only be connected to a 24 V DC power supply that meets the requirements for safety extra-low voltage (SELV) according to IEC/EN/DIN EN/UL 61010-1.
  • Page 28: Connecting A Device To The Rs232 Interface

    Installing and connecting a device 5.10 Connecting the device 5.10.5 Connecting a device to the RS232 interface Connect the device to pins 5-6 and 8 of the X4 terminal. You can connect a SIMATIC FDE Gateway to one of the following converters via the RS232 interface on the converter-specific module or control device: •...
  • Page 29: Wiring Example

    Installing and connecting a device 5.10 Connecting the device Wiring example The following example from the SINAMICS G120 series shows the wiring between the converter and the SIMATIC FDE Gateway. Cable shield grounding: RS232 serial cable should be shielded. The shield should be connected to functional grounding at one end of the cable at least.
  • Page 30: Connecting A Device To The Rs485 Interface

    Installing and connecting a device 5.10 Connecting the device 5.10.6 Connecting a device to the RS485 interface Connect the device to pins 5-7 of the X4 terminal. A typical PAC connection to the FDE Gateway looks like this: Note The labelling of the RS 485 device connections is not fully standardized. The "A on A and B on B"...
  • Page 31: Software And Commissioning

    Software and commissioning Establishing a connection to the device The device starts automatically as soon as power is supplied. The device configuration is carried out via the device web interface. Connect to the access point fde_gateway_xxxxxx using Wi-Fi and open the page https://192.168.4.1.
  • Page 32 Software and commissioning 6.1 Establishing a connection to the device Use the last 6 digits of the WiFi MAC address ② for the SSID: SSID = fde_gateway_[last 6 digits of the WiFi MAC address] Use the SSID with the underscores replaced by hyphens as the host name. Use the serial number ①...
  • Page 33: Downloading The Certificate

    Software and commissioning 6.1 Establishing a connection to the device Downloading the certificate 1. Click "..." in the upper bar. A popup window is displayed: 2. Select "Security". Information about the option to download the FDE-Root-CA security certificate is displayed: 3.
  • Page 34: Installing The Certificate

    Software and commissioning 6.1 Establishing a connection to the device Installing the certificate Note The installation may vary depending on the operating system or web browser. Example 1: Google Chrome / Microsoft Edge under Windows 1. Rename the downloaded certificate "FDE_Root_CA.pem" to "FDE_Root_CA.crt". 2.
  • Page 35 Software and commissioning 6.1 Establishing a connection to the device 3. Click "Install Certificate". The Certificate Import Wizard opens: SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 36 Software and commissioning 6.1 Establishing a connection to the device 4. Select "Local computer" as Storage location and click "Next". 5. Specify a Storage location for the certificate. Select "Place all certificates in the following store" and select "Trusted Root Certification Authorities": 6.
  • Page 37 7. In the last window of the Certificate Import Wizard you will see an overview of your entries. Click "Finish" to complete the installation. 8. Restart Google Chrome. Access to the FDE Gateway is then secure via https://fde.gateway.siemens.com (https://fde.gateway.siemens.com) SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 38 Software and commissioning 6.1 Establishing a connection to the device Example 2: Firefox on Windows 1. Open Settings -> "Privacy & Security" -> "View certificates"... 2. Click "Import..." and select the downloaded certificate "FDE_Root_CA.pem". SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 39 6.1 Establishing a connection to the device 3. Select the check box "Trust this CA to identify websites": The "FDEGateway_CA" entry should appear under the certificate name "Siemens". 4. Close the window with "OK". 5. Restart Firefox. Access to the FDE Gateway is then secure via https://fde.gateway.siemens.com (https://fde.gateway.siemens.com)
  • Page 40: Device Configuration

    Software and commissioning 6.2 Device configuration Device configuration Log on to the device by entering your password: The start page appears. SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 41: Start Page

    Software and commissioning 6.2 Device configuration Start page The start page provides information on the device and its current settings. ① Menu ② Information about the device ③ Operating mode setting ④ Network settings ⑤ Connectivity settings Selecting the mode and language There are three icons in the top bar of the application: Use the icon to activate Dark mode.
  • Page 42: Network Settings

    Software and commissioning 6.3 Network settings Network settings The data from the brownfield level is acquired via digital or analog input, or USS (RS232). This data is then transferred via LAN or Wi-Fi. Under Network settings, set the parameters for the two Industrial Ethernet ports and for the Wi-Fi connection.
  • Page 43 Software and commissioning 6.3 Network settings • Automatically - DHCP on: The addresses are assigned to the gateway via DHCP (Dynamic Host Configuration Protocol). – Move the switch to the "On" position. – Save the configuration by clicking the "Save" button in the upper right corner. Note The settings are only applied after a restart.
  • Page 44 Software and commissioning 6.3 Network settings Complete the settings for the Wi-Fi client. Select a Wi-Fi network with good signal strength. The connection to a cloud/Internet connection can be set. SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 45: Connectivity Settings

    Software and commissioning 6.4 Connectivity settings Connectivity settings You can set the following parameters under Connectivity: • MQTT parameters • Analog or digital input and digital output • USS parameters • Modbus TCP (X2) • Modbus RTU (RS485) SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 46: Mqtt Settings

    Software and commissioning 6.4 Connectivity settings 6.4.1 MQTT settings MQTT basic settings Open the MQTT tab. Fill in the parameters for the MQTT basic setting: • Client ID: MQTT client identifier at MQTT broker. • Publish topic name: Active apps send current values via this topic •...
  • Page 47 Software and commissioning 6.4 Connectivity settings • User name: User name that was specified in the broker • Password: Password that was specified in the broker For optional authentication of the client, you can use user name and password and/or certificates.
  • Page 48: Enable Analog & Digital Input And Digital Output

    Software and commissioning 6.4 Connectivity settings 6.4.2 Enable analog & digital input and digital output You set parameters of analog and digital input and digital output in the "Analog & digital I/O" tab. Correct wiring of inputs and the output is described in the section "Analog input and digital input/output (Page 18)".
  • Page 49 Software and commissioning 6.4 Connectivity settings Settings of the Digital_Output application via MQTT protocol A Subscribe topic name is assigned under Connectivity/MQTT. Under this topic, you can change the values of the DIGITAL_OUTPUT application, e.g.: SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 50 Software and commissioning 6.4 Connectivity settings Publish desired changes to the application DIGITAL_OUTPUT: The publish topic name must match the previously set subscribe topic name in the SIMATIC FDE Gateway. The following payload in the JSON format shows how the settings can be changed: "app": "DIGITAL_OUTPUT", "version": "1.0", "parameters": {...
  • Page 51: Uss Settings

    Software and commissioning 6.4 Connectivity settings 6.4.3 USS settings USS basic setting Enable the USS connectivity and set the parameters in the USS (RS232) tab. Adding and activating parameters To be able to save the configuration, at least one parameter must be "active" when the interface is active.
  • Page 52 Software and commissioning 6.4 Connectivity settings You can find detailed information on the available parameters, data types, numbers, and indexes for your converter in the product information. You can also select a template valid for G120 via "Select template". Note It is not possible to use RS232 and RS485 at the same time.
  • Page 53: Activate Modbus Tcp (X2)

    Software and commissioning 6.4 Connectivity settings 6.4.4 Activate Modbus TCP (X2) Modbus TCP basic settings Enable Modbus TCP connectivity and set the parameters in the Modbus TCP (X2) tab. The parameters are read out periodically. Adding and activating parameters To be able to save the configuration, at least one parameter must be "active" when the interface is active.
  • Page 54 Software and commissioning 6.4 Connectivity settings Select the data type from the drop-down menu: Enter the bit to be checked: Alternatively you can insert a template from the template list. Each template corresponds to one PAC device. Some parameters are specified as "Active" at an added template. These active parameters are generally read from a target PAC.
  • Page 55: Activating Modbus Rtu (Rs485)

    Software and commissioning 6.4 Connectivity settings 6.4.5 Activating Modbus RTU (RS485) Modbus RTU basic settings Enable Modbus RTU connectivity and set the parameters in the Modbus RTU (RS485) tab. Adding and activating parameters To be able to save the configuration, at least one parameter must be "active" when the interface is active.
  • Page 56 Software and commissioning 6.4 Connectivity settings Select the "Active" check box in the corresponding line to activate the parameter. Clear the "Active" check box in the corresponding line to deactivate the parameter. Note It is not possible to use RS232 and RS485 at the same time. It is not possible to use USS and Modbus RTU at the same time.
  • Page 57: Mqtt Payload Examples

    Software and commissioning 6.5 MQTT payload examples MQTT payload examples This section contains MQTT payload examples. Here you can see parameters which were specified in the connectivity configuration and published via MQTT. Fanout mode: One message to publish topic Example: Setting of detailed parameters "On" "app": "USS", "parameters": { "Parameter1": {...
  • Page 58 Software and commissioning 6.5 MQTT payload examples Example: Setting of detailed parameters "Off" "app": "USS", "parameters": { "Parameter1": 315.254, "STATUS": 0, "STATUS_INFO": "{}", "TIMESTAMP_MS": "1663313457709", "READOUT_MS": 35 Example: Setting - only digital input "app": "DIGITAL_INPUT", "parameters": { "SIGNAL_NAME": { "value": "digital_input_signal", "type": "string"...
  • Page 59 Software and commissioning 6.5 MQTT payload examples Explanation The value under "VALUE" corresponds to the state of the digital input: • Value: 1: Input voltage. • Value: 0: No input voltage. Example: Setting - only digital output If only the digital output is activated, the state corresponds to the published value of the DIGITAL_OUTPUT application.
  • Page 60 Software and commissioning 6.5 MQTT payload examples Example: Analog input voltage active "app": "ANALOG_INPUT", "parameters": { "SIGNAL_NAME": { "value": "analog_input_voltage", "type": "string" "RAW_VALUE": { "value": 451, "type": "uint32_t" "MA_VALUE": { "value": 0, "type": "float" "MV_VALUE": { "value": 8185.19, "type": "float" "app": "USS", "parameters": { Explanation...
  • Page 61: Basic Settings

    Software and commissioning 6.6 Basic settings Basic settings Carry out the following settings under the basic settings: • Date and time • Reset to factory settings • System upgrade • Antenna (external or internal) SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 62: Date & Time

    Software and commissioning 6.6 Basic settings 6.6.1 Date & time The time configured on the device always corresponds to UTC as the primary format. This time can be set manually or applied from the web browser: 6.6.2 Resetting to factory settings It is possible to reset the device to the factory settings.
  • Page 63: System Upgrade

    6.6 Basic settings If you forget the password, it can be reset by restoring the factory settings. To do this, use the "RESET" button. See also SiePortal (https://sieportal.siemens.com/) 6.6.3 System upgrade You can find updated software versions in the SiePortal.
  • Page 64: Antenna Settings

    Software and commissioning 6.6 Basic settings 6.6.4 Antenna settings An FDE-Wi-Fi can work either in internal or in external antenna mode. By default, the internal antenna for Wi-Fi is activated. Select the internal or external antenna in Settings: Note Changes only become effective after saving and restarting. SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...
  • Page 65: Settings For Operation On The Bfc Gateway

    (only valid for G120). • The BFC Gateway settings and installation are described in the BFCG Function Manual (https://support.industry.siemens.com/cs/us/en/view/109801700). • Middleware script must be inserted (internal mapping of the parameter values). SIMATIC FDE Gateway V1...
  • Page 66: Overview Of System Limits

    These apps offer solutions for visualizing data and machine tool-related KPIs which provide information about the production and machine states. The Siemens Industrial Edge Hub platform also offers many pre-built apps. For example, the apps "Analyze MyDrives /Edge" or "Predictive Service Analyzer - Converter" were developed for monitoring the drive train.
  • Page 67: Settings For Operation In Mindsphere

    • Generate the keys for the safe MQTT connection. Settings for operation in MindSphere The Siemens IoT-as-a-service solution MindSphere saves operating data and makes them accessible through digital applications so that you can make decisions on the basis of valuable factual information. One of these apps is the Predictive Service Assistance app, which offers access via your tenant to all relevant service and asset data of the drive systems, such as pumps and fans.
  • Page 68: Certificates And Approvals

    The device complies with the guidelines listed in the following sections. EU Declaration of Conformity The associated Declaration of Conformity is available on the Internet: EU Conformity Declaration (https://support.industry.siemens.com/cs/ww/en/view/109803135). Radio Equipment Regulations (RED) Standards ETSI EN 301489-1 (Common technical requirements)
  • Page 69: Rcm Declaration Of Conformity For Australia/New Zealand

    DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". RCM Declaration of Conformity for Australia/New Zealand FDE Gateway fulfills the requirements of the standard IEC 61000-6-4.
  • Page 70 Certificates and approvals 7.4 FCC und Canada (USA) CANADA Canadian notice This Class B digital apparatus complies with Canadian ICES-003. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Sci- ence and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference.
  • Page 71 Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ouémetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre leradiateur et votre corps. Supplier's Declaration of Conformity Unique Identifier SIEMENS, SIMATIC FDE Gateway Responsible party Siemens Industry, Inc. Digital Factory - Factory Automation...
  • Page 72: Directives And Declarations

    Directives and declarations Overvoltage category Overvoltage category II: For devices that are to be supplied via the building wiring. This applies to both pluggable and permanently connected devices. Pollution degree for electrical equipment Pollution degree 2: Usually, only non-conductive pollution occurs. Temporary conductivity due to condensation is to be expected.
  • Page 73 Directives and declarations 8.4 ESD guideline NOTICE Damage of ESD through contact Electrostatic-sensitive devices (ESDs) can be destroyed by voltages well below the threshold of human perception. If you don't discharge yourself electrostatically beforehand, just touching a component or electrical connector is sufficient to cause such voltages. The damage that occurs to a component due to overvoltage is often not immediately detectable, but may only be noticed after a longer operating time.
  • Page 74 Directives and declarations 8.4 ESD guideline NOTICE Observe grounding If no grounding is available, then no equipotentiality can be achieved. Electrostatic charges are not discharged and damage to the ESD may occur. Protect yourself against electrostatic discharging. When handling ESDs, make sure that personnel and workstations are properly grounded.
  • Page 75: Technical Specifications

    Technical specifications General technical specifications Article number 6ES7617-0BA01-0AB0 Dimensions 18 mm • Width 90 mm • Altitude 76.6 mm • Depth Weight 83.1 g Supply voltage 12/24 V • Rated value (DC) 10.2 V • Valid range low limit (DC) 28.8 V •...
  • Page 76: Digital Output

    Technical specifications 9.1 General technical specifications Digital output Number of inputs Type of digital output Open Collector Short-circuit protection Cable length (unshielded) Max. 300 m Output voltage • Type of output voltage 9.2 V • Permitted voltage at output, max. 28.0 V •...
  • Page 77 Technical specifications 9.1 General technical specifications Electromagnetic compatibility - immunity to interference Immunity with regard to conducted disturbance varia- ± 2 kV 5 kHz and 100 kHz according to IEC 61000-4-4; burst bles on the power supply cables ± 0.5 kV cable to cable according to IEC 61000-4-5; overvoltage ±...
  • Page 78: Ambient Conditions

    Technical specifications 9.2 Ambient conditions Ambient conditions Climatic ambient conditions Temperature values were have been tested according to IEC 60068-2-1, IEC 60068-2-2, and IEC 60068-2-14. Ambient air temperature -30 … 60 °C • Operation -40 … 70 °C • Transport/storage Gradient Max.
  • Page 79: Dimensional Drawing Of The Device

    Dimension drawings Dimension drawings Dimensional drawing of the device All dimensions are in mm. Dimension drawing of the 14-pin X4 terminal The grid dimension is 2.54 mm. All dimensions are in mm. SIMATIC FDE Gateway V1 Equipment Manual, 10/2023, A5E52683268-AD...