COMPATIBILITY
This acoustic device is only compatible with conventional control panels and systems, unless an approved optional module is fitted. For more
specific information regarding compatibility refer to your fire security system supplier and the technical documentation concerning the control
panel in use.
The VdS approvals for products CWS100, CWS100(W), CWS100-AV, CWS100-AV(W) is only valid in combination with the
ALWS-MOD module. The ALWS-MOD is mentioned in the appendix of the respective approvals. If the sirens are combined
with another module, the VdS approvals expires. The devices are only VdS approved to Type A (indoor application).
INSTALLATION - IMPORTANT NOTES
Refer to national and international standards in use for spacing and positioning of the fire security's system devices; refer also to specific
standards and your supplier if the system is going to be installed in particular environments or environments where specific risks exist.
This device is to be used only with conventional control panels and systems (check the COMPATIBILITY paragraph).
This device must be wired according to the connection details described in this manual.
Disconnect the sounder line from the control panel before installing this device.
Test the device after installation.
SOUNDER OPENING PROCEDURE
In order to detach the upper sounder body from the base:
1) Insert the pins of the compatible key into the holes of one of the two side locking mechanisms.
2) Turn the key 90° to the left whilst applying light pressure.
3) Repeat this step for the second side locking mechanism; the locking mechanism appears as in picture 1 when
in the open position (flush).
4) Detach the sounder body from the base by pulling gently to separate (picture 3).
SOUNDER CLOSING PROCEDURE
In order to assemble the sounder body to the base:
1) Assemble the sounder body to the base using gentle pressure (picture 3).
2) Insert the pins of the compatible key into the holes of one of the two side locking mechanisms.
3) Turn the key 90° to the right.
4) Repeat this step for the second side locking mechanism, starting from point 2; the locking
mechanism appears as in picture 2 once closed (recessed).
5) To secure use the retaining screws, using the location holes on both sides of the base (picture 4).
ARGUS SECURITY S.R.L. - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy
CWS100(W)
CONVENTIONAL WALL SOUNDER
Picture 3
Picture 4
928w/07
G225023
Picture 1
Picture 2
www.argussecurity.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CWS100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Argus Security CWS100

  • Page 1 The VdS approvals for products CWS100, CWS100(W), CWS100-AV, CWS100-AV(W) is only valid in combination with the ALWS-MOD module. The ALWS-MOD is mentioned in the appendix of the respective approvals. If the sirens are combined with another module, the VdS approvals expires.
  • Page 2: Wall Installation

    EN 54-3 Type B - approved for outdoor use. The devices are only VdS approved to Type A (indoor application). OUTDOORS AND DAMP ENVIRONMENTS INSTALLATION When installing the sounder outdoors or in a damp environment, carefully apply the self-adhesive sealing pad to the back of the sounder base (picture 5). WALL INSTALLATION Picture 5 1) Choose the installation location for the sounder based upon system design regulations.
  • Page 3 Use of the Tone or Alt terminals enable, respectively, the main tone set or the alternate one; refer to the MAIN TONE SET and the ALTERNATE TONE SET paragraphs. Picture 11 Sounder line (+) Sounder line (-) ARGUS SECURITY S.R.L. - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy www.argussecurity.it...
  • Page 4 OUTPUT TONE SETTING Use the DIP switch on the back of the sounder body to select the tone required; for this function the first five switches are used, highlighted in picture 12. Picture 12 The switches positioned upwards acquire value “1”; on the other hand, if positioned downwards acquire value “0”. 1) From the MAIN TONE SET table or the ALTERNATE TONE SET table (the choice of the table depends on how the sounder’s wiring has been carried out) select the output alarm tone triggered when the sounder is activated.
  • Page 5 (2900Hz for 500ms ON, 500ms OFF) x3, then 1500ms OFF 00011 LF Sweep (Cranford tone) 800-1000Hz swept every 500ms (2Hz) 10000 Table 3 * EN 54-3 certified tones ARGUS SECURITY S.R.L. - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy www.argussecurity.it...
  • Page 6 ALTERNATE TONE SET Tone DIP switch configuration: Tone description number 1, 2, 3, 4 and 5 800Hz continuous 11101 1000Hz continuous tone 01011 500-1200Hz for 3500ms, then off for 500ms 10101 800Hz continuous 00111 2400Hz continuous 10010 800Hz continuous 11110 500Hz continuous 11100 500Hz continuous...
  • Page 7: Technical Specifications

    * Consult the latest version of the TDS-CWSXX document for IP rating (EN 54-3 certified) further information, obtainable from your supplier. ACOUSTIC OPERATIONAL PERFORMANCE Picture 14 ARGUS SECURITY S.R.L. - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy www.argussecurity.it...
  • Page 8: Warnings And Limitations

    CO5010UK and the fire location and may be affected by special environmental conditions. Refer to and follow national codes of practice and other internationally recognized fire engineering ARGUS SECURITY S.R.L. standards. Via del Canneto, 14 Appropriate risk assessment should be carried out initially to determine correct design criteria and 34015 Muggia (TS) updated periodically.

This manual is also suitable for:

Cws100w

Table of Contents