SOLIS S6 Series User Manual
SOLIS S6 Series User Manual

SOLIS S6 Series User Manual

Hybrid inverter single phase system
Hide thumbs Also See for S6 Series:

Advertisement

Quick Links

User Manual
for S6 Series Hybrid Inverter
Applicable models
S6-EH1P3K-L-PLUS-AU
S6-EH1P3.6K-L-PLUS-AU
S6-EH1P5K-L-PLUS-AU
S6-EH1P6K-L-PLUS-AU
S6-EH1P8K-L-PLUS-AU
Applicable System
Single phase system
Version 1.0, Release Date: 07,2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S6 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SOLIS S6 Series

  • Page 1 User Manual for S6 Series Hybrid Inverter Applicable models S6-EH1P3K-L-PLUS-AU S6-EH1P3.6K-L-PLUS-AU S6-EH1P5K-L-PLUS-AU S6-EH1P6K-L-PLUS-AU S6-EH1P8K-L-PLUS-AU Applicable System Single phase system Version 1.0, Release Date: 07,2024...
  • Page 2: Important Notes

    Every attempt has been made to make this document complete, accurate and up-to-date. Individuals reviewing this document and installers or service personnel are cautioned, however, that Solis reserves the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages...
  • Page 3: Table Of Contents

    Contents 1. Introduction 01-04 ……………………………………………………………………………………………………………………………… 1.1 Product Overview ……………………………………………………………………………………………………………… 1.2 Inverter Wire Box and Connection Points ………………………………………………………………… 1.3 Product Features ………………………………………………………………………………………………………………… 1.4 Packaging ……………………………………………………………………………………………………………………………… 1.5 Tools Required for Installation ……………………………………………………………………………………… 2. Safety & Warning 05-07 …………………………………………………………………………………………………………… 2.1 Safety ……………………………………………………………………………………………………………………………………… 2.2 General Safety Instructions ……………………………………………………………………………………………...
  • Page 4 Contents 6. Maintenance ………………………………………………………………………………………………………………………… 6.1 Smart O&M …………………………………………………………………………………………………………………………… 7. Troubleshooting ………………………………………………………………………………………………………………… 8. Specifications ……………………………………………………………………………………………………………………… 9. Appendix ……………………………………………………………………………………………………………………………………...
  • Page 5: Introduction

    User Manual 1.1 Product Overview The Solis S6-EH1P(3-8)K-L-PLUS-AU series is designed for residential hybrid systems. The inverter can work with low-voltage lithium ion and Lead-acid batteries to maximize self-consumption and provide backup power if the grid fails and there is not enough PV power to cover load demand.
  • Page 6: Inverter Wire Box And Connection Points

    8. PV Module Input Conduit for Battery conductors should be connected here 9. Battery Connection 10. COM Port Solis data logger gets connected here-only USB version of the loggers will work 11. Antenna Extends the range of the inverter Bluetooth signal(for system commissiong...
  • Page 7: Product Features

    1. Introduction User Manual 1.3 Product Features Highly Flexible Integrated 2 MPPTs with 2(3-6K)/3(8K) strings, suitable for residential rooftop installations with multiple array orientations. Compatible with multiple brands of battery models giving customers multiple battery options. Exquisite LED Indicators with built in Bluetooth to provide local operation without Internet.
  • Page 8: Packaging

    Quick Installation Manual Bluetooth ntenna x1 Quick Installation Manual x1 If anything is missing, please contact your local Solis distributor. 1.5 Tools Required for Installation Torqx T20 Screwdriver Wire Strippers 12AWG to 6AWG Wire Strippers 20AWG to 10AWG Crimping Tool...
  • Page 9: Safety And Warning

    2. Safety & Warning User Manual 2.1 Safety The following types of safety instructions and general information appear in this document as described below: DANGER “Danger” indicates a hazardous situation which if not avoided, will result in death or serious injury. WARNING “Warning”...
  • Page 10 NEC Article 690, Part II. All Solis single phase inverters feature an integrated DC disconnect switch. CAUTION Risk of electric shock, do not remove the cover. There are no serviceable parts inside, refer servicing to qualified and accredited service technicians.
  • Page 11: Notice For Use

    2. Safety & Warning User Manual 2.3 Notice for Use The inverter has been constructed according to he applicable safety and technical guidelines, use the inverter in installations that meet the following specifications only: 1. Permanent installation is required. 2. The electrical installation must be compliant with all local and national regulations & standards.
  • Page 12: Installation

    3. Installation User Manual 3.1 Select a Location to Install the Inverter When selecting a location for the inverter, the following criteria should be considered: Exposure to direct sunlight may cause output power derating due to overheating It is recommended to avoid installing the inverter in direct sunlight. The ideal location is one where the ambient temperature does not exceed 40°C.
  • Page 13 Consult the technical specifications sections at the end of this manual for additional environmental condition requirements (temperature range, altitude, etc.) 3.1.3 Angle of installation This model of Solis inverter must be mounted vertically (90 degrees or backwards less than or equal to 15 degrees from 90 degrees straight up).
  • Page 14: Product Handling

    3. Installation User Manual 3.1.4 Avoiding direct sunlight Installation of the inverter in a location exposed to direct sunlight should to be avoided. Direct exposure to sunlight could cause: Power output limitation (with a resulting decreased energy production by the system). Premature wear of the electrical/electromechanical components.
  • Page 15: Mounting The Inverter

    3. Installation User Manual 3.3 Mounting the Inverter Mount the inverter on a wall or structure capable of bearing the weight of the machine. The inverter must be mounted vertically with a maximum incline of +/- 5 degree. Exceeding this may cause the output power to derate. To avoid overheating, always make sure the flow of air around the inverter is not blocked.
  • Page 16 3. Installation User Manual Dimensions of mounting bracket: 407.5 unit:mm (3-6)K is 358 Φ6.8 8k is 360 Φ2 Only 8K has this hole, and this hole cannot be blocked 3-OB11*6.8 Figure 3.6 Inverter wall mounting Once a suitable location has be found accordingly to 3.1 using figure 3.6 mount the wall bracket to the wall.
  • Page 17: Inverter Wiring Overview

    Data Logger Monitoring of the system (For more details, please refer to the on SolisCloud (Optional) Solis data logger product manual) NOTE Conductor dimensions and OCPD sizing to be determined in accordance with the national electrical code (NEC) and local standards.
  • Page 18: Ground Cable Installation

    3. Installation User Manual 3.5 Ground Cable Installation An external ground connection is provided at the right side of inverter. Prepare OT terminals: M4. Use proper tooling to crimp the lug to the terminal. Connect the OT terminal with ground cable to the right side of inverter. The torque is 2N.m. M4 Screw removed Torque: 2N.m Earth wire...
  • Page 19: Pv Cable Installation

    3. Installation User Manual 3.6 PV Cable Installation Before connecting inverter, please make sure the PV array open circuit voltage is within the limit of the inverter. Before connection, please make sure PV array is grounded. Before connection, please make sure the polarity of the output voltage of PV array matches the“DC+”and“DC-”symbols.
  • Page 20 3. Installation User Manual 3. Pass the stripped DC cable through the nut and waterproof rubber ring. Positive terminal Negative terminal Figure 3.12 4. Connect the wire part of the DC cable to the metal DC terminal and crimp it with a special DC terminal crimping tool.
  • Page 21 3. Installation User Manual 6. Measure PV voltage of DC input with multimeter, verify DC input cable polarity. Figure 3.15 7. Connect the wired DC terminal to the inverter as shown in the figure, and a slight "click" is heard to prove the connection is correct. Click Figure 3.16 CAUTION:...
  • Page 22: Battery Cable Installation

    Figure 3.17 Battery cable connection NOTE The battery fuse in the inverter wire box is replaceable. The replacement can only be done by a technician authorized by Solis. Fuse specification: 70V 350A for 8K, 70V 200A for (3-6)K. NOTE Before connecting the battery, please carefully read the product manual of the battery and perform the installation exactly as the battery manufacturer specifies in the manual.
  • Page 23: Ac Wiring

    3. Installation User Manual 3.8 AC Wiring DANGER Before installing the AC cables, be sure that the OCPDs (breakers) are turned off. Use a multimeter to verify that the AC voltages are 0Vac before proceeding. There are three sets of AC output terminals and the installation steps for both are the same. Backup GRID Figure 3.18 AC output terminals...
  • Page 24: Meter/Ct Connection

    3. Installation User Manual 3.9 Meter/CT Connection CAUTION: Make sure the AC cable is totally isolated from AC power before connecting the smart meter or CT. 3.9.1 Meter Installation The smart meter provided in the product box can be used to measure import/export power and it is required for the export limit control.
  • Page 25 3. Installation User Manual 3.9.2 CT Installation(optional) If CT is preferred to be installed other than the provided smart meter, please contact Solis sales rep to order the CT. CT Model: ESCT-TA16-100A/50mA CT Cable: Size – 2.3mm2, Length - 1m Please install the CT on the hot line at the system grid connection point and the arrow on the CT needs to point to the grid direction.
  • Page 26: Inverter Communication

    User Manual 3.10 Inverter Communication 3.10.1 Communication Ports Port Port Type Description Used for Solis data logger connection Used for Antenna connection for built in ANTENNA Antenna Bluetooth signal 4 hole watertight cable gland Used for RJ45 connection inside wiring box...
  • Page 27 3. Installation User Manual 3.10.2 Communication Terminals METER RS485 ATS240V HM G-V G-S G-D1 Figure 3.21 Communication terminals Terminal Type Description Used for CAN communication between inverter and Lithium battery BMS. Used for Battery temperature sensor between RJ45 inverter and lead-acid battery. (Optional)Used for RS485 communication between inverter Meter RJ45...
  • Page 28 When Lead-acid battery is used, battery temperature sensor needs to be connected to the BMS terminal of the inverter. Please contact Solis sales rep to order battery temperature sensor. Step 1. Take out the battery temperature sensor cable and lead through the COM1 or COM2 port of the inverter and connect the RJ45 connector to the BMS terminal.
  • Page 29 User Manual 3.10.4 Meter Terminal Connection (Optional) If a smart meter is preferred to be installed other than the provided CT, please contact Solis sales rep to order the smart meter and corresponding meter CT. Please lead the Meter RS485 cable through the COM1 or COM2 port of the inverter and connect to the Meter terminal with RJ45 connector.
  • Page 30 3.10.5 DRM Port Connection (Optional) 3.10.5.1 For Remote Shutdown Function Solis inverters support remote shutdown function to remotely control the inverter to power on and off through logic signals. The DRM port is provided with an RJ45 terminal and its Pin5 and Pin6 can be used for remote shutdown function.
  • Page 31 If a 3rd party external device or controller needs to communicate with the inverter, the RS485 port can be used. Modbus RTU protocol is supported by Solis inverters. To acquire latest protocol document, please contact Solis local service team or Solis sales. NOTE:...
  • Page 32 3. Installation User Manual 3.10.8 12-pin Communication Terminal Block Terminal Block Connection Steps: Step 1. Lead the wires through the hole in COM3 port (Hole Diameter: 2 mm) Step 2. Strip the wires for 9mm length Step 3. Use slot type screwdriver to press the block on the top Step 4.
  • Page 33 3. Installation User Manual 3.10.8.2 G-V Terminal Connection The G-V terminal is a voltage-free dry contact signal for connecting with generator's NO relay to start up the generator when necessary. When generator operation is not needed, Pin3 and Pin4 is in open circuit. When generator operation is needed, Pin3 and Pin4 is in short circuit.
  • Page 34: Diesel Generator Wiring

    3. Installation User Manual 3.11 Diesel Generator Wiring...
  • Page 35: Parallel System Wiring

    3. Installation User Manual...
  • Page 36: Inverter Remote Monitoring Connection

    3.13 Inverter Remote Monitoring Connection The inverter can be remotely monitored via WiFi, LAN or 4G. The USB type COM port at the bottom of the inverter can connect to different kinds of Solis data loggers to realize the remote monitoring on Soliscloud platform.
  • Page 37: External Residual Current Device(Rcd)

    All series of Solis inverters are integrated with an internal residual current device to protect against any potential d.c component and a.c component of residual current. Therefore, all Solis inverters, due to the design, are not able to feed in DC fault current to the system which fully complies with IEC60364-7-712.
  • Page 38: Overview

    User Manual 4.1 Intelligent LED Indicators There are five indicators on the The Solis S6-EH1P(3-8)K-L-PLUS-AU Series Inverter(Battery,Power, WiFi.Ethernet and Bluetooth)which indicate the working status of the inverter. The Bluetooth Antenna or WiFi data logger shall be installed at the Antenna/COM port of the hybrid inverter before local debugging.
  • Page 39: Password Reset

    4. Overview User Manual 4.2 Password Reset When the password of the owner or the installer needs to be reset,please long press the Inverter indicator for 5s. If the reset command is successfully triggered,the status indicator will be blue and blink for 3s at the frequency of 0.5s, then restore the original state of the indicator.
  • Page 40: Commissioning

    5. Commissioning User Manual 5.1 Pre-Commissioning ● Make sure that no high voltage conductors are energized. ● Check all conduit and cable connection points ensure they are tight. ● Verify that all system components have adequate space for ventilation. ● Follow each cable to ensure that they are all terminated in the proper places. ●...
  • Page 41: Log In The App Via Bluetooth

    5. Commissioning User Manual 5.4 Log in the APP via Bluetooth Step 1: Connect with Bluetooth. Turn on Bluetooth switch on your mobile phone and then open the Soliscloud APP. Click “More Tools”->”Local Operation”->”Connect with Bluetooth” < Local Operation Register Register Hello, Hello,...
  • Page 42: Initial Set Up

    5. Commissioning User Manual 5.5 Initial set up If this is the first time the inverter has been commissioned, you will need to first go through the Quick Settings.Once this has been done,these settings can be changed later. Inverter Time -> Battery Model -> Meter Setting -> Grid Code -> Work mode A.
  • Page 43 5. Commissioning User Manual C. Meter Setting: Set both the Meter Type and the Meter Location. It is suggested to install the meter at the system grid connection point and select “Meter in Grid”.If there is no meter connected for the moment, please select”No Meter” to avoid alarms. Quick Setting Next Battery Model...
  • Page 44 5. Commissioning User Manual Self-Use Mode stores the excess PV power into the battery. If the battery is charged, or there is no battery, the excess PV power will be exported(sold)back to the utility company. If the system is set to not export any power, then the inverter will curtail the PV power(derate the inverter output power).
  • Page 45 5. Commissioning User Manual Backup Mode can be opened in the Self-Use or Feed in Priority Mode. What this mode does is ensure that the battery does not drain past the Reserve SOC(state-of-charge) percentage. The battery will cycle between 100% and the Reserve SOC, so if grid power is lost, the battery will have the Reserve SOC at the very least to carry the home through the outage.
  • Page 46: App Interface

    5. Commissioning User Manual 5.6 APP Interface 5.6.1 APP Interface Structure Today Yield of PV Today Charge&Discharge of Battery Today Imported&Emported of Grid Home Time of Use Today Consumption of Load Self-Use Backup Mode GEN Energy Work Mode Time of Use Feed in Priority PV Energy Backup Mode...
  • Page 47 5. Commissioning User Manual 5.6.2 Home The home page can display the working state, Today Yield of PV, Today Imported/Exported of Grid, Today Charged/Discharged of Battery ,Today Consumption of household electricity and Today GEN yield. At the bottom of page are four submenus: Home, Info, Alarm and Settings. Today imported:0.0KWh Today Today Yield:00.0KWh...
  • Page 48 5. Commissioning User Manual 5.6.3 Information The Info page breaks down into four categories: Inverter, Battery, Grid, and Load. Inverter: inverter power production history, PV voltages and currents, inverter information (serial number, model number, and firmware version),grid code, and alarm code history. There are two additional information in the inverter page: GEN Information: generator power, today and total generator yield, and warning information.
  • Page 49 5. Commissioning User Manual 5.6.4 Alarm The alarm page can display the current alarm and the historical alarm. Solis-3115022B100041 Solis-3115022B100041 < < Update:15:28:46 Update:15:28:46 Current Alarm Historical Alarm Current Alarm Historical Alarm HeartbeatLose Alarm Message: Alarm Message: HeartbeatLose 1065 Alarm Code:...
  • Page 50 5. Commissioning User Manual Force-charge SOC: Due to the battery power consumption, when the over-discharge SOC drops to the force-charge SOC, the inverter will directly charge the battery according to the maximum battery charging current until the battery SOC reaches the over-discharge SOC. (The charging power is nor limited to sources, which may be from PV or from the grid.
  • Page 51 5. Commissioning User Manual Meter/CT Setting You can select meter or CT for system measurement. Meter Type: Please select a correct type. The wrong option may cause the meter RS485 communication Failed. If the battery and meter are not connected, please select the “NO Meter”...
  • Page 52 5. Commissioning User Manual Backup Setting Backup Voltage Setting: This is the voltage designated to the backup loads in the event of a grid power loss. Backup Setting Backup Port Enabling Setting Backup Port Reference Voltage Setting 230.0V > Voltage Droop Setting Generator Setting With Generator: Please turn it on if the generator is ready to work.
  • Page 53 The inverter commissioning process has now been completed. It is recommended to monitor the system closely over the next week to ensure that everything is working as it should. Please refer to the Solis data logger manual for assistance with registering a new plant on SolisCloud.
  • Page 54: Maintenance

    6. Maintenance User Manual Solis S6 Series inverter does not require any regular maintenance. However, cleaning the heatsink will help the inverter dissipate heat and increase the lifetime of inverter. The dirt on the inverter can be cleaned with a soft brush.
  • Page 55: Troubleshooting

    7. Troubleshooting User Manual Message Name Information Description Troubleshooting Suggestion 1. Turn on the device in the ON/OFF Setting. Control device to shutdown 1. Confirm whether the inverter is connected to an external EPM/meter to prevent reverse current. 2. Confirm whether the inverter is controlled The device's output is under LmtByEPM by an external third-party device.
  • Page 56 7. Troubleshooting User Manual Message Name Information Description Troubleshooting Suggestion 1. Grid side fault, restart the device. Surge Alarm On-site grid surge If it is still not eliminated, please contact the manufacturer's customer service. Grid voltage exceeds the OV-G-V01 upper voltage range Grid voltage exceeds the UN-G-V01 lower voltage range...
  • Page 57 7. Troubleshooting User Manual Message Name Information Description Troubleshooting Suggestion 1. Confirm whether the battery model selection Wrong battery brand selection BatName-FAIL is consistent with the actual one. 1. Can failure is a failure of communication between inverter and battery. Check cable conditions.
  • Page 58 7. Troubleshooting User Manual Message Name Information Description Troubleshooting Suggestion 1. Confirm that the grid is abnormal. 2. Confirm that the AC cable connection is not DCInj-FAULT The current DC component abnormal. (1037 DATA:0000) exceeds the limit 3. Restart the system, confirm that the fault continues.
  • Page 59 Please keep ready with you the following information before contacting us. 1. Serial number of Solis Singles Phase Inverter; 2. The distributor/dealer of Solis Singles Phase Inverter (if available); 3. Installation date. 4. The description of the problem together with necessary information, pictures, attachment.
  • Page 60: Specifications

    8. Specifications User Manual Technical Data S6-EH1P3K-L-PLUS-AU S6-EH1P3.6K-L-PLUS-AU Input DC (PV side) Recommended Max PV array size 6000W 7200W Max Usable PV Input Power 4800W 5760W Max. input voltage 500V Rated voltage 330V Start-up voltage MPPT voltage range 90-435V Full load MPPT voltage range 150-435V 180-435V Max.
  • Page 61 8. Specifications User Manual Technical Data S6-EH1P3K-L-PLUS-AU S6-EH1P3.6K-L-PLUS-AU Input AC (Grid side and Gen side) Input voltage range 187-253V Max./Rated input current 20.0 A 24.0 A Frequency range 45-55 Hz Output AC(Back-up) Rated output power 3.6kW Max. output power 3.6kW Max.
  • Page 62 8. Specifications User Manual Technical Data S6-EH1P3K-L-PLUS-AU S6-EH1P3.6K-L-PLUS-AU General data Dimensions(W/H/D) 335*560*227mm Weight 22kg Topology Transformerless Operation temperature range -40℃~+60℃ Ingress protection IP66 Cooling concept Natural convection Environmental category Indoor and outdoor Relative humidity range 0-95% Pollution degre Max.operation altitude 4000m Grid connection standard AS 4777...
  • Page 63 8. Specifications User Manual Technical Data S6-EH1P5K-L-PLUS-AU S6-EH1P6K-L-PLUS-AU Input DC (PV side) Recommended Max PV array size 10000W 12000W Max Usable PV Input Power 8000W 9600W Max. input voltage 500V Rated voltage 330V Start-up voltage MPPT voltage range 90-435V Full load MPPT voltage range 250-435V 300-435V Max.
  • Page 64 8. Specifications User Manual Technical Data S6-EH1P5K-L-PLUS-AU S6-EH1P6K-L-PLUS-AU Input AC (Grid side and Gen side) Input voltage range 187-253V Max./Rated input current 31.0 A 39.0 A Frequency range 45-55 Hz Output AC(Back-up) Rated output power Max. output power Max. apparent output power 2 times of rated power, 10 S Back-up switch time <4ms...
  • Page 65 8. Specifications User Manual Technical Data S6-EH1P5K-L-PLUS-AU S6-EH1P6K-L-PLUS-AU General data Dimensions(W/H/D) 335*560*227mm Weight 22kg Topology Transformerless Operation temperature range -40℃~+60℃ Ingress protection IP66 Cooling concept Intellgent cooling Environmental category Indoor and outdoor Relative humidity range 0-95% Pollution degre Max.operation altitude 4000m Grid connection standard AS 4777...
  • Page 66 8. Specifications User Manual Technical Data S6-EH1P8K-L-PLUS-AU Input DC (PV side) Recommended Max PV array size 16000W Max Usable PV Input Power 12800W Max. input voltage 500V Rated voltage 330V Start-up voltage MPPT voltage range 90-435V Full load MPPT voltage range 200-435V Max.
  • Page 67 8. Specifications User Manual Technical Data S6-EH1P8K-L-PLUS-AU Input AC (Grid side and Gen side) Input voltage range 187-253V Max./Rated input current 50.0 A Frequency range 45-55 Hz Output AC(Back-up) Rated output power Max. output power Max. apparent output power 2 times of rated power, 10 S Back-up switch time <4ms Rated output voltage...
  • Page 68 8. Specifications User Manual Technical Data S6-EH1P8K-L-PLUS-AU General data Dimensions(W/H/D) 335*560*227mm Weight 22.5kg Topology Transformerless Operation temperature range -40℃~+60℃ Ingress protection IP66 Cooling concept Intellgent cooling Environmental category Indoor and outdoor Relative humidity range 0-95% Pollution degre Max.operation altitude 4000m Grid connection standard AS 4777 Safty/EMC standard...
  • Page 69: Appendix

    A: OV-ILLC indicates there is an overcurrent issue on the internal LLC circuit. It could be transient status during extreme condition such as overload. If it happens constantly or too frequent and the extreme conditions have been excluded, please contact Solis service team. Q6: Why I have "OV-BATT-H" Alarm on the inverter ? A: OV-BATT-H indicates over voltage issue on the hardware of battery circuit.
  • Page 70 9. Appendix User Manual 9.1 Built-In DC Isolator Specification A DC-PV2 switch, complied to As60947. 3: 2018, within the inverter, is used as isolating device. Please check below ratings. (For S6-EH1P(3-6)K-L-PLUS-AU) DC switch brand SVRUI Model GHX5-32P PV category DC-PV2 1100V 1500V Uimp...
  • Page 71 9. Appendix User Manual 9.2 Australian Grid Code Settings Customers can follow the quick setting process to select the corresponding grid codes based on AS/NZS4777.2:2020 (4777-A/ 4777-B/ 4777-C/ 4777-N). Or modify the grid code in following path in the APP: Settings -> Grid Code Setting NOTE: The standard code selection “4777-A”, “4777-B”, “4777-C”...
  • Page 72 9. Appendix User Manual 9.2.1 Working Mode Set Solis AU version inverters have the following working mode settings: 1. Null 2. Volt-Watt 3. Volt-Var 4. Fixed PF 5. Fixed Reactive The setting path in the APP is: Settings-> Inverter Parameter Setting ->...
  • Page 73 9. Appendix User Manual 3. Volt-Var Supplying Absorbing Inverter Voltage, V Voltage 1 (Vv1): 180-230V (Default: 4777-A(207V); 4777-B(205V);4777-C(215V);4777-N(207V)) Voltage 2(Vv2) : 180-230V (Default: 4777-A(220V); 4777-B(220V);4777-C(230V);4777-N(220V)) Voltage 3(Vv3) : 230-265V (Default: 4777-A(240V); 4777-B(235V);4777-C(240V);4777-N(235V)) Voltage 4(Vv4) : 230-265V (Default: 4777-A(258V); 4777-B(255V);4777-C(255V);4777-N(244V)) Leading(Supplying) : +30~+60% (Default: 4777-A(+44%);...
  • Page 74 9. Appendix User Manual 4. Fixed PF Description: This mode is to set a fixed power factor output Range: -0.8~+0.8 Default: 1 5. Fixed Reactive Description: This mode is to set a fixed reactive power output Range:-60%~+60% Default: 0% 9.2.2 Power Rate Limit Settings->...
  • Page 75 Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China. Tel: +86 (0)574 6578 1806 Fax: +86 (0)574 6578 1606 Please adhere to the actual products in case of any discrepancies in this user manual. If you encounter any problem on the inverter, please find out the inverter S/N and contact us, we will try to respond to your question ASAP.

This manual is also suitable for:

S6-eh1p3k-l-plus-auS6-eh1p3.6k-l-plus-auS6-eh1p5k-l-plus-auS6-eh1p6k-l-plus-auS6-eh1p8k-l-plus-au