SOLIS S6-GR1P K-M Series Installation And Operation Manual

SOLIS S6-GR1P K-M Series Installation And Operation Manual

Mini single phase inverter
Hide thumbs Also See for S6-GR1P K-M Series:

Advertisement

Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
Please adhere to the actual products in case of any discrepancies in this user manual.
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Solis S6
Mini Single
Installation and Operation Manual
S6-GR1P(0.7-3.6)K-M
Ginlong Technologies Co., Ltd.
Phase Inverter
Ver 1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S6-GR1P K-M Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOLIS S6-GR1P K-M Series

  • Page 1 Solis S6 Mini Single Phase Inverter Installation and Operation Manual S6-GR1P(0.7-3.6)K-M Ver 1.3 Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China. Tel: +86 (0)574 6578 1806 Fax: +86 (0)574 6578 1606 Please adhere to the actual products in case of any discrepancies in this user manual.
  • Page 2: Table Of Contents

    Contents 1. Introduction …………………………………………………………………………………………………………………………… 1.1 Product Description ………………………………………………………………………………………………………… 1.2 Packaging ………………………………………………………………………………………………………………………… 1.3 Product Storage ………………………………………………………………………………………………………………………… 2. Safety Instructions …………………………………………………………………………………………………………… 2.1 Safety Symbols ………………………………………………………………………………………………………………… 2.2 General Safety Instructions …………………………………………………………………………………………… 2.3 Notice For Use ………………………………………………………………………………………………………………… 2.4 Notice for Disposal ……………………………………………………………………………………………………………… 3. Overview ………………………………………………………………………………………………………………………………...
  • Page 3: Introduction

    1.1 Product Description 1.2 Packaging Solis S6 Mini Single Phase Inverter integrate DRM and backflow power control When you receive the inverter, please ensure that all the parts listed below are included: function, that could suitable for smart grid requirement.
  • Page 4: Product Storage

    1. Introduction 2. Safety Instructions 1.3 Product Storage 2.1 Safety Symbols If the inverter is not to be installed immediately, storage instructions and environmental Safety symbols used in this manual, which highlight potential safety risks and important conditions are below: safety information, are listed as follows: Use the original box to repackage the inverter, seal with adhesive tape with the desiccant inside the box.
  • Page 5: Notice For Use

    Do not touch any inner live parts until 5 minutes after disconnection from Solis and the grid operator. the utility grid and the PV input. 4. Use Solis products only in accordance with the information provided in the enclosed CAUTION: documentation and with the locally applicable laws, regulations, standards and Risk of electric shock.
  • Page 6: Overview

    3. Overview 4. Installation 3.1 Front Panel Display 4.1 Select a Location for the Inverter To select a location for the inverter, the following criteria should be considered: WARNING: Risk of fire Despite careful construction, electrical devices can cause fires. Do not install the inverter in areas containing highly flammable materials or gases.
  • Page 7: Mounting The Inverter

    4. Installation 4. Installation 4.2 Mounting the Inverter Install on a wall or strong structure capable of bearing the weight. Dimensions of mounting bracket: Install vertically with a maximum incline of +/- 5°.If the mounted inverter is tilted to an angle greater than the maximum noted, heat dissipation can be inhibited, and may result in less than expected output power.
  • Page 8: Electrical Connections

    4. Installation 4. Installation 4.3 Electrical Connections Inverter designs quick-connect terminal, so top cover needn't open during electrical connection. The sign meaning located the bottom of inverter, as shown below in table 4.1. WARNING: All electrical connections are suit for the local or national standard. The inverter must be mounted vertically.
  • Page 9 4. Installation 4. Installation Crimping plier Figure 4.10 Figure 4.11 Crimp the contact pin to the wire Connector with Cap nut Screwed on Figure 4.6 DC+ Connector Figure 4.7 DC- Connector Please use approved DC cable for PV system. Cross section(mm²) Cable type Range Recommended value...
  • Page 10 Figure 4.16 Connect Wires to the Terminal Figure 4.13 AC Grid Terminal Connector Inside 3. Insert Seal and Clamp Finger into body ,then tighten the nut, torque 2.5+/-0.5N·m. Each Solis S6 Mini Single Phase Inverter is supplied with an AC grid terminal connector. Claw Body...
  • Page 11 Prepare OT terminals: M4. Use proper tooling to crimp the lug to the terminal. The inverter can be monitored via Wi-Fi or GPRS. All Solis communication devices are Connect the OT terminal with ground cable to the right side of inverter. The torque is 2N.m.
  • Page 12 Load External CT Type Meter - 120A/40mA CT is supplied (Model: ACR10RD16TE) Customer can place the order for a suitable meter from Solis Sales Reps. Figure 4.23 Direct Insert Type Meter - “Meter in Load” Below are the connection diagrams of different meters connecting to different locations.
  • Page 13 INV PE Grid PE NOTE: Please contact Solis sales rep to order the CT. 100A/33.33mA (Hole Figure 4.24 External CT Type Meter - “Meter in Grid” Diameter: 16mm) CT with the connector can be ordered from Solis. If the size is not suitable for specific project installation, customer can...
  • Page 14: Start & Stop

    1. Select "Grid Off" in the Advanced Setting of Inverter LCD. 1--8 Rj45 plug 2. Turn off the AC Switch between Solis inverter and Grid. Correspondence between the cable s Rj45terminal and the stitch es of plug, Pin5 and Pin6 3.
  • Page 15: Operation

    NULL 10 sec DRM Number: The Solis S6 Mini Single Phase Inverter main menu provides access to operational data and DRM Number:Show the number 01-08. information. The information is displayed by selecting "Information" from the menu and then by scrolling up or down.
  • Page 16: Settings

    This function is used to set the address when muti inverters are connected to single monitor. The address number can be assigned from “01”to “99”. Alarm001: OV-G-V The default address number of Solis S6 Mini Single Phase Inverter is “01”. Time: 00-00 Data: 7171 YES=<ENT>...
  • Page 17 6. Operation 6. Operation 6.4.3 Version 6.4.6 Yearly Energy The screen shows the model version and the software version of the Inverter The function is for checking the energy generation for selected year. Model: 08 YES=<ENT> NO=<ESC> Software Version: D20001 Select: 2020 Figure 6.7 Model Version and Software Version...
  • Page 18: Advanced Settings

    6.5.2 Grid ON/OFF Press the UP/DOWN keys to select the standard (AS4777-02,AS4777-15, VDE4105, VDE0126, This function is used to start up or stop the power generation of Solis Single Phase Inverter. UL-240V-A, UL-208V-A, UL-240V, UL-208V, MEX-CFE, G83/2 (for 1-3.6kW models), G59/3 (for 4-5kW models), C10/11, EN50438 DK, EN50438 IE, EN50438 NL and “User-Def”...
  • Page 19 Until the sunrise, the system will start to work again while the meter data can be uploaded to the Solis monitoring system 6.5.7 Calibrate Energy to calibrate the load consumption data.
  • Page 20 EPM OFF: Energy power management Functions are disabled 1. Select Initial Settings Meter in Load: Solis Smart Meter is connected in the load branch circuit, and the function is 2. Select DRM and set it “ON” to use the smart meter conduct export power control and load monitoring Meter in Grid: Solis Smart Meter is connected in the grid connection point.
  • Page 21 Scenario2: 24 Hours Consumption load Monitoring function by Smart (If necessary). Meter. Step 7: Configure the Solis monitoring system (Please refer to the manual Step 1: Refer to Section 4.3.7 to connect the smart meter on the grid side. of monitoring device) Step 2: Select the corresponding meter model in Section 6.5.12.4.
  • Page 22 Figure . 6 23 Set the backflow power default CT supplied by Solis. The default CT is 100A:33.33mA (Default ratio is 3000:1) NOTE: Positive values indicate the amount of power is allowed to export to the -> CT Sampling Ratio YES=<ENT>...
  • Page 23: Afci Function

    Others-EPM Failsafe Option should be turned ON when 2G series EPM device is used Only one option can be activated each time. Solis inverters have the built-in AFCI function which can detect the arc fault on the DC circuit 6.5.14 Restart HMI and shut down the inverter to prevent a fire disaster.
  • Page 24: Maintenance

    However, cleaning the dust on heat-sink will help the inverter to dissipate the heat and The "AFCI Level" is reserved for Solis technicians ONLY. Do not change the increase its life time. The dust can be removed with a soft brush.
  • Page 25: Troubleshooting

    IGFOL-F 1.Restart inverter or contact installer. Grid current sampling fail 1. Serial number of Solis Single Phase Inverter; IG-AD 2. The distributor/dealer of Solis Single Phase Inverter (if available); 1.Check inverter surrounding ventilation. 3. Installation date. Over Temperature OV-TEM 2.Check if there’s sunshine direct on inverter in hot weather.
  • Page 26: Specifications

    9. Specifications 9. Specifications Model S6-GR1P0.7K-M Model S6-GR1P1K-M Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Startup voltage (Volts) Startup voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 50...500 50...500 Max.
  • Page 27 9. Specifications 9. Specifications Model S6-GR1P1.5K-M Model S6-GR1P2K-M Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Startup voltage (Volts) Startup voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 50...500 80...500 Max.
  • Page 28 9. Specifications 9. Specifications Model S6-GR1P2.5K-M Model S6-GR1P3K-M Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Startup voltage (Volts) Startup voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 80...500 80...500 Max.
  • Page 29 9. Specifications 9. Specifications Model S6-GR1P3.6K-M Model S6-GR1P0.6K-M(For Germany) Max. DC input voltage (Volts) Max. DC input voltage (Volts) Rated DC voltage (Volts) Rated DC voltage (Volts) Startup voltage (Volts) Startup voltage (Volts) MPPT voltage range (Volts) MPPT voltage range (Volts) 80...500 50...500 Max.